초록

Ultrashort echo time (UTE) and zero echo time (ZTE) imaging sequences have been developed to detect short T2 relaxation signals emanating from regions or tissues that conventional magnetic resonance imaging (MRI) methods fail to capture. Owing to the high dipole– dipole interactions in solid and semisolid tissues, the signal decay occurs very rapidly, typically in less than 1 ms. The echo time generated by conventional imaging methods is insufficiently short, resulting in void signals from these short-T2 species. The application of UTE and ZTE techniques enables the imaging of solid and semi-solid tissues, making the conventionally invisible visible, which can significantly impact clinical imaging. Highand ultra-high-field-strength (UHF) MRI offers a critical advantage in enhancing the sensitivity and specificity of MRI. When combined with UTE and ZTE sequences, it enables the recovery of signals from void areas and markedly improves signal quality. To bolster this approach and further validate the technique, while addressing its limitations, extensive efforts have been made to collect supplementary data using various research tools. Studies demonstrate that integrating UTE and ZTE sequences with advanced high and ultra-high field imaging techniques—particularly innovative developments in transmit/receive hardware, software, and novel trajectory approaches—plays a pivotal role in enhancing the clarity and accuracy of MRI for musculoskeletal, neural, lung, and dental applications.

Abstract

Ultrashort echo time (UTE) and zero echo time (ZTE) imaging sequences have been developed to detect short T2 relaxation signals emanating from regions or tissues that conventional magnetic resonance imaging (MRI) methods fail to capture. Owing to the high dipole– dipole interactions in solid and semisolid tissues, the signal decay occurs very rapidly, typically in less than 1 ms. The echo time generated by conventional imaging methods is insufficiently short, resulting in void signals from these short-T2 species. The application of UTE and ZTE techniques enables the imaging of solid and semi-solid tissues, making the conventionally invisible visible, which can significantly impact clinical imaging. Highand ultra-high-field-strength (UHF) MRI offers a critical advantage in enhancing the sensitivity and specificity of MRI. When combined with UTE and ZTE sequences, it enables the recovery of signals from void areas and markedly improves signal quality. To bolster this approach and further validate the technique, while addressing its limitations, extensive efforts have been made to collect supplementary data using various research tools. Studies demonstrate that integrating UTE and ZTE sequences with advanced high and ultra-high field imaging techniques—particularly innovative developments in transmit/receive hardware, software, and novel trajectory approaches—plays a pivotal role in enhancing the clarity and accuracy of MRI for musculoskeletal, neural, lung, and dental applications.

참고문헌 (175)

  1. Lauterbur PC, "Image formation by induced local interactions : examples employing nuclear magnetic resonance", Nature, 242, pp.190~191 (1973)
  2. Mansfield P, "Multi-planar image formation using NMR spin echoes", J Phys C Solid State Phys, 10, pp.L55~ (1977)
  3. Ladd ME, "Pros and cons of ultrahigh-field MRI", MRS for human application, 2018, pp.109, 1~50
  4. Qi S, "Cortical inhibition deficits in recent onset PTSD after a single prolonged trauma exposure", Neuroimage Clin, 3, pp.226~233 (2013)
  5. Liu LP, "Diagnostic performance of diffusion-weighted magnetic resonance imaging in bone malignancy:evidence from a meta-analysis", Medicine(Baltimore), 94, pp.e1998~ (2015)
