Development of a Wearable Pulse Transit Time Monitoring Device

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Objectives: We have developed a non‐intrusive continuous PTT monitoring system, using a wearable device and wireless communication technology. Methods: Pulse transit time (PTT) is a non‐invasive measurement that shows promise in the continuous monitoring of blood pressure (BP) and the assessment of arterial stiffness. It has potential applications in wearable health monitoring devices. Generally, PTT is measured from the electrocardiogram (ECG) Rwave to a characteristic point on the peripheral pulse by photoplethysmography. However, for home healthcare applications, a system needs to be wearable and wireless. ECG and PPG were sampled at 1200 Hz and transmitted to a personal computer (PC) using Bluetooth communications. Heart rate (HR) and PTT were calculated by the PC from the signals received and waveforms of ECG, PPG, PTT and HR were displayed. Results: In this study, we implemented a system that could be adapted to the wrist and measured ECG and a Photoplethysmogram (PPG). Conclusions: The wearable continuous PTT monitoring system developed in this study could be useful in home cardiovascular healthcare.

Abstract

Objectives: We have developed a non‐intrusive continuous PTT monitoring system, using a wearable device and wireless communication technology. Methods: Pulse transit time (PTT) is a non‐invasive measurement that shows promise in the continuous monitoring of blood pressure (BP) and the assessment of arterial stiffness. It has potential applications in wearable health monitoring devices. Generally, PTT is measured from the electrocardiogram (ECG) Rwave to a characteristic point on the peripheral pulse by photoplethysmography. However, for home healthcare applications, a system needs to be wearable and wireless. ECG and PPG were sampled at 1200 Hz and transmitted to a personal computer (PC) using Bluetooth communications. Heart rate (HR) and PTT were calculated by the PC from the signals received and waveforms of ECG, PPG, PTT and HR were displayed. Results: In this study, we implemented a system that could be adapted to the wrist and measured ECG and a Photoplethysmogram (PPG). Conclusions: The wearable continuous PTT monitoring system developed in this study could be useful in home cardiovascular healthcare.

참고문헌 (24)

  1. A. Babchenko, "Increase in pulse transit time to the foot after epidural anaesthesia treatment", Med Biol Eng Comput, 38, pp.674~679 (2000)
  2. D. Pitson, "Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects", Clin Sci, 87, pp.269~273 (1994)
  3. R.P. Smith, "Pulse transit time: an appraisal of potential clinical applications", Thorax, 54, pp.452~458 (1999)
  4. A.V.J. Challoner, "Photoelectric plethysmography for estimating cutaneous blood flow, Non‐invasive Physiological Measurement", pp.125~151 (1979), Academic
  5. E. Tur, "Basal perfusion of the cutaneous microcirculation: measurements as a function of anatomic position", J Invest Dermatol, 81, pp.442~446 (1983)
  6. J. Allen, "Age‐related changes in peripheral pulse timing characteristics at the ears, fingers and toes", J Hum Hypertens, 16, pp.711~717 (2002)
  7. S. O. Yang, "The Effect of Tele‐ Health Service on Knowledge and Family support of Hypertension patients", Journal of Korean Society of Medical Iinformatics, 14(1), pp.75~83 (2008)
  8. G.F. Mitchell, "Changes in arterial stiffness and wave reflection with advancing age in healthy men and women. The Framingham Heart Study", Hypertension, 43, pp.1239~1245 (2004)
  9. J.Y.A. Foo, "Predictive regression equations and clinical uses of peripheral pulse timing characteristics in children", Physiol Meas, 26, pp.317~328 (2005)
  10. J.H. Hong, "A PDA‐ Based Wireless ECG Monitioring System for u‐ Healthcare", Journal of Korean Society of Medical Iinformatics, 12(2), pp.153~159 (2006)
  11. G. Troster, "The agenda of wearable healthcare IMIA Yearbook of Medical Informatics 2005 Ubiquitous Health Care Systems", pp.125~138 (2005), Schattauer
  12. J. Allen, "Photoplethysmography and its application in clinical physiological measurement", Physiol Meas, 28, pp.R1~R39 (2007)
  13. P. Escourrou, "Needs and costs of sleep monitoring", Studies in Health Technology and Informatics, 78, pp.69~85 (2000)
  14. J.Y.A. Foo, "Measurement of pulse transit time using AT90S85 microcontroller", Measurement, 39, pp.505~511 (2006)
  15. R. Fensli, "A Wearable ECG‐recording System for Continuous arrhythmia Monitoring in a Wireless Tele‐Home‐Care Situation", Proceedings of the 18th IEEE Symposium on Computer‐Based Medical Systems (2005)
  16. T. Martin, "Issues in Wearable Computing for Medical Monitoring Applications: A Case Study of a Wearable ECG Monitoring Device", 4th International Symposium on Wearable Computers (2000)
  17. "Mangas HealthGear: