Background and Objectives The aim of this study was to evaluate the usefulness of speechmapping based on real ear measurement for routine hearing aid fitting and to compare functionalgains for evaluating subjective satisfaction of hearing aid users. Subjects and Method Twenty two participants with bilateral symmetric (<10 dB HL difference)sensorineural hearing loss were enrolled in this study. All participants were fitted unilateralhearing aids with speech mapping using the National Acoustic Laboratories-Nonlinear 2formula. After the initial fitting, patients were followed with the 2nd and 3rd fitting at twoweeks and six weeks, respectively, and measured for aided pure tone average (PTA), aidedspeech discrimination score (SDS), the difference between target gain and real ear insertiongain (REIG) using speech mapping and subjective satisfaction via Korean Adaptation of theInternational Outcome Inventory for Hearing Aids (K-IOI-HA) questionnaire before furtherfitting was performed. We analyzed correlation of each parameter at 2nd and 3rd fitting withthe K-IOI-HA score. Results Every sequential aided PTA and SDS at 2nd fitting and 3rd fitting were significantlyimproved after repeated hearing aid fitting (all p<0.01). In the correlation analysis betweenK-IOI-HA and each parameter, the aided PTA and aided SDS did not show significant correlationswith subjective satisfaction from the 2nd and 3rd fittings. But the difference between thetarget gain and R EIG in speech mapping showed significant negative correlations with thesatisfaction scores at various speech level (r=-0.609 to -0.709, all p<0.01). Conclusion Speech mapping using real ear measurement was useful to expect subjectivesatisfaction of hearing aid users and it would be a valuable tool for fine tuning to achieve individualpreferences.

Abstract

Background and Objectives The aim of this study was to evaluate the usefulness of speechmapping based on real ear measurement for routine hearing aid fitting and to compare functionalgains for evaluating subjective satisfaction of hearing aid users. Subjects and Method Twenty two participants with bilateral symmetric (<10 dB HL difference)sensorineural hearing loss were enrolled in this study. All participants were fitted unilateralhearing aids with speech mapping using the National Acoustic Laboratories-Nonlinear 2formula. After the initial fitting, patients were followed with the 2nd and 3rd fitting at twoweeks and six weeks, respectively, and measured for aided pure tone average (PTA), aidedspeech discrimination score (SDS), the difference between target gain and real ear insertiongain (REIG) using speech mapping and subjective satisfaction via Korean Adaptation of theInternational Outcome Inventory for Hearing Aids (K-IOI-HA) questionnaire before furtherfitting was performed. We analyzed correlation of each parameter at 2nd and 3rd fitting withthe K-IOI-HA score. Results Every sequential aided PTA and SDS at 2nd fitting and 3rd fitting were significantlyimproved after repeated hearing aid fitting (all p<0.01). In the correlation analysis betweenK-IOI-HA and each parameter, the aided PTA and aided SDS did not show significant correlationswith subjective satisfaction from the 2nd and 3rd fittings. But the difference between thetarget gain and R EIG in speech mapping showed significant negative correlations with thesatisfaction scores at various speech level (r=-0.609 to -0.709, all p<0.01). Conclusion Speech mapping using real ear measurement was useful to expect subjectivesatisfaction of hearing aid users and it would be a valuable tool for fine tuning to achieve individualpreferences.

참고문헌 (18)

  1. Kodera K, "Guidelines for the evaluation of hearing aid fitting (2010)", Auris Nasus Larynx, 43(3), pp.217~228 (2016)[DOI]
  2. Yoon TH, "Hearing aid fitting and verification", Korean J Audiol, 2(1), pp.17~22 (1998)
  3. Swan IR, "The value of routine in-the-ear measurement of hearing aid gain", Br J Audiol, 29(5), pp.271~277 (1995)[DOI]
  4. 추호석, "한국어판 International Outcome Inventory for Hearing Aids(IOI-HA)의 표준화: 타당도 및 신뢰도 검증", 대한이비인후-두경부외과학회지, 55(1), pp.20~25 (2012), 대한이비인후과학회
  5. Oh SH, "Current opinion on hearing aids", pp.447~ (2017), Sejong academy
  6. Cho YS, "Clinical Settings for Hearing Aids", Audiol Speech Res, 12(suppl 1), pp.527~532 (2016)
  7. Tecca JE, "Strategies for selecting and verifying hearing aid fittings", pp.88~107 (1994), Thieme Publishing
  8. Valente M, "Reliability and intersubject variability of the real ear unaided response", Ear Hear, 12(3), pp.216~220 (1991)[DOI]
  9. Valente M, "Intratester test-retest reliability of insertion gain measures", Ear Hear, 11(3), pp.181~184 (1990)[DOI]
  10. Hawkins DB, "Examination of two issues concerning functional gain measurements", J Speech Hear Disord, 52(1), pp.56~63 (1987)[DOI]
  11. 조양선, "보청기 클리닉의 운영", 대한이비인후-두경부외과학회지, 53(6), pp.333~339 (2010), 대한이비인후과학회
  12. 정재호, "감각신경성 난청의 재활: 보청기", Hanyang Medical Reviews, 35(2), pp.97~102 (2015), 한양대학교 의과대학[DOI]
  13. Hong SH, "REUR (real ear unaided response) Performed before hearing aid fitting", Korean J Audiol, 1(1), pp.64~69 (1997)
  14. Noh H, "Feasibility of Real Ear Measurement for Hearing Aid Fitting in Preschoolers", Korean J Audiol, 14(3), pp.181~186 (2010)
  15. Moore BCJ, "Speech mapping is a valuable tool for fitting and counseling patients", Hearing Journal, 59(8), pp.26~31 (2006)
  16. Cole WA, "The audioscan RM500 speechmap", DSL fitting system, 1998, pp.3(4), 125~139
  17. Cunningham DR, "Study finds use of Live Speech Mapping reduces follow-up visits and saves money", Hearing Journal, 55(2), pp.43~49 (2002)
  18. Ross T, "How to use live speech mapping as part of a hearing instrument fitting and verification protocol", Hearing Review, 12(6), pp.40~49 (2005)

관련 논문AI추천