  6. Zhang J, "Decreased gray matter volume in the left hippocampus and bilateral calcarine cortex in coal mine flood disaster survivors with recent onset PTSD", Psychiatry Res, 192, pp.84~90 (2011)
  7. Ug˘urbil K, "Imaging at high magnetic fields : initial experiences at 4 T", Magn Reson Q, 9, pp.259~277 (1993)
  8. Zhang X, "High resolution imaging of the human head at 8 tesla", Proceedings of the 16th Annual Meeting of the ESMRMB, pp.44~ (1999)
  9. Ug˘ urbil K, "Magnetic resonance studies of brain function and neurochemistry", Annu Rev Biomed Eng, 2, pp.633~660 (2000)
  10. Zhang X, "Microstrip RF surface coil design for extremely high-field MRI and spectroscopy", Magn Reson Med, 46, pp.443~450 (2001)
  11. Zhang X, "Microstrip RF surface coils for human MRI studies at 7 tesla", Proceedings of the 9th Annual Meeting of ISMRM, pp.1104~ (2001)
  12. Zhang X, "A new RF volume coil for human MR imaging and spectroscopy at 4 tesla", Proceedings of the 9th Annual Meeting of ISMRM, pp.1103~ (2001)
  13. Zhu XH, "Probing fast neuronal interaction in the human ocular dominate columns based on fMRI BOLD response at 7 tesla", Proceedings of the 9th Annual Meeting of ISMRM, pp.287~ (2001)
  14. Zhu X, "A 400 MHz flexible MTL RF coil using the 2nd harmonic resonance for rat MR imaging at 9.4T", Proceedings of the 10th Annual Meeting of ISMRM, pp.159~ (2002)
  15. Qiao H, "In vivo 31P MRS of human brain at high", ultrahigh fields : a quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T, 2006, pp.24, 1281~1286
  16. Zhang X, "A microstrip transmission line volume coil for human head MR imaging at 4T", J Magn Reson, 161, pp.242~251 (2003)
  17. Zhang X, "Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined(REDE)implanted vascular RF coil", MAGMA, 16, pp.77~85 (2003)
  18. "Method and apparatus for magnetic resonance imaging and spectroscopy using microstrip transmission line coils (publication: US20060006865A1, application:US11/224,436)"[URL]
  19. Zhang X, "An inverted-microstrip resonator for human head proton MR imaging at 7 tesla", IEEE Trans Biomed Eng, 52, pp.495~504 (2005)
  20. Zhang X, "Higher-order harmonic transmission-line RF coil design for MR applications", Magn Reson Med, 53, pp.1234~1239 (2005)
  21. Lei H, "In vivo 31P magnetic resonance spectroscopy of human brain at 7 T : an initial experience", Magn Reson Med, 49, pp.199~205 (2003)
  22. "Method and apparatus for magnetic resonance imaging and spectroscopy using microstrip transmission line coils (publication: US7023209B2, application:US09/974,184)"[URL]
  23. "Method and apparatus for magnetic resonance imaging and spectroscopy using multiple-mode coils (publication:US20110074422A1, application: US12/990,541)"[URL]
  24. Zhu XH, "Advanced in vivo heteronuclear MRS approaches for studying brain bioenergetics driven by mitochondria", Methods Mol Biol, 489, pp.317~357 (2009)
  25. Dafni H, "Hyperpolarized 13C spectroscopic imaging informs on hypoxia-inducible factor-1 and myc activity downstream of platelet-derived growth factor receptor", Cancer Res, 70, pp.7400~7410 (2010)
  26. Moser E, "Ultra-high-field magnetic resonance : why and when?", World J Radiol, 2, pp.37~40 (2010)
  27. Pang Y, "Interpolated compressed sensing MR image reconstruction using neighboring slice k-space data", Proceedings of the 20th Annual Meeting of ISMRM, pp.2275~ (2002)
  28. Pang Y, "Interpolated compressed sensing for 2D multiple slice fast MR imaging", PLoS One, 8, pp.e56098~ (2013)
  29. Zhang X, "Human extremity imaging using microstrip resonators at 7T", Proceedings of the 21st Annual Meeting of ISMRM, pp.1675~ (2013)
