Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: To generate phase images with free of motion-induced artifact and susceptibility-induced distortion using 3D radial ultrashort TE (UTE) MRI. Materials and Methods: The field map was theoretically derived by solving Laplace’s equation with appropriate boundary conditions, and used to simulate the image distortion in conventional spin-warp MRI. Manufacturer’s 3D radial imaging sequence was modified to acquire maximum number of radial spokes in a given time, by removing the spoiler gradient and sampling during both rampup and rampdown gradient. Spoke direction randomly jumps so that a readout gradient acts as a spoiling gradient for the previous spoke. The custom raw data was reconstructed using a homemade image reconstruction software, which is programmed using Python language. The method was applied to a phantom and in-vivo human brain and abdomen. The performance of UTE was compared with 3D GRE for phase mapping. Local phase mapping was compared with T2* mapping using UTE. Results: The phase map using UTE mimics true field-map, which was theoretically calculated, while that using 3D GRE revealed both motion-induced artifact and geometric distortion. Motion-free imaging is particularly crucial for application of phase mapping for abdomen MRI, which typically requires multiple breathold acquisitions. The air pockets, which are caught within the digestive pathway, induce spatially varying and large background field. T2* map, that was calculated using UTE data, suffers from non-uniform T2* value due to this background field, while does not appear in the local phase map of UTE data. Conclusion: Phase map generated using UTE mimicked the true field map even when non-zero susceptibility objects were present. Phase map generated by 3D GRE did not accurately mimic the true field map when non-zero susceptibility objects were present due to the significant field distortion as theoretically calculated. Nonetheless, UTE allows for phase maps to be free of susceptibility-induced distortion without the use of any post-processing protocols.

Abstract

Purpose: To generate phase images with free of motion-induced artifact and susceptibility-induced distortion using 3D radial ultrashort TE (UTE) MRI. Materials and Methods: The field map was theoretically derived by solving Laplace’s equation with appropriate boundary conditions, and used to simulate the image distortion in conventional spin-warp MRI. Manufacturer’s 3D radial imaging sequence was modified to acquire maximum number of radial spokes in a given time, by removing the spoiler gradient and sampling during both rampup and rampdown gradient. Spoke direction randomly jumps so that a readout gradient acts as a spoiling gradient for the previous spoke. The custom raw data was reconstructed using a homemade image reconstruction software, which is programmed using Python language. The method was applied to a phantom and in-vivo human brain and abdomen. The performance of UTE was compared with 3D GRE for phase mapping. Local phase mapping was compared with T2* mapping using UTE. Results: The phase map using UTE mimics true field-map, which was theoretically calculated, while that using 3D GRE revealed both motion-induced artifact and geometric distortion. Motion-free imaging is particularly crucial for application of phase mapping for abdomen MRI, which typically requires multiple breathold acquisitions. The air pockets, which are caught within the digestive pathway, induce spatially varying and large background field. T2* map, that was calculated using UTE data, suffers from non-uniform T2* value due to this background field, while does not appear in the local phase map of UTE data. Conclusion: Phase map generated using UTE mimicked the true field map even when non-zero susceptibility objects were present. Phase map generated by 3D GRE did not accurately mimic the true field map when non-zero susceptibility objects were present due to the significant field distortion as theoretically calculated. Nonetheless, UTE allows for phase maps to be free of susceptibility-induced distortion without the use of any post-processing protocols.

참고문헌 (37)

