Determining the Location of Metallic Needle from MR Images Distorted by Susceptibility Difference

1

조회

0

다운로드

0

인용

0

참고문헌

주제분류방사선과학

초록

Purpose : To calculate the appearance of the image distortion from metallic artifacts and to determine the location of a metallic needle from a distorted MR image. Materials and Methods : To examine metal artifacts, an infinite metal cylinder in a strong magnetic field are assumed. The cylinder’s axis leaned toward the magnetic field along some arbitrary angle. The Laplace equation for this situation was solved to investigate the magnetic field distortion, and the simulation was performed to evaluation the image artifact caused by both readout and slice-selection gradient field. Using the result of the calculation, the exact locations of the metal cylinder were calculated from acquired images. Results : The distances between the center and the folded point are measured from images and calculated. Percentage errors between the measured and calculated distance were less than 5%, except for one case. Conclusion : The simulation was successfully performed when the metal cylinder was skewed at an arbitrary tilted angle relative to the main magnetic field. This method will make it possible to monitor and guide both biopsy and surgery with real time MRI.

Abstract

Purpose : To calculate the appearance of the image distortion from metallic artifacts and to determine the location of a metallic needle from a distorted MR image. Materials and Methods : To examine metal artifacts, an infinite metal cylinder in a strong magnetic field are assumed. The cylinder’s axis leaned toward the magnetic field along some arbitrary angle. The Laplace equation for this situation was solved to investigate the magnetic field distortion, and the simulation was performed to evaluation the image artifact caused by both readout and slice-selection gradient field. Using the result of the calculation, the exact locations of the metal cylinder were calculated from acquired images. Results : The distances between the center and the folded point are measured from images and calculated. Percentage errors between the measured and calculated distance were less than 5%, except for one case. Conclusion : The simulation was successfully performed when the metal cylinder was skewed at an arbitrary tilted angle relative to the main magnetic field. This method will make it possible to monitor and guide both biopsy and surgery with real time MRI.

참고문헌 (11)

  1. Lu ¨deke KM, "Susceptibility artefacts in NMR imaging", Magn Reson Imaging, 3, pp.329~343 (1985)
  2. Schenck JF, "The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds", Med Phys, 23, pp.815~850 (1996)
  3. Butts K, "Management of biopsy needle artifacts: techniques for RFrefocused MRI", J Magn Reson Imaging, 9, pp.586~595 (1999)
  4. Cho ZH, "Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting", Med Phys, 15, pp.7~11 (1988)
  5. Lu W, "SEMAC: Slice Encoding for Metal Artifact Correction in MRI", Magn Reson Med, 62, pp.66~76 (2009)
  6. Arbogast-Ravier S, "An in Vitro Study at Low Field for MR Guidance of a Biopsy Needle", Magn Reson Imaging, 13, pp.321~324 (1995)
  7. Ladd ME, "Biopsy needle susceptibility artifacts", Magn Reson Med, 36, pp.646~651 (1996)
  8. Lufkin R, "New Needle for MR-Guided Aspiration Cytology of the Head and Neck", AJR Am J Roentgenol, 149, pp.380~382 (1987)
  9. Lufkin R, "A Technique for MRGuided Needle Placement", AJR Am J Roentgenol, 151, pp.193~196 (1988)
  10. Liu H, "Interventional MRI at High- Field (1.5 T): Needle Artifacts", J Magn Reson Imaging, 8, pp.214~219 (1998)
  11. Balac S, "Integral method for Numerical Simulation of MRI Artifact Induced by Metallic Implants", Magn Reson Med, 45, pp.724~727 (2001)

관련 논문AI추천

이 간행물의 다른 논문 (9건)