  30. Wang YX, "Magnetic resonance imaging for lung cancer screen", J Thorac Dis, 6, pp.1340~1348 (2014)
  31. Milshteyn E, "The need and initial practice of parallel imaging and compressed sensing in hyperpolarized 13C MRI in vivo", OMICS J Radiol, 4, pp.e133~ (2015)
  32. Zhang X, "Sensitivity enhancement of traveling wave MRI using free local resonators : an experimental demonstration", Quant Imaging Med Surg, 7, pp.170~176 (2017)
  33. Wei Z, "5T magnetic resonance imaging : radio frequency hardware and initial brain imaging", Quant Imaging Med Surg, 13, pp.3222~3240 (2023)
  34. Zhang X, "A wrap-on decoupled coaxial transmission line(CTL)transceive array for head MR imaging at 10. 5T", Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib, 31, pp.3904~ (2023)
  35. Zhang X, "Design and test of a flexible two-row CTL array and its detunable resonant elements for 10. 5T MR imaging", Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib, 31, pp.4593~ (2023)
  36. Payne K, "Double cross magnetic wall decoupling for quadrature transceiver RF array coils using common-mode differential-mode resonators", J Magn Reson, 353, pp.107498~ (2023)
  37. Rutledge O, "Design and test of a double-nuclear RF coil for(1)H MRI and(13)C MRSI at 7T", J Magn Reson, 267, pp.15~21 (2016)
  38. Hoult DI, "The signal-to-noise ratio of the nuclear magnetic resonance experiment", J Magn Reson(1969), 24, pp.71~85 (1976)
  39. Ackerman JJ, "Mapping of metabolites in whole animals by 31P NMR using surface coils", Nature, 283, pp.167~170 (1980)
  40. Chen CN, "The field dependence of NMR imaging. I. Laboratory assessment of signal-to-noise ratio and power deposition", Magn Reson Med, 3, pp.722~729 (1986)
  41. Hoult DI, "Sensitivity and power deposition in a high-field imaging experiment", J Magn Reson Imaging, 12, pp.46~67 (2000)
  42. Zhang X, "Experimental design of transmission line volume RF coil for MR imaging at 8T", Proceedings of the 8th Scientific Meeting & Exhibition of the International Society for Magnetic Resonance in Medicine, pp.150~ (2000)
  43. Zhang X, "Novel radio frequency resonators for in vivo magnetic resonance imaging and spectroscopy at very high magnetic fields", pp.2002
  44. Zhu XH, "Development of(17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field", Proc Natl Acad Sci U S A, 99, pp.13194~13199 (2002)
  45. Wang C, "Evaluation of B1+ and E field of RF resonator with high dielectric insert", Proceedings of the 17th Annual Meeting of ISMRM, pp.3054~ (2009)
  46. Wu B, "Multi-reception strategy with improved SNR for multichannel MR imaging", PLoS One, 7, pp.e42237~ (2012)
  47. Kurhanewicz J, "Hyperpolarized 13C MRI : path to clinical translation in oncology", Neoplasia, 21, pp.1~16 (2019)
  48. Vaughan JT, "7T vs. 4T : RF power, homogeneity, and signal-to-noise comparison in head images", Magn Reson Med, 46, pp.24~30 (2001)
  49. Hoult DI, "The principle of reciprocity in signal strength calculations—a mathematical guide", Concept Magn Reson, 12, pp.173~187 (2000)
  50. Collins CM, "Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz", Magn Reson Med, 47, pp.1026~1028 (2002)
  51. Yang QX, "Analysis of wave behavior in lossy dielectric samples at high field", Magn Reson Med, 47, pp.982~989 (2002)
  52. Adriany G, "Transmit and receive transmission line arrays for 7 tesla parallel imaging", Magn Reson Med, 53, pp.434~445 (2005)
  53. Zhang X, "A dual-tuned microstrip volume coil array for human head parallel 1H", 31P MRI, 11th Scientific Meeting and Exhibition of ISMRM, pp.2005[DOI]
