Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The B0 maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled B0 map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MRvisible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

Abstract

Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The B0 maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled B0 map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MRvisible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

참고문헌 (12)

  1. Schenck JF, "The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds", Med Phys, 23, pp.815~850 (1996)[DOI]
  2. Schwartz B, "Superconductor applications: SQUIDs and machines" (2013), Springer US
  3. "MPMS 3 Product Description"[URL]
  4. Wapler MC, "Magnetic properties of materials for MR engineering, micro-MR and beyond", J Magn Reson, 242, pp.233~242 (2014)[DOI]
  5. Neelavalli J, "A fast and robust method for quantifying magnetic susceptibility of arbitrarily shaped objects using MR", Proc Intl Soc Mag Reson Med, 16, pp.3056~ (2008)
  6. Yoder DA, "MRI simulator with object-specific field map calculations", Magn Reson Imaging, 22, pp.315~328 (2004)[DOI]
  7. Lee SK, "Rapid, theoretically artifact-free calculation of static magnetic field induced by voxelated susceptibility distribution in an arbitrary volume of interest", Magn Reson Med, 80, pp.2109~2121 (2018)[DOI]
  8. Chu SC, "Bulk magnetic susceptibility shifts in NMR studies of compartmentalized samples: use of paramagnetic reagents", Magn Reson Med, 13, pp.239~262 (1990)[DOI]
  9. 조은혜, "Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging", Investigative Magnetic Resonance Imaging, 15(1), pp.11~21 (2011), 대한자기공명의과학회
  10. Czervionke LF, "Magnetic susceptibility artifacts in gradient-recalled echo MR imaging", AJNR Am J Neuroradiol, 9, pp.1149~1155 (1988)
  11. Astary GW, "MR measurement of alloy magnetic susceptibility: towards developing tissue- susceptibility matched metals", J Magn Reson, 233, pp.49~55 (2013)[DOI]
  12. 박소희, "Quantification of Gadolinium Concentration Using GRE and UTE Sequences", Investigative Magnetic Resonance Imaging, 21(3), pp.171~176 (2017), 대한자기공명의과학회[DOI]