Comparison of a Hearing Aid Fitting Formula Based on Korean Acoustic Characteristics and Existing Fitting Formulae
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Purpose: Most existing hearing aid (HA) fitting formulae were developed based on English. However, Korean language has different acoustic characteristics compared to English. This study aimed to develop Korean language-specific hearing aid fitting formula (Hallym Audiology Institute-version 1, HAI-v1) and to compare speech perception, clarity, and overall preference between the HAI-v1 and established fitting formulae [National Acoustic Laboratories’ nonlinear fitting procedure, version 2 (NAL-NL2) and Desired Sensation Level, version 5.0 (DSL5.0)]. Methods: Gains for the HAI-v1 were determined to reach the gain around the medium to the two-thirds portion in the dynamic range of conversational speech level for soft, medium, and loud levels using loudness growth for Koreans who have sensorineural hearing loss (SNHL). Twenty-four people with SNHL participated in this study. Reception thresholds of sentences (RTSs) and preferences (clarity and overall preference) were evaluated, once with HAI-v1 setting, once with NAL-NL2 setting, and once with DSL5.0 setting, in random order. Then, results of RTSs and preferences across HA fitting formulae were compared. Results: There were no statistical differences for RTSs with and without noise in all HA fitting formulae. For clarity, more participants preferred sounds with HAI-v1 or NAL-NL2 than sounds with DSL5.0. For overall preference, more participants preferred sounds with HAI-v1 than sounds with NAL-NL2 or DSL5.0. Conclusion: Results of this study suggest that language-specific HA fitting formula may provide better HA outcomes for people who use different languages.
Abstract
Purpose: Most existing hearing aid (HA) fitting formulae were developed based on English. However, Korean language has different acoustic characteristics compared to English. This study aimed to develop Korean language-specific hearing aid fitting formula (Hallym Audiology Institute-version 1, HAI-v1) and to compare speech perception, clarity, and overall preference between the HAI-v1 and established fitting formulae [National Acoustic Laboratories’ nonlinear fitting procedure, version 2 (NAL-NL2) and Desired Sensation Level, version 5.0 (DSL5.0)]. Methods: Gains for the HAI-v1 were determined to reach the gain around the medium to the two-thirds portion in the dynamic range of conversational speech level for soft, medium, and loud levels using loudness growth for Koreans who have sensorineural hearing loss (SNHL). Twenty-four people with SNHL participated in this study. Reception thresholds of sentences (RTSs) and preferences (clarity and overall preference) were evaluated, once with HAI-v1 setting, once with NAL-NL2 setting, and once with DSL5.0 setting, in random order. Then, results of RTSs and preferences across HA fitting formulae were compared. Results: There were no statistical differences for RTSs with and without noise in all HA fitting formulae. For clarity, more participants preferred sounds with HAI-v1 or NAL-NL2 than sounds with DSL5.0. For overall preference, more participants preferred sounds with HAI-v1 than sounds with NAL-NL2 or DSL5.0. Conclusion: Results of this study suggest that language-specific HA fitting formula may provide better HA outcomes for people who use different languages.
참고문헌 (16)
- Brooks, D. N., "The time course of adaptation to hearing aid use", British Journal of Audiology, 30(1), pp.55~62 (1996)
- Gandour, J., "Perceptual dimensions of tone : Evidence from Cantonese", Journal of Chinese Linguistics, 9(1), pp.20~36 (1981)
- Jang, H. S., "Development of Korean standard sentence lists for sentence recognition tests", Audiology, 4(2), pp.161~177 (2008)
- Jin, I. K., "Dynamic range for speech materials in Korean, English, and Mandarin: A cross-language comparison", Journal of Speech, Language, and Hearing Research, 57(5), pp.2024~2030 (2014)
- 진인기, "The Band-Importance Function for the Korean Standard Sentence Lists for Adults", Journal of Audiology & Otology, 20(2), pp.80~84 (2016), 대한청각학회
- Keidser, G., "NAL-NL2 empirical adjustments", Trends in Amplification, 16(4), pp.211~223 (2012)
- Keidser, G., "The NALNL2 prescription procedure", Audiology Research, 1(1), pp.88~90 (2011)
- Kuo, M. W., "Frequency importance functions for words and sentences in Mandarin Chinese: Implications for hearing aid prescriptions in tonal languages", pp.2013
- Development of a Clinical Protocol for Hearing Instruments. Final Report for the Research Project of Samsung Electronics, "Lee, J. H.", Samsung Advanced Institute of Technology, ~ (2012)
- Moon, S. K., "The Korean hearing in noise test", International Journal of Audiology, 47(6), pp.375~376 (2008)
- Mueller, H. G., "Probe Microphone Measurements : Hearing Aid Selection and Assessment. California" (1992), Singular
- Nilsson, M., "Development of the hearing in noise test for the measurement of speech reception thresholds in quiet and in noise", The Journal of the Acoustical Society of America, 95(2), pp.1085~1099 (1994)
- Noh, H., "Cross-language identification of long-term average speech spectra in Korean and English : Toward a better understanding of the quantitative difference between two languages", Ear and Hearing, 33(3), pp.441~443 (2012)
- Palmer, C. V., "Strategies for Selecting and Verifying Hearing Aid Fittings" (2002), Thieme Medical Publishers
- 박유진, "건청인과 감각신경성난청 성인의 청력역치에 따른 음량증가의 변화", Audiology and Speech Research, 9(1), pp.25~32 (2013), 한국청각언어재활학회
- Scollie, S., "The desired sensation level multistage input", output algorithm, 2005, pp.9(4), 159~197