  54. Yang QX, "Manipulation of image intensity distribution at 7. 0 T : passive RF shimming and focusing with dielectric materials", J Magn Reson Imaging, 24, pp.197~202 (2006)
  55. Wu B, "Capacitively decoupled tunable loop microstrip(TLM)array at 7 T", Magn Reson Imaging, 25, pp.418~424 (2007)
  56. Xie Z, "A novel decoupling technique for non-overlapped microstrip array coil at 7T MR imaging", Proceedings of the 16th Annual Meeting of the International Society of Magnetic Resonance in Medicine, pp.1068~ (2008)
  57. Xie Z, "An 8-channel non-overlapped spinal cord array coil for 7T MR imaging", Proceedings of the 16th Annual Meeting of the International Society of Magnetic Resonance in Medicine, pp.2974~ (2008)
  58. Xie Z, "An 8-channel microstrip array coil for mouse parallel MR imaging at 7T by using magnetic wall decoupling technique", Proceedings of the 17th Annual Meeting of ISMRM, pp.2973~ (2009)
  59. Li Y, "Common-mode differential-mode(CMDM)method for quadrature transmit", receive surface coil for ultrahigh field MRI, 2011, 1858~
  60. Li Y, "ICE decoupling technique for RF coil array designs", Med Phys, 38, pp.4086~4093 (2011)
  61. Lu J, "Evaluation of common RF coil setups for MR imaging at ultrahigh magnetic field : a numerical study", Int Symp Appl Sci Biomed Commun Technol, 2011, pp.70~ (2011)
  62. Pang Y, "Numerical analysis of human sample effect on RF penetration and liver MR imaging at ultrahigh field", Concepts Magn Reson Part B Magn Reson Eng, 39B, pp.206~216 (2011)
  63. Pang Y, "Precompensation for mutual coupling between array elements in parallel excitation", Quant Imaging Med Surg, 1, pp.4~10 (2011)
  64. Pang Y, "Common-mode differential-mode(CMDM)method for double-nuclear MR signal excitation and reception at ultrahigh fields", IEEE Trans Med Imaging, 30, pp.1965~1973 (2011)
  65. Subburaj K, "A flexible microstrip transceiver coil for imaging flexed human knee joints at 7 tesla", Proceedings of the 19th Annual Meeting of ISMRM, pp.3821~ (2011)
  66. Pang Y, "Parallel traveling-wave MRI : a feasibility study", Magn Reson Med, 67, pp.965~978 (2012)
  67. Pang Y, "A dual-tuned quadrature volume coil with mixed λ", 2 and λ, Magn Reson Imaging, pp.2012, 30[DOI]
  68. Wang C, "A practical multinuclear transceiver volume coil for in vivo MRI", MRS at 7 T, 2012, pp.30, 78~84
  69. Li Y, "Image homogenization using pre-emphasis method for high field MRI", Quant Imaging Med Surg, 3, pp.217~223 (2013)
  70. Hu X, "Parallel imaging performance investigation of an 8-channel common-mode differential-mode(CMDM)planar array for 7T MRI", Quant Imaging Med Surg, 4, pp.33~42 (2014)
  71. Li Y, "Planar quadrature RF transceiver design using common-mode differential-mode(CMDM)transmission line method for 7T MR imaging", PLoS One, 8, pp.e80428~ (2013)
  72. Pang Y, "Tilted microstrip phased arrays with improved electromagnetic decoupling for ultrahigh-field magnetic resonance imaging", Medicine(Baltimore), 93, pp.e311~ (2014)
  73. Yan X, "A monopole", loop dual-tuned RF coil for ultrahigh field MRI, 2014, pp.4, 225~231
  74. Yan X, "Hybrid monopole", loop coil array for human head MR imaging at 7T, 2015, pp.46, 541~550
  75. Yan X, "Decoupling and matching network for monopole antenna arrays in ultrahigh field MRI", Quant Imaging Med Surg, 5, pp.546~551 (2015)
  76. Yan X, "Eight-channel monopole array using ICE decoupling for human head MR imaging at 7 T", Appl Magn Reson, 47, pp.527~538 (2016)
  77. Yan X, "Closely-spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields", Appl Magn Reson, 46, pp.1239~1248 (2015)
  78. Yan X, "Simulation verification of SNR and parallel imaging improvements by ICE-decoupled loop array in MRI", Appl Magn Reson, 47, pp.395~403 (2016)
