최적의 FOV를 위한 MR신호강도와 신호 대 잡음비 값의 비교분석

Analysis and Comparison of MR Signal Strength and SNR Value for Optimal FOV

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Despite the continuous development of software, it is continuously pursued to enlarge the examination area of FOV in order to reduce the factors of inconsistency in images that appear in continuous examination during wide area examination using contrast agent such as whole body angiography. In this study, we investigated the optimal FOV by comparing the SNR values according to the changes of FOV. The change of the FOV was gradually changed to 270 × 200, 300 × 223, 330 × 244, 360 × 266 and 380 × 281. SE images at TR 450 msec and TE 10 msec, FSE images at TR 2,000 msec, TE 80msec, and GE images were scanned at TR 117 msec, and TE 16msec. SNR values were calculated from the mean values of signal intensities of five phantom images and the signal intensity values of four background standard deviations. As a result of the study, the signal intensity and the SNR value according to the change of the FOV value gradually increased as the FOV was increased, but it was found that the SNR value decreased at a constant size. In conclusion, the results are different from previous studies that the SNR increases as the FOV increases. The cause of these results could not be confirmed. However methods that can be imaged and included within the effective FOV should be considered.

Abstract

Despite the continuous development of software, it is continuously pursued to enlarge the examination area of FOV in order to reduce the factors of inconsistency in images that appear in continuous examination during wide area examination using contrast agent such as whole body angiography. In this study, we investigated the optimal FOV by comparing the SNR values according to the changes of FOV. The change of the FOV was gradually changed to 270 × 200, 300 × 223, 330 × 244, 360 × 266 and 380 × 281. SE images at TR 450 msec and TE 10 msec, FSE images at TR 2,000 msec, TE 80msec, and GE images were scanned at TR 117 msec, and TE 16msec. SNR values were calculated from the mean values of signal intensities of five phantom images and the signal intensity values of four background standard deviations. As a result of the study, the signal intensity and the SNR value according to the change of the FOV value gradually increased as the FOV was increased, but it was found that the SNR value decreased at a constant size. In conclusion, the results are different from previous studies that the SNR increases as the FOV increases. The cause of these results could not be confirmed. However methods that can be imaged and included within the effective FOV should be considered.

참고문헌 (12)

  1. HY Carr, "Steady-state free precession in nuclear magnetic resonance", The American Physical Society, Physical Review, 112(5), pp.1693~1701 (1958)
  2. KP Pruessmann, "SENSE: sensitivity encoding for fast MRI", Magnetic resonance in medicine;, 42(5), pp.952~962 (1999)[DOI]
  3. K Setsompop, "Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty", Magnetic Resonance in Medicine, 67(5), pp.1210~1224 (2012)[DOI]
  4. 한재복, "FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle", 방사선기술과학, 32(1), pp.101~106 (2009), 대한방사선과학회
  5. C Zhu, "Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus", Magnetic Resonance Imaging, 34(1), pp.18~25 (2016)[DOI]
  6. Schmidt GP, "Whole-body imaging of the musculoskeletal system: the value of MR imaging", Skeletal Radiology, 36(12), pp.1109~1119 (2007)[DOI]
  7. Christian Wachinger, "Deformable Mosaicing for Whole-body MRI", Medical Image Computing and Computer-Assisted Intervention, 11(2), pp.113~121 (2008)
  8. C. Westbrook, "MRI in Practice" (2011), Wiley-Blackwell
  9. Callaghan PT, "Principles of nuclear magnetic resonance microscopy" (1991), Clarendon Press
  10. Panych LP, "On replacing the manual measurement of ACR phantom images performed by MRI technologists with an automated measurement approach", Journal of Magnetic Resonance Imaging, 43(4), pp.843~852 (2016)[DOI]
  11. 이재승, "1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구", 의학물리, 20(4), pp.245~253 (2009), 한국의학물리학회
  12. DavidG. Kruger, "Rossma :Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole body MRI", Magnetic Resonance in Medicine, 47(2), pp.224~231 (2002)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (10건)