초록
Purpose: This study aimed to determine whether zero echo time magnetic resonance imaging (ZTE-MRI), as an alternative imaging modality, and conventional computed tomography (CT) have similar diagnostic qualities for assessing pediatric osseous pathologies. Materials and Methods: Twenty-six sets of pediatric musculoskeletal CT and MRI scans (15 boys and 11 girls; mean age, 12 ± 4 years; range, 5–23 years) acquired at Seoul National University Children’s Hospital (January 2021 to November 2023) were retrospectively evaluated. CT-like images from ZTE-MRI were generated using grayscale inversion. Two radiologists independently assessed ZTE-MRI image quality (Sanat) on a 5-point scale (1 = nondiagnostic, 5 = excellent) and a comparative scale (–2 = CT greater, 0 = same, 2 = ZTE-MRI greater) for lesion delineation (Scomp). The confidence interval of proportions and intraclass correlation coefficient were calculated to assess inter-rater agreement, and Wilcoxon rank-sum test, Mann–Whitney U test, or paired t-test was used to compare image quality or cortical thickness between the modalities. Results: ZTE-MRI demonstrated diagnostic quality (Sanat ≥ 3) in 85%–96% of the cases, 89%–96% for cortical delineation, 92%–100% for intramedullary cavity (IMC) delineation, and 92% for lesion delineation. Compared with conventional CT, ZTE-MRI showed comparable diagnostic power (Scomp ≥ –1) in 92%–96% of the cases, with Scomp scores indicating no significant difference in lesion delineation (p = 0.53 in reader 1 and p = 0.25 in reader 2). There was a preference for CT over ZTE-MRI in terms of overall image quality and delineation of the cortex and IMC (p < 0.001). Cortical thickness was not significantly different (p = 0.11) between ZTE-MRI and CT. Conclusion: ZTE-MRI demonstrated diagnostic quality comparable to that of CT, particularly in lesion delineation. In addition to the unique information that conventional MRI can provide, ZTE-MRI can provide additional information about osseous structures similar to that provided by CT, which we believe will be valuable in the future.
Abstract
Purpose: This study aimed to determine whether zero echo time magnetic resonance imaging (ZTE-MRI), as an alternative imaging modality, and conventional computed tomography (CT) have similar diagnostic qualities for assessing pediatric osseous pathologies. Materials and Methods: Twenty-six sets of pediatric musculoskeletal CT and MRI scans (15 boys and 11 girls; mean age, 12 ± 4 years; range, 5–23 years) acquired at Seoul National University Children’s Hospital (January 2021 to November 2023) were retrospectively evaluated. CT-like images from ZTE-MRI were generated using grayscale inversion. Two radiologists independently assessed ZTE-MRI image quality (Sanat) on a 5-point scale (1 = nondiagnostic, 5 = excellent) and a comparative scale (–2 = CT greater, 0 = same, 2 = ZTE-MRI greater) for lesion delineation (Scomp). The confidence interval of proportions and intraclass correlation coefficient were calculated to assess inter-rater agreement, and Wilcoxon rank-sum test, Mann–Whitney U test, or paired t-test was used to compare image quality or cortical thickness between the modalities. Results: ZTE-MRI demonstrated diagnostic quality (Sanat ≥ 3) in 85%–96% of the cases, 89%–96% for cortical delineation, 92%–100% for intramedullary cavity (IMC) delineation, and 92% for lesion delineation. Compared with conventional CT, ZTE-MRI showed comparable diagnostic power (Scomp ≥ –1) in 92%–96% of the cases, with Scomp scores indicating no significant difference in lesion delineation (p = 0.53 in reader 1 and p = 0.25 in reader 2). There was a preference for CT over ZTE-MRI in terms of overall image quality and delineation of the cortex and IMC (p < 0.001). Cortical thickness was not significantly different (p = 0.11) between ZTE-MRI and CT. Conclusion: ZTE-MRI demonstrated diagnostic quality comparable to that of CT, particularly in lesion delineation. In addition to the unique information that conventional MRI can provide, ZTE-MRI can provide additional information about osseous structures similar to that provided by CT, which we believe will be valuable in the future.
참고문헌 (23)
- Du J, "Assessment of cortical bone with clinical and ultrashort echo time sequences", Magn Reson Med, 70, pp.697~704 (2013)
- Wehrli FW, "Quantitative MRI for the assessment of bone structure and function", NMR Biomed, 19, pp.731~764 (2006)
- Du J, "Qualitative and quantitative ultrashort echo time(UTE)imaging of cortical bone", J Magn Reson, 207, pp.304~311 (2010)
- Weiger M, "MRI with zero echo time", eMagRes, 1, pp.311~322 (2012)
- Weiger M, "ZTE imaging in humans", Magn Reson Med, 70, pp.328~332 (2013)
- Froidevaux R, "High-resolution short-T2 MRI using a high-performance gradient", Magn Reson Med, 84, pp.1933~1946 (2020)
- Sandberg JK, "Zero echo time pediatric musculoskeletal magnetic resonance imaging : initial experience", Pediatr Radiol, 51, pp.2549~2560 (2021)
- Koff MF, "Correlation of meniscal T2*with multiphoton microscopy, and change of articular cartilage T2 in an ovine model of meniscal repair", Osteoarthritis Cartilage, 21, pp.1083~1091 (2013)
- Bae WC, "Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk", Top Magn Reson Imaging, 21, pp.275~289 (2010)
- Chang EY, "Quantitative bicomponent T2* analysis of histologically normal Achilles tendons", Muscles Ligaments Tendons J, 5, pp.58~62 (2015)
- Bae K, "Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences : preliminary study", Eur Radiol, 29, pp.2253~2262 (2019)
- Beenakker JM, "Silent volumetric multi-contrast 7 tesla MRI of ocular tumors using zero echo time imaging", PLoS One, 14, pp.e0222573~ (2019)
- Breighner RE, "Technical developments : zero echo time imaging of the shoulder : enhanced osseous detail by using MR imaging", Radiology, 286, pp.960~966 (2018)
- Breighner RE, "Evaluation of osseous morphology of the hip using zero echo time magnetic resonance imaging", Am J Sports Med, 47, pp.3460~3468 (2019)
- Lee C, "CT-like MRI using the zero-TE technique for osseous changes of the TMJ", Dentomaxillofac Radiol, 49, pp.20190272~ (2020)
- Argentieri EC, "Diagnostic accuracy of zero-echo time MRI for the evaluation of cervical neural foraminal stenosis", Spine(Phila Pa 1976), 43, pp.928~933 (2018)
- Cho SB, "Clinical feasibility of zero TE skull MRI in patients with head trauma in comparison with CT : a single-center study", AJNR Am J Neuroradiol, 40, pp.109~115 (2019)
- Koo TK, "A guideline of selecting and reporting intraclass correlation coefficients for reliability research", J Chiropr Med, 15, pp.155~163 (2016)
- Aydıngöz Ü, "Zero echo time musculoskeletal MRI : technique, optimization, applications, and pitfalls", Radiographics, 42, pp.1398~1414 (2022)
- Alibek S, "Acoustic noise reduction in MRI using Silent Scan : an initial experience", Diagn Interv Radiol, 20, pp.360~363 (2014)
- Lu A, "Zero TE MRI for craniofacial bone imaging", AJNR Am J Neuroradiol, 40, pp.1562~1566 (2019)
- Heindel W, "Artifacts in MR imaging after surgical intervention", J Comput Assist Tomogr, 10, pp.596~599 (1986)
- Arena L, "MR imaging artifacts that simulate disease : how to recognize and eliminate them", Radiographics, 15, pp.1373~1394 (1995)