  1. Haacke EM, "Susceptibility-weighted imaging: technical aspects and clinical applications, part 1", AJNR Am J Neuroradiol, 30, pp.19~30 (2009)
  2. Mittal S, "Susceptibilityweighted imaging: technical aspects and clinical applications, part 2", AJNR Am J Neuroradiol, 30, pp.232~252 (2009)
  3. Shmueli K, "Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data", Magn Reson Med, 62, pp.1510~1522 (2009)
  4. Schweser F, "Toward online reconstruction of quantitative susceptibility maps: superfast dipole inversion", Magn Reson Med, 69, pp.1582~1594 (2013)
  5. Haacke EM, "Magnetic resonance imaging, physical principles and sequence design" (1999), Wiley-Liss
  6. Zhou XJ, "Handbook of MRI pulse sequences" (2005), Elsevier Science
  7. Slichter CP, "Principles of magnetic resonance" (1990), Springer-Verlag
  8. Fukushima E, "Experimental pulse NMR: A nuts and bolts approach" (1981), Addison-Wesley Publishing Company, Inc
  9. Sharma SD, "Quantitative susceptibility mapping in the abdomen as an imaging biomarker of hepatic iron overload", Magn Reson Med, 74, pp.673~683 (2015)
  10. Barrera Portillo MC, "Liver and heart T2* measurement in secondary haemochromatosis", Radiologia, 55, pp.331~339 (2013)
  11. Li W, "Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition", Neuroimage, 55, pp.1645~1656 (2011)
  12. He X, "Biophysical mechanisms of phase contrast in gradient echo MRI", Proc Natl Acad Sci U S A, 106, pp.13558~13563 (2009)
  13. Yablonskiy DA, "Biophysical mechanisms of MRI signal frequency contrast in multiple sclerosis", Proc Natl Acad Sci U S A, 109, pp.14212~14217 (2012)
  14. Jeong EK, "Highresolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI)", Magn Reson Med, 54, pp.1575~1579 (2005)
  15. He Q, "Direct magnitude and phase imaging of myelin using ultrashort echo time (UTE) pulse sequences: a feasibility study", Magn Reson Imaging, 39, pp.194~199 (2017)
  16. Xie L, "Dynamic contrast-enhanced quantitative susceptibility mapping with ultrashort echo time MRI for evaluating renal function", Am J Physiol Renal Physiol, 310, pp.F174~F182 (2016)
  17. Gho SM, "Simultaneous quantitative mapping of conductivity and susceptibility using a double-echo ultrashort echo time sequence:Example using a hematoma evolution study", Magn Reson Med, 76, pp.214~221 (2016)
  18. Jackson JD, "Classical electrodynamics" (1975), Wiley
  19. Griffiths DJ, "Introduction to electrodynamics" (2012), Pearson
  20. Case TA, "A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: calculations and measurements", J Magn Reson, 73, pp.304~314 (1987)
  21. Salomir R, "A fast calculation method for magnetic field inhomogeneity due to an arbitrary distribution of bulk susceptibility", Concepts Magn Reson Part B Magn Reson Eng, 19, pp.26~34 (2003)
  22. Abdul-Rahman HS, "Fast and robust three-dimensional best path phase unwrapping algorithm", Appl Opt, 46, pp.6623~6635 (2007)
  23. Robinson S, "Combining phase images from multi-channel RF coils using 3D phase offset maps derived from a dual-echo scan", Magn Reson Med, 65, pp.1638~1648 (2011)
  24. van der Walt S, "The NumPy array:a structure for efficient numerical computation", Comput Sci Eng, 13, pp.22~30 (2011)
  25. Oliphant TE, "SciPy: Open source scientific tools for Python", Comput Sci Eng, 9, pp.10~20 (2007)
  26. Hunter JD, "Matplotlib: A 2D graphics environment", Comput Sci Eng, 9, pp.99~104 (2007)
  27. Hunter JD., "Matplotlib: A 2D graphic environment", Comput Sci Eng, 9, pp.90~95 (2007)
  28. Nielles-Vallespin S, "3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle", Magn Reson Med, 57, pp.74~81 (2007)
  29. Jackson JI, "Selection of a convolution function for Fourier inversion using gridding", IEEE Trans Med Imaging, 10, pp.473~478 (1991)
  30. Johnson KO, "Convolution kernel design and efficient algorithm for sampling density correction", Magn Reson Med, 61, pp.439~447 (2009)
  31. Liu C, "Susceptibilityweighted imaging and quantitative susceptibility mapping in the brain", J Magn Reson Imaging, 42, pp.23~41 (2015)
  32. Schweser F, "Quantitative imaging of intrinsic magnetic tissue properties using MRI signal phase: an approach to in vivo brain iron metabolism?", Neuroimage, 54, pp.2789~2807 (2011)
  33. Schenck JF, "The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds", Med Phys, 23, pp.815~850 (1996)
  34. Yu H, "Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation", J Magn Reson Imaging, 26, pp.1153~1161 (2007)
  35. Yu H, "Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling", Magn Reson Med, 60, pp.1122~1134 (2008)
  36. Speier P, "A calibration for radial imaging with large inplane shifts", Proceedings of the 13th Annual Meeting of ISMRM, pp.2295~ (2005)
  37. Speier P, "Robust radial imaging with predetermined isotropic gradient delay correction", Proceedings of the 14th Annual Meeting of ISMRM, pp.2379~ (2006)

관련 논문AI추천

Background Gradient Correction using Excitation Pulse Profile for Fat and T2* Quantification in 2D Multi-Slice Liver Imaging김동현, 김한성, 남윤호, 조상영대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2012 · 제16권 제1호Simultaneous Unwrapping Phase and Error Recovery from Inhomogeneity (SUPER) for Quantitative Susceptibility Mapping of the Human Brain백현만, 안창범, 양영중, Jong-Hyun Yoon대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2018 · 제22권 제1호Partial Solution for Concomitant Gradient Field in Ultra-low Magnetic Field: Correction of Distortion Artifact심정현, 이성주한국자기공명학회 · Journal of the Korean Magnetic Resonance Society2020 · 제24권 제3호Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)Danny J.J. Wang, Kyunghyun Sung, Peng Hu, Shams Rashid, Steen Moeller, Thomas Martin, Xingfeng Shao, Yi Wang대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제4호Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature SurveySoham S. More, Xiaoliang Zhang대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2024 · 제28권 제4호Quantification of Gadolinium Concentration Using GRE and UTE Sequences남윤호, 박소희, 우승태, 최현석대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제3호

이 간행물의 다른 논문 (12건)