Background and Objectives In this study, we introduce our method of hearing aid (HA)verification using real ear measurement (REM). We verified HAs that have gone through thefitting program using speech mapping REM; we then compared the outcome with word recognitionscores (WRS) to evaluate functional gain. Subjects and Method Fifty-six patients of sensorineural hearing loss (81 ears) were enrolledin the study. In REM, if the gap between the target gain of HA and real ear aided response(REAR) was less than 10 dB SPL, fitting was considered successful. In speech audiometry,unaided maximum discrimination score (PB max), unaided WRS at 65 dB HL andaided WRS at 65 dB HL were measured. By comparing PB max and aided WRS at 65 dB HL,patients were sorted into best (n=15), good (n=57), and poorly (n=9) aided groups and analyzedfor the successes of fitting. Fitting was deemed unsuccessful if REAR was ≥10 dB SPLlower than the target value of HA. Results The mean aided WRS at 65 dB HL of best, good and poorly aided groups were85.6%, 77.3%, and 54.2%, respectively. There were statistically significant differences betweenall groups (p=0.019, 0.001, 0.002). The success rates of HA fitting showed significant differencesat 0.5, 0.75, 1, 4 kHz of 55 dB SPL (p=0.023, 0.005, 0.003, 0.014), and at 4 kHz of 65 and75 dB SPL (p=0.004, 0.001). The high WRS group showed sufficient gain at many frequencies. Conclusion Well fitted HAs can provide sufficient increase in speech intelligibility. Usingthe speech mapping REM is a great method to verify fitting of HA.
Abstract
Background and Objectives In this study, we introduce our method of hearing aid (HA)verification using real ear measurement (REM). We verified HAs that have gone through thefitting program using speech mapping REM; we then compared the outcome with word recognitionscores (WRS) to evaluate functional gain. Subjects and Method Fifty-six patients of sensorineural hearing loss (81 ears) were enrolledin the study. In REM, if the gap between the target gain of HA and real ear aided response(REAR) was less than 10 dB SPL, fitting was considered successful. In speech audiometry,unaided maximum discrimination score (PB max), unaided WRS at 65 dB HL andaided WRS at 65 dB HL were measured. By comparing PB max and aided WRS at 65 dB HL,patients were sorted into best (n=15), good (n=57), and poorly (n=9) aided groups and analyzedfor the successes of fitting. Fitting was deemed unsuccessful if REAR was ≥10 dB SPLlower than the target value of HA. Results The mean aided WRS at 65 dB HL of best, good and poorly aided groups were85.6%, 77.3%, and 54.2%, respectively. There were statistically significant differences betweenall groups (p=0.019, 0.001, 0.002). The success rates of HA fitting showed significant differencesat 0.5, 0.75, 1, 4 kHz of 55 dB SPL (p=0.023, 0.005, 0.003, 0.014), and at 4 kHz of 65 and75 dB SPL (p=0.004, 0.001). The high WRS group showed sufficient gain at many frequencies. Conclusion Well fitted HAs can provide sufficient increase in speech intelligibility. Usingthe speech mapping REM is a great method to verify fitting of HA.
참고문헌 (16)
- 2014 national survey for persons with disabilities, "Korea Institute for Health and Social Affairs", Ministry of Health and Welfare, ~ (2014)
- Scollie S, "The desired sensation level multistage input", output algorithm, 2005, pp.9(4), 159~197
- Dillon H, "NAL-NL1 : A new procedure for fitting non-linear hearing aids", Hear J, 52(4), pp.10~16 (1999)
- Ching TYC, "Hearing aid fitting and developmental outcomes of children fit according to either the NAL or DSL prescription: Fitto-target, audibility, speech and language abilities", Int J Audiol, 57(sup2), pp.S41~S54 (2018)
- Yoon TH, "Hearing aid fitting and verification", Korean J Audiol, 2(1), pp.17~22 (1998)
- Aazh H, "The value of routine real ear measurement of the gain of digital hearing aids", J Am Acad Audiol, 18(8), pp.653~664 (2007)
- 조양선, "보청기 클리닉의 운영", 대한이비인후-두경부외과학회지, 53(6), pp.333~339 (2010), 대한이비인후과학회
- Swan IR, "The value of routine in-the-ear measurement of hearing aid gain", Br J Audiol, 29(5), pp.271~277 (1995)
- Aazh H, "The accuracy of matching target insertion gains with open-fit hearing aids", Am J Audiol, 21(2), pp.175~180 (2012)
- 장영수, "프로그램과 실이 측정을 이용한 보청기 적합의 임상적 유용성의 비교", 대한이비인후-두경부외과학회지, 61(12), pp.663~668 (2018), 대한이비인후과학회[DOI]
- Bamford J, "Speech-hearing tests and the spoken language of hearing-impaired children" (1979), Academic Press
- Sullivan JA, "Amplification for listeners with steeply sloping, high-frequency hearing loss", Ear Hear, 13(1), pp.35~45 (1992)
- Amos NE, "Contribution of high frequencies to speech recognition in quiet and noise in listeners with varying degrees of high-frequency sensorineural hearing loss", J Speech Lang Hear Res, 50(4), pp.819~834 (2007)
- Horwitz AR, "Factors affecting the benefits of high-frequency amplification", J Speech Lang Hear Res, 51(3), pp.798~813 (2008)
- Behrens SJ, "Acoustic characteristics of English voiceless fricatives : A descriptive analysis", J Phon, 16(3), pp.295~298 (1988)