본문 바로가기
KERD
논문KCI 등재

Influence of camera position, implant angulation and implant reference on the accuracy of complete arch implant recordings with photogrammetry

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. The aim of the present study was to assess the influence of various implant angulations, camera positions and number of implant references on the accuracy of a photogrammetry device for complete arch implant prostheses. Materials and methods. 2 edentulous models, one with 6 parallel implants (PM) and other with 6 angled implants (AM), underwent digitalization with a coordinate measuring machine (CMM) to establish a reference standard. Both models underwent 20 impressions with 2 different camera positions and 3 different implant references, with a total of 240 impressions. Euclidean linear and angular measurements were obtained on the reference cast and each experimental scan and compared. Absolute (n) and relative frequencies (%) of true and precise measurements at 95% confidence intervals (CI) were calculated. Chi-squared tests were used to assess differences in trueness and precision between these factors. Results. 3660 distances and 1440 angles were analyzed for trueness. The absolute difference was 54 ± 46 µm and 0.341 ± 0.301º. Precision was 18 ± 23 µm from 68400 measured distances and 0.048 ± 0.074º for the 22800 angulations measured. Statistically significant differences (P < .05) were identified between PM and Am, A1 and A2 and number of references in both distances and angulations for trueness and precision. Conclusion. Implant angulations, camera positions and number of implant references used affected the precision and trueness of Precise Implant Capture (PIC) system. However, these differences did not show clinically relevant values.

Abstract

Purpose. The aim of the present study was to assess the influence of various implant angulations, camera positions and number of implant references on the accuracy of a photogrammetry device for complete arch implant prostheses. Materials and methods. 2 edentulous models, one with 6 parallel implants (PM) and other with 6 angled implants (AM), underwent digitalization with a coordinate measuring machine (CMM) to establish a reference standard. Both models underwent 20 impressions with 2 different camera positions and 3 different implant references, with a total of 240 impressions. Euclidean linear and angular measurements were obtained on the reference cast and each experimental scan and compared. Absolute (n) and relative frequencies (%) of true and precise measurements at 95% confidence intervals (CI) were calculated. Chi-squared tests were used to assess differences in trueness and precision between these factors. Results. 3660 distances and 1440 angles were analyzed for trueness. The absolute difference was 54 ± 46 µm and 0.341 ± 0.301º. Precision was 18 ± 23 µm from 68400 measured distances and 0.048 ± 0.074º for the 22800 angulations measured. Statistically significant differences (P < .05) were identified between PM and Am, A1 and A2 and number of references in both distances and angulations for trueness and precision. Conclusion. Implant angulations, camera positions and number of implant references used affected the precision and trueness of Precise Implant Capture (PIC) system. However, these differences did not show clinically relevant values.

관련 논문AI추천

Effect of reference objects on the accuracy of digital implant impressions in partially edentulous archesAgnė Gedrimienė, Darius Jegelevičius, Justinas Pletkus, Liudas Auškalnis, Mutlu Özcan, Mykolas Akulauskas, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제5호Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressionsFunda Bayindir, Ismail Hakki Korkmaz, Ozcan Akkal대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제4호Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorationsDilem Toksoy, Oguz Ozan, Özay Önöral, Sevcan Kurtulmus-Yilmaz대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제6호Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro studyChuchai Anunmana, Prakan Thanasrisuebwong, Tharathip Kulchotirat대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Effect of the scan body alignment process on the accuracy of virtual definitive implant casts: a pilot studyAna Suárez, Andrea Santamaría Laorden, Cristina Andreu Vázquez, Jaime Orejas Pérez대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제5호Reverse engineering technique on the evaluation of impression accuracy in angulated implants박진홍, 송소연, 이기선, 이정열, 정홍택대한치과보철학회 · 대한치과보철학회지2021 · 제59권 제3호

이 간행물의 다른 논문 (6건)