가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석
Affecting Factors of Lung Disease and Classification of Exposure Rating of Applicants for Injuries from Humidifier Disinfectants
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background: Lung injuries due to exposure to humidifier disinfectants (HDs) were reported in 2011 in South Korea. As a result of the government’s epidemiological investigation and toxicity test study, it was found that HDs caused health damage such as lung disease. Objectives: The purpose of this study was to classify HD exposure ratings and analyze the affecting factors that could identify the relationship with lung disease. Methods: Exposure assessment for HDs was conducted using a questionnaire during face-to-face interviews with the applicants. Ratings of high exposure (Class 1) and low exposure (Class 2) were cross-tabulated with clinical ratings (acceptable and unacceptable). Logistic regression analysis was carried out by setting the clinical rating of lung disease as a dependent variable and the socio-demographic and exposure characteristics obtained through the questionnaire as independent variables. Results: The concentration in air of polyhexamethylene guanidine (PHMG) was 71.96±107.47 µg/m3, and the exposure concentration was 15.21±23.28 µg/m3. The exposure rating was overestimated with 97.1% of affected subjects having high exposure using margin of exposure (MOE), but only 9.9% matching the clinical class. In the overestimated group, it could be explained by the fact that the exposure time was long and the subjects had already recovered from damage symptoms. As a result of logistic regression analysis, ten variables were found to be significant inf luencing factors. Conclusions: A new exposure rating could be calculated based on the MOE, and factors affecting lung disease could be estimated through comparative evaluation with the clinical rating.
Abstract
Background: Lung injuries due to exposure to humidifier disinfectants (HDs) were reported in 2011 in South Korea. As a result of the government’s epidemiological investigation and toxicity test study, it was found that HDs caused health damage such as lung disease. Objectives: The purpose of this study was to classify HD exposure ratings and analyze the affecting factors that could identify the relationship with lung disease. Methods: Exposure assessment for HDs was conducted using a questionnaire during face-to-face interviews with the applicants. Ratings of high exposure (Class 1) and low exposure (Class 2) were cross-tabulated with clinical ratings (acceptable and unacceptable). Logistic regression analysis was carried out by setting the clinical rating of lung disease as a dependent variable and the socio-demographic and exposure characteristics obtained through the questionnaire as independent variables. Results: The concentration in air of polyhexamethylene guanidine (PHMG) was 71.96±107.47 µg/m3, and the exposure concentration was 15.21±23.28 µg/m3. The exposure rating was overestimated with 97.1% of affected subjects having high exposure using margin of exposure (MOE), but only 9.9% matching the clinical class. In the overestimated group, it could be explained by the fact that the exposure time was long and the subjects had already recovered from damage symptoms. As a result of logistic regression analysis, ten variables were found to be significant inf luencing factors. Conclusions: A new exposure rating could be calculated based on the MOE, and factors affecting lung disease could be estimated through comparative evaluation with the clinical rating.
참고문헌 (33)
- 김은채, "PHMG (polyhexamethylene guanidine) 흡입독성참고치 산출을 통한 가습기살균제 노출등급 분류 및 특성", 한국환경보건학회지, 46(3), pp.335~343 (2020), 한국환경보건학회[DOI]
- Quinn A, "Indoor temperature and humidity in New York City apartments during winter", Sci Total Environ, 583, pp.29~35 (2017)
- Yoon C, "Assessment of hazardous substances concentration in the air according to the type of water used in the humidifier", Korean J Public Health, 56(1), pp.33~39 (2019)