  79. Wu B, "Shielded microstrip array for 7T human MR imaging", IEEE Trans Med Imaging, 29, pp.179~184 (2010)
  80. Wu B, "7T human spine imaging arrays with adjustable inductive decoupling", IEEE Trans Biomed Eng, 57, pp.397~403 (2010)
  81. Wu B, "Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans", IEEE Trans Med Imaging, 31, pp.183~191 (2012)
  82. Wu B, "Flexible transceiver array for ultrahigh field human MR imaging", Magn Reson Med, 68, pp.1332~1338 (2012)
  83. Payne K, "Hairpin RF resonators for MR imaging transceiver arrays with high inter-channel isolation and B1efficiency at ultrahigh field 7 T", J Magn Reson, 345, pp.107321~ (2022)
  84. Payne K, "Dual-tuned coaxialtransmission-line RF coils for hyperpolarized 13C and deuterium 2H metabolic MRS imaging at ultrahigh fields", IEEE Trans Biomed Eng, 71, pp.1521~1530 (2024)
  85. Yan X, "Magnetic wall decoupling method for monopole coil array in ultrahigh field MRI : a feasibility test", Quant Imaging Med Surg, 4, pp.79~86 (2014)
  86. Li C, "Magnetic resonance imaging of short-T2 tissues with applications for quantifying cortical bone water and myelin", pp.2014
  87. Wu Z, "Assessment of ultrashort echo time(UTE)T2* mapping at 3T for the whole knee : repeatability, the effects of fat suppression, and knee position", Quant Imaging Med Surg, 13, pp.7893~7909 (2023)
  88. Pauly JM, "Suppression of long-T2components for short-T2 imaging", Proceedings of the 10th Annual Meeting of SMRI, pp.330~ (1992)
  89. Weiger M, "MRI with zero echo time", eMagRes, 1, pp.311~321 (2012)
  90. Larson PE, "Ultrashort echo time and zero echo time MRI at 7T", MAGMA, 29, pp.359~370 (2016)
  91. Tyler DJ, "Magnetic resonance imaging with ultrashort TE(UTE)PULSE sequences : technical considerations", J Magn Reson Imaging, 25, pp.279~289 (2007)
  92. Ma YJ, "Quantitative ultrashort echo time(UTE)magnetic resonance imaging of bone : an update", Front Endocrinol(Lausanne), 11, pp.567417~ (2020)
  93. Fabich HT, "Ultrashort echo time(UTE)imaging using gradient pre-equalization and compressed sensing", J Magn Reson, 245, pp.116~124 (2014)
  94. Li C, "Correction of excitation profile in zero echo time(ZTE)imaging using quadratic phase-modulated RF pulse excitation and iterative reconstruction", IEEE Trans Med Imaging, 33, pp.961~969 (2014)
  95. Juras V, "Regional variations of T2* in healthy and pathologic Achilles tendon in vivo at 7 tesla : preliminary results", Magn Reson Med, 68, pp.1607~1613 (2012)
  96. Wu Y, "Water-and fat-suppressed proton projection MRI(WASPI)of rat femur bone", Magn Reson Med, 57, pp.554~567 (2007)
  97. Zhao X, "Feasibility of assessing bone matrix and mineral properties in vivo by combined solid-state 1H and 31P MRI", PLoS One, 12, pp.e0173995~ (2017)
  98. Du J, "Dual inversion recovery, ultrashort echo time(DIR UTE)imaging : creating high contrast for short-T2 species", Magn Reson Med, 63, pp.447~455 (2010)
  99. Idiyatullin D, "Fast and quiet MRI using a swept radiofrequency", J Magn Reson, 181, pp.342~349 (2006)
  100. Idiyatullin D, "Multi-band-SWIFT", J Magn Reson, 251, pp.19~25 (2015)
  101. Herrmann KH, "Time efficient 3D radial UTE sampling with fully automatic delay compensation on a clinical 3T MR scanner", PLoS One, 11, pp.e0150371~ (2016)
  102. Han M, "Depiction of Achilles tendon microstructure in vivo using high-resolution 3-dimensional ultrashort echo-time magnetic resonance imaging at 7 T", Invest Radiol, 49, pp.339~345 (2014)
  103. Du J, "Two-dimensional ultrashort echo time imaging using a spiral trajectory", Magn Reson Imaging, 26, pp.304~312 (2008)
