본문 바로가기
KERD
논문KCI 등재

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

2

조회

0

다운로드

6

인용

0

참고문헌

키워드

초록

PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by 10°–20° and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal–Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann–Whitney U test with Bonferroni correction (α=.05). RESULTS. Precision discrepancies for the canine, premolar, and molar were 3.7 μm, 3.2 μm, and 7.3 μm, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were 6.2 μm, 11.2 μm, and 21.8 μm, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

Abstract

PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by 10°–20° and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal–Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann–Whitney U test with Bonferroni correction (α=.05). RESULTS. Precision discrepancies for the canine, premolar, and molar were 3.7 μm, 3.2 μm, and 7.3 μm, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were 6.2 μm, 11.2 μm, and 21.8 μm, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

참고문헌 (27)

  1. Naidu D., "Validity, reliability, and reproducibility of the iOC intraoral scanner : a comparison of tooth widths and Bolton ratios", Am J Orthod Dentofacial Orthop, 144, pp.304~310 (2013)
  2. Flügge TV., "Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner", Am J Orthod Dentofacial Orthop, 144, pp.471~478 (2013)
  3. Persson AS., "Digitization of simulated clinical dental impressions : virtual three-dimensional analysis of exactness", Dent Mater, 25, pp.929~936 (2009)
  4. Quaas S., "Direct mechanical data acquisition of dental impressions for the manufacturing of CAD", CAM restorations, 2007, pp.35, 903~908
  5. Persson A., "A three-dimensional evaluation of a laser scanner and a touchprobe scanner", J Prosthet Dent, 95, pp.194~200 (2006)
  6. Persson AS., "Digitization of simulated clinical dental impressions : virtual three-dimensional analysis of exactness", Dent Mater, 25, pp.929~936 (2009)
  7. Schaefer O., "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro : a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)
  8. Chang M., "Automated scanning of dental impressions", Comput-aided des, 41, pp.404~411 (2009)
  9. Brosky ME., "Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy", J Prosthet Dent, 87, pp.204~209 (2002)
  10. Khardekar R., "Finding feasible mold parting directions using graphics hardware", Comput-aided des, 38, pp.327~341 (2006)
  11. Priyadarshi AK., "Geometric algorithms for automated design of multi-piece permanent molds", Computaided des, 36, pp.241~260 (2004)
  12. "ISO 5725-1:2003. Accuracy (trueness and precision) of measurement methods and results? Part 1: General principles and definitions", ISO, ~ (2003)
  13. Hoyos A., "Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions", Int J Prosthodont, 24, pp.49~54 (2011)
  14. Ziegler M., "Digital impression taking with reproducibly high precision", Int J Comput Dent, 12, pp.159~163 (2009)
  15. Chandran DT., "Twoand three-dimensional accuracy of dental impression materials : effects of storage time and moisture contamination", Biomed Mater Eng, 20, pp.243~249 (2010)
  16. Wöstmann B., "Accuracy of impressions obtained with dual-arch trays", Int J Prosthodont, 22, pp.158~160 (2009)
  17. Alikhasi M., "A comparison of precision of fit, rotational freedom, and torque loss with copy-milled zirconia and prefabricated titanium abutments", Int J Oral Maxillofac Implants, 28, pp.996~1002 (2013)
  18. Webber B., "An in vitro study of the compressive load at fracture of Procera AllCeram crowns with varying thickness of veneer porcelain", J Prosthet Dent, 89, pp.154~160 (2003)
  19. Quaas S., "Direct mechanical data acquisition of dental impressions for the manufacturing of CAD", CAM restorations, 2007, pp.35, 903~908
  20. Luthardt RG., "Accuracy of intraoral data acquisition in comparison to the conventional impression", Int J Comput Dent, 8, pp.283~294 (2005)
  21. Kenyon BJ., "Dimensional accuracy of 7 die materials", J Prosthodont, 14, pp.25~31 (2005)
  22. DeLong R., "Accuracy of a system for creating 3D computer models of dental arches", J Dent Res, 82, pp.438~442 (2003)
  23. Rudolph H., "Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD", CAM technology, 2007, pp.37, 579~587
  24. 전진훈, "White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions", The Journal of Advanced of Prosthodontics, 5(4), pp.452~456 (2013), 대한치과보철학회[DOI]
  25. Persson M., "The accuracy of a high-precision digitizer for CAD", CAM of crowns, 1995, pp.74, 223~229
  26. Moldovan O., "Threedimensional fit of CAD", CAM-made zirconia copings, 2011, pp.27, 1273~1278
  27. Persson AS., "Computer aided analysis of digitized dental stone replicas by dental CAD", CAM technology, 2008, pp.24, 1123~1130

관련 논문AI추천

이 간행물의 다른 논문 (17건)