- Ryu H, "Misclassification and characterization of exposure to humidifier disinfectants using a questionnaire", BMC Public Health, 21(1), pp.1458~ (2021)
- Daftary AS, "Inhalational lung injury associated with humidifier"white dust"", Pediatrics, 127(2), pp.e509~e512 (2011)
- 이혜림, "PHMG-Phosphate의 직업적 유해성평가를 통한 노출기준 제안 연구", 한국산업보건학회지, 29(1), pp.13~20 (2019), 한국산업보건학회[DOI]
- Korea Centers for Disease Control and Prevention (KCDC), "Analytical Results of the Chemical Components of Various Humidifier Disinfectant Brands from KCDC’s Parliamentary Inspection" (2011), KCDC
- Korean Society of Environmental Health(KSEH), "Case Studies on Victims of Humidifier Disinfectants" (2012), Korean Society of Environmental Health
- 김지원, "염화벤잘코늄(Benzalkonium chloride) 살균제의 용도 및 건강 위험에 대한 고찰 -가습기 살균제를 중심으로", 한국환경보건학회지, 47(6), pp.513~520 (2021), 한국환경보건학회[DOI]
- Ryu SH, "Humidifier disinfectant and use characteristics associated with lung injury in Korea", Indoor Air, 29(5), pp.735~747 (2019)
- National Institute of Environmental Research(NIER), "Establishing Disease Identification and Standards Criteria to Expand the Range of Health Hazards Caused by the Humidifier Sterilizer" (2017), National Institute of Environmental Research
- Ministry of Environment(MoE), "2017 White Paper of Environment" (2017), Ministry of Environment
- "Statistical Data"[URL]
- 최윤형, "가습기살균제 피해 신청자들의 인구학적 특성 및 노출평가 - 4-1차와 4-2차 신청자를 중심으로 -", 한국환경보건학회지, 44(4), pp.301~314 (2018), 한국환경보건학회
- Kim EC, "nalysis of affecting factors of lung disease according to exposure and socio-demographic characteristics in the affected victims by usage of humidifier disinfectants", pp.2021
- Nieuwenhuijsen MJ, "Exposure assessment in occupational and environmental epidemiology" (2003), Oxford University Press
- Kim S, "Assessment of factors affecting the exposure on local community", pp.2014
- Manini P, "Exposure assessment at the workplace:implications of biological variability", Toxicol Lett, 168(3), pp.210~218 (2007)
- National Institute of Environmental Research(NIER), "A Safety Study for Management of the Existing Chemicals(I)" (2013), National Institute of Environmental Research
- "Chemical Information"[URL]
- 박진현, "시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정", 한국환경보건학회지, 45(1), pp.1~8 (2019), 한국환경보건학회[DOI]
- Yang W, "Characterization of indoor air quality using multiple measurements of nitrogen dioxide", Indoor Air, 14(2), pp.105~111 (2004)
- Diapouli E, "Estimating the concentration of indoor particles of outdoor origin : a review", J Air Waste Manag Assoc, 63(10), pp.1113~1129 (2013)
- Yao W, "Human exposure to particles at the air-water interface : influence of water quality on indoor air quality from use of ultrasonic humidifiers", Environ Int, 143, pp.105902~ (2020)
- United States Environmental Protection Agency (U.S. EPA), "Risk Assessment Guidance for Superfund Volume I: Human Health Evaluation Manual (Part F, Supplemental Guidance for Inhalation Risk Assessment)" (2009), EPA
- Shim HE, "Quantification of inhaled aerosol particles composed of toxic household disinfectant using radioanalytical method", Chemosphere, 207, pp.649~654 (2018)
- Delgado-Rodríguez M, "Bias", J Epidemiol Community Health, 58(8), pp.635~641 (2004)
- Paek D, "Nationwide study of humidifier disinfectant lung injury in South Korea, 1994-2011. Incidence and dose-response relationships", Ann Am Thorac Soc, 12(12), pp.1813~1821 (2015)
- 박광식, "An analysis of a humidifier disinfectant case from a toxicological perspective", 환경독성보건학회지, 31, pp.1~4 (2016), 환경독성보건학회
- 박동욱, "가습기 살균제 피해자 호흡기로 흡입된 가습기 살균제 양 추정 - 호흡기 외부(external) 및 내부 노출(internal exposure) 추정 방법과 사례 -", 한국환경보건학회지, 42(3), pp.141~146 (2016), 한국환경보건학회
- Vahtera J, "Sex differences in health effects of family death or illness: are women more vulnerable than men?", Psychosom Med, 68(2), pp.283~291 (2006)
- Read JG, "Gender and health inequality", Annu Rev Sociol, 36, pp.371~386 (2010)
- 최예용, "가습기살균제 피해사건과 교훈", 한국환경보건학회지, 38(02), pp.166~174 (2012), 한국환경보건학회[DOI]