  104. Wan L, "Fast quantitative three-dimensional ultrashort echo time(UTE)cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling", NMR Biomed, 33, pp.e4376~ (2020)
  105. Qian Y, "High-resolution spiral imaging on a whole-body 7T scanner with minimized image blurring", Magn Reson Med, 63, pp.543~552 (2010)
  106. Li C, "Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI", Magn Reson Med, 68, pp.680~689 (2012)
  107. Weiger M, "ZTE imaging in humans", Magn Reson Med, 70, pp.328~332 (2013)
  108. Breighner RE, "Technical developments : zero echo time imaging of the shoulder : enhanced osseous detail by using MR imaging", Radiology, 286, pp.960~966 (2018)
  109. Schieban K, "ZTE imaging with enhanced flip angle using modulated excitation", Magn Reson Med, 74, pp.684~693 (2015)
  110. Chang EY, "UTE imaging in the musculoskeletal system", J Magn Reson Imaging, 41, pp.870~883 (2015)
  111. Krug R, "Ultrashort echo time MRI of cortical bone at 7 tesla field strength : a feasibility study", J Magn Reson Imaging, 34, pp.691~695 (2011)
  112. Yang J, "Quantitative ultrashort echo time magnetization transfer(UTE-MT)for diagnosis of early cartilage degeneration : comparison with UTE-T2* and T2 mapping", Quant Imaging Med Surg, 10, pp.171~183 (2020)
  113. Dournes G, "The clinical use of lung MRI in cystic fibrosis : what, now, how?", Chest, 159, pp.2205~2217 (2021)
  114. Stock KW, "Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times", Magn Reson Imaging, 17, pp.997~1000 (1999)
  115. Johnson KM, "Optimized 3D ultrashort echo time pulmonary MRI", Magn Reson Med, 70, pp.1241~1250 (2013)
  116. Kuethe DO, "Imaging lungs using inert fluorinated gases", Magn Reson Med, 39, pp.85~88 (1998)
  117. Weiger M, "Rapid and robust pulmonary proton ZTE imaging in the mouse", NMR Biomed, 27, pp.1129~1134 (2014)
  118. Guo J, "Murine pulmonary imaging at 7T : T2* and T1 with anisotropic UTE", Magn Reson Med, 79, pp.2254~2264 (2018)
  119. Gai ND, "Three-dimensional T1 and T2* mapping of human lung parenchyma using interleaved saturation recovery with dual echo ultrashort echo time imaging(ITSR-DUTE)", J Magn Reson Imaging, 45, pp.1097~1104 (2017)
  120. Schraml C, "Non-invasive pulmonary perfusion assessment in young patients with cystic fibrosis using an arterial spin labeling MR technique at 1. 5 T", MAGMA, 25, pp.155~162 (2012)
  121. Kobayashi N, "SWIFT MRI enhances detection of breast cancer metastasis to the lung", Magn Reson Med, 73, pp.1812~1819 (2015)
  122. Park J, "A robust self-navigation for respiratory gating in 3D radial ultrashort echo-time lung MRI using concurrent dephasing and excitation", J Korean Phys Soc, 73, pp.138~144 (2018)
  123. Feng L, "XD-GRASP : golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing", Magn Reson Med, 75, pp.775~788 (2016)
  124. Heidenreich JF, "Three-dimensional ultrashort echo time MRI for functional lung imaging in cystic fibrosis", Radiology, 296, pp.191~199 (2020)
  125. Ding Z, "Dynamic pulmonary MRI using motion-state weighted motion-compensation(MostMoCo)reconstruction with ultrashort TE : a structural and functional study", Magn Reson Med, 88, pp.224~238 (2022)
  126. Hövener JB, "Dental MRI : imaging of soft and solid components without ionizing radiation", J Magn Reson Imaging, 36, pp.841~846 (2012)
  127. Mastrogiacomo S, "Magnetic resonance imaging of hard tissues and hard tissue engineered bio-substitutes", Mol Imaging Biol, 21, pp.1003~1019 (2019)
  128. Idiyatullin D, "Dental magnetic resonance imaging : making the invisible visible", J Endod, 37, pp.745~752 (2011)
