PHMG (polyhexamethylene guanidine) 흡입독성참고치 산출을 통한 가습기살균제 노출등급 분류 및 특성
Classification and Characterization of Exposure Rating in Humidifier Disinfectants through Calculation of PHMG Reference Concentration
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objectives: The Korean Ministry of Environment has identified cases of people suspected of suffering lung disease potentially caused by polyhexamethylene guanidine (PHMG) used in humidifier disinfectants (HDs). Exposure assessment for the HDs was conducted using a questionnaire during face-to-face interview. The main purposes of this study were to develop a methodology to effectively classify levels of exposure to HDs based on a questionnaire. Methods: We first identified the overall participants’ exposure characteristics by HD exposure levels; Second, we selected misclassified subjects and investigated characteristics of overestimated and underestimated subjects, focusing on exposure cases to PHMG-containing HDs. An inhalation reference concentration (RfC) for PHMG was produced on the basis of inhalation toxicity values. We made a cross-tabulation of the exposure classes (Exposure classes 1-to-4) by clinical classes based on the RfC. When the value of the exposure class minus the clinical class was 0 or 1, we assumed these were true values. When the value was ≥2 and ≤ −2, we assigned these cases to the overestimation group and underestimation group, respectively. Results: The overestimated group may have already recovered and responded excessively due to psychological anxiety or in order to receive compensation. On the other hand, relatively high mortality rates and surrogate responses for those under 10 years of age may have resulted in inaccurate exposure assessment for underestimated groups. For the characteristics of exposure, it was shown that for the underestimated group, the exposure was relatively weaker than the overestimated group, even though a high overall clinical rating was determined. Conclusions: This study may suggest ways to reduce bias and overcome the limitations of current HD exposure assessment.
Abstract
Objectives: The Korean Ministry of Environment has identified cases of people suspected of suffering lung disease potentially caused by polyhexamethylene guanidine (PHMG) used in humidifier disinfectants (HDs). Exposure assessment for the HDs was conducted using a questionnaire during face-to-face interview. The main purposes of this study were to develop a methodology to effectively classify levels of exposure to HDs based on a questionnaire. Methods: We first identified the overall participants’ exposure characteristics by HD exposure levels; Second, we selected misclassified subjects and investigated characteristics of overestimated and underestimated subjects, focusing on exposure cases to PHMG-containing HDs. An inhalation reference concentration (RfC) for PHMG was produced on the basis of inhalation toxicity values. We made a cross-tabulation of the exposure classes (Exposure classes 1-to-4) by clinical classes based on the RfC. When the value of the exposure class minus the clinical class was 0 or 1, we assumed these were true values. When the value was ≥2 and ≤ −2, we assigned these cases to the overestimation group and underestimation group, respectively. Results: The overestimated group may have already recovered and responded excessively due to psychological anxiety or in order to receive compensation. On the other hand, relatively high mortality rates and surrogate responses for those under 10 years of age may have resulted in inaccurate exposure assessment for underestimated groups. For the characteristics of exposure, it was shown that for the underestimated group, the exposure was relatively weaker than the overestimated group, even though a high overall clinical rating was determined. Conclusions: This study may suggest ways to reduce bias and overcome the limitations of current HD exposure assessment.
참고문헌 (23)
- Mohan AK, "Humidifier use in the home environment and its effects on respiratory health", Journal of Occupational and Environmental Hygiene, 13, pp.782~787 (1998)
- 박순미, "중환자실 내 가습기의 소독방법과 시간적 경과에 따른 균집락 수", Journal of Korean Biological Nursing Science, 11(1), pp.92~98 (2009), 한국기초간호학회
- Daftary AS, "Inhalational lung injury associated with humidifier “white dust.”", Official Journal of the American Academy of Pediatrics, 127, pp.509~512 (2011)
- 박동욱, "가습기 살균제 제품에 표기된 안전보건정보 고찰", 한국환경보건학회지, 43(5), pp.349~359 (2017), 한국환경보건학회
- U.S. EPA, "Indoor air facts No. 8 use and care of home humidifiers", Office of Air and Radiation, Office of Research and Development, U.S. Environmental Protection Agency (402-F-91-101), ~ (1991)
- Ryu SH, "Humidifier disinfectant and use characteristics associated with ling injury in Korea", Indoor Air, 29, pp.735~747 (2019)
- 최윤형, "가습기살균제 피해 신청자들의 인구학적 특성 및 노출평가 - 4-1차와 4-2차 신청자를 중심으로 -", 한국환경보건학회지, 44(4), pp.301~314 (2018), 한국환경보건학회
- "Statistical data"[URL]
- Ryu HS, "Analysis of affecting factors of lung disease in the damaged applicants by usage of humidifier disinfectants, 2017-2019" (2019), Daegu Catholic University
- A safety study for management of the existing chemicals (I), "NIER", National Institute of Environmental Research, ~ (2013)
- Risk assessment guidance for superfund volume I: Human health evaluation manual part F, Supplemental guidance for inhalation risk assessment, "U.S. EPA", Office of Superfund Remediation and Technology Innovation, U.S. Environmental Protection Agency, ~, pp.540-R-070-002 (2009)
- ECHA, "Guidance on information requirements and chemical safety assessment", European Chemicals Agency, ~ (2012)
- KCDC, "Analytical results of the chemical components of various humidifier disinfectant brands from KCDC’s parliamentary inspection", Korea Center for Disease Control and Prevention, ~ (2011)
- Risk assessment of 3D Printers and 3D printed products, "U.S. EPA", U.S. Environmental Protection Agency, ~ (2017)
- 박진현, "시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정", 한국환경보건학회지, 45(1), pp.1~8 (2019), 한국환경보건학회[DOI]
- A strategy for assessing and managing occupational exposures third edition, "AIHA", American Industrial Hygiene Association, ~ (2006)
- 임철홍, "산업안전보건법 상 유해성・위험성 평가제도 적용을 위한 양-반응 평가의 통일화 방안 연구", 한국산업보건학회지, 22(3), pp.175~183 (2012), 한국산업보건학회[DOI]
- The recommendation for the management levels in occupational safety and health act(OSHA)and additional enactment of occupational exposure limits(OELs)chemicals, "Lee KS", Research Report of Occupational Safety and Health Research Institute, 1~6, pp.2015-OSHRI-1103 (2015)
- 이권섭, "HCFC-123의 급성 독성간질환 발생 사례에 따른 노출기준 및 법 관리 필요성 권고", 한국산업보건학회지, 28(1), pp.80~90 (2018), 한국산업보건학회[DOI]
- 박동욱, "가습기 살균제 건강 피해 조사에서 노출 평가 방법 고찰", 한국환경보건학회지, 44(2), pp.107~114 (2018), 한국환경보건학회
- Jang DD, "Guidance for human exposure assessment", National Institute of Toxicological Research, ~ (2007)
- Gorman BK, "Gender disparities in adult health : An examination of three measures of morbidity", Journal of Health Socical Behavior, 47, pp.95~110 (2006)
- Read JG, "Gender and health inequality", Annual Review of Sociology, 36, pp.371~386 (2010)