  129. Wilhelm MJ, "Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin density", Proc Natl Acad Sci U S A, 109, pp.9605~9610 (2012)
  130. Jang H, "Inversion recovery ultrashort TE MR imaging of myelin is significantly correlated with disability in patients with multiple sclerosis", AJNR Am J Neuroradiol, 42, pp.868~874 (2021)
  131. Inoue A, "Clinical utility of new threedimensional model using a zero-echo-time sequence in endoscopic endonasal transsphenoidal surgery", Clin Neurol Neurosurg, 190, pp.105743~ (2020)
  132. Horch RA, "Origins of the ultrashort-T2 1H NMR signals in myelinated nerve : a direct measure of myelin content?", Magn Reson Med, 66, pp.24~31 (2011)
  133. Nelson F, "3D MPRAGE improves classification of cortical lesions in multiple sclerosis", Mult Scler, 14, pp.1214~1219 (2008)
  134. Chen Y, "Imaging of the spinal cord in multiple sclerosis : past, present, future", Brain Sci, 10, pp.857~ (2020)
  135. Du J, "Ultrashort echo time(UTE)magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner", Neuroimage, 87, pp.32~41 (2014)
  136. Ma YJ, "Ultrashort echo time(UTE)magnetic resonance imaging of myelin : technical developments and challenges", Quant Imaging Med Surg, 10, pp.1186~1203 (2020)
  137. Guglielmetti C, "Longitudinal evaluation of demyelinated lesions in a multiple sclerosis model using ultrashort echo time magnetization transfer(UTE-MT)imaging", Neuroimage, 208, pp.116415~ (2020)
  138. Ma Y, "Three-dimensional inversion recovery ultrashort echo time(3D IR-UTE)magnetic resonance imaging of myelin in rats and mice subject to cuprizone treatment", Joint Annual Meeting ISMRM-ESMRMB, pp.1849~ (2018)
  139. Theysohn JM, "7 tesla MRI of microbleeds and white matter lesions as seen in vascular dementia", J Magn Reson Imaging, 33, pp.782~791 (2011)
  140. Afsahi AM, "High-contrast lumbar spinal bone imaging using a 3D slab-selective UTE sequence", Front Endocrinol(Lausanne), 12, pp.800398~ (2022)
  141. Karnik A, "Quantitative susceptibility mapping(QSM)using highresolution ultra-short echo time(UTE)MRI with rosette k-space pattern", Joint Annual Meeting ISMRM-ESMRMB & ISMRT 31st Annual Meeting, pp.1982~ (2022)
  142. Lu X, "Ultrashort echo time quantitative susceptibility mapping(UTE-QSM)of highly concentrated magnetic nanoparticles : a comparison study about different sampling strategies", Molecules, 24, pp.1143~ (2019)
  143. Horch RA, "RF coil considerations for short-T2 MRI", Magn Reson Med, 64, pp.1652~1657 (2010)
  144. Candès EJ, "Robust uncertainty principles : exact signal reconstruction from highly incomplete frequency information", IEEE Trans Inf Theory, 52, pp.489~509 (2006)
  145. Donoho DL, "Compressed sensing", IEEE Trans Inf Theory, 52, pp.1289~1306 (2006)
  146. Hestenes MR, "Methods of conjugate gradients for solving linear systems", J Res Natl Bur Stand, 49, pp.409~435 (1952)
  147. Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
  148. Griswold MA, "Generalized autocalibrating partially parallel acquisitions(GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
  149. Robson MD, "Clinical ultrashort echo time imaging of bone and other connective tissues", NMR Biomed, 19, pp.765~780 (2006)
  150. Pai A, "A comparative study at 3 T of sequence dependence of T2 quantitation in the knee", Magn Reson Imaging, 26, pp.1215~1220 (2008)
  151. Desrochers J, "Depth-dependent changes in cartilage T2 under compressive strain : a 7T MRI study on human knee cartilage", Osteoarthritis Cartilage, 28, pp.1276~1285 (2020)
  152. Filho GH, "Quantitative characterization of the Achilles tendon in cadaveric specimens : T1 and T2* measurements using ultrashort-TE MRI at 3 T", AJR Am J Roentgenol, 192, pp.W117~W124 (2009)
  153. Wurnig MC, "Characterization of trabecular bone density with ultra-short echo-time MRI at 1. 5, 3. 0 and 7. 0 T--comparison with micro-computed tomography", NMR Biomed, 27, pp.1159~1166 (2014)
  154. Okuda M, "Quantitative differentiation of tendon and ligament using magnetic resonance imaging ultrashort echo time T2* mapping of normal knee joint", Acta Radiol, 63, pp.1489~1496 (2022)
  155. Monu UD, "Cluster analysis of quantitative MRI T2 and T1ρrelaxation times of cartilage identifies differences between healthy and ACL-injured individuals at 3T", Osteoarthritis Cartilage, 25, pp.513~520 (2017)
  156. Blystad I, "Quantitative MRI for analysis of active multiple sclerosis lesions without gadoliniumbased contrast agent", AJNR Am J Neuroradiol, 37, pp.94~100 (2016)
  157. Neema M, "3 T MRI relaxometry detects T2 prolongation in the cerebral normal-appearing white matter in multiple sclerosis", Neuroimage, 46, pp.633~641 (2009)
  158. Mainero C, "A gradient in cortical pathology in multiple sclerosis by in vivo quantitative 7 T imaging", Brain, 138(Pt 4), pp.932~945 (2015)
  159. Gold GE, "Musculoskeletal MRI at 3. 0 T : relaxation times and image contrast", AJR Am J Roentgenol, 183, pp.343~351 (2004)
  160. Heye T, "MR relaxometry of the liver : significant elevation of T1 relaxation time in patients with liver cirrhosis", Eur Radiol, 22, pp.1224~1232 (2012)
  161. Obmann VC, "Liver MR relaxometry at 3T-segmental normal T1 and T2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness", Sci Rep, 9, pp.8106~ (2019)
  162. Jordan CD, "Musculoskeletal MRI at 3. 0 T and 7. 0 T : a comparison of relaxation times and image contrast", Eur J Radiol, 82, pp.734~739 (2013)
  163. Hanson CA, "T2relaxation times at cardiac MRI in healthy adults : a systematic review and meta-analysis", Radiology, 297, pp.344~351 (2020)
  164. Huelnhagen T, "Myocardial effective transverse relaxation time T2* is elevated in hypertrophic cardiomyopathy : a 7. 0 T magnetic resonance imaging study", Sci Rep, 8, pp.3974~ (2018)
  165. Peters AM, "T2* measurements in human brain at 1. 5, 3 and 7 T", Magn Reson Imaging, 25, pp.748~753 (2007)
  166. Wansapura JP, "NMR relaxation times in the human brain at 3. 0 tesla", J Magn Reson Imaging, 9, pp.531~538 (1999)
  167. Gelman N, "MR imaging of human brain at 3. 0 T : preliminary report on transverse relaxation rates and relation to estimated iron content", Radiology, 210, pp.759~767 (1999)
  168. Zhang JL, "Reproducibility of R2* &R2 measurements in human kidneys", Proceedings of the 19th International Society for Magnetic Resonance in Medicine, pp.2954~ (2011)
  169. Li X, "Measuring renal tissue relaxation times at 7 T", NMR Biomed, 28, pp.63~69 (2015)
  170. Bushberg JT, "The essential physics of medical imaging" (2011), Lippincott Williams & Wilkins
  171. Daoust A, "Transverse relaxation of cerebrospinal fluid depends on glucose concentration", Magn Reson Imaging, 44, pp.72~81 (2017)
  172. Barth M, "Proton NMR relaxation times of human blood samples at 1. 5 T and implications for functional MRI", Cell Mol Biol(Noisy-le-grand), 43, pp.783~791 (1997)
  173. van Leeuwen FHP, "Detecting low blood concentrations in joints using T1 and T2 mapping at 1. 5, 3, and 7 T : an in vitro study", Eur Radiol Exp, 5, pp.51~ (2021)
  174. Krishnamurthy LC, "Dependence of blood T(2)on oxygenation at 7 T : in vitro calibration and in vivo application", Magn Reson Med, 71, pp.2035~2042 (2014)
  175. Lin AL, "Blood longitudinal(T1)and transverse(T2)relaxation time constants at 11. 7 tesla", MAGMA, 25, pp.245~249 (2012)

관련 논문AI추천

이 간행물의 다른 논문 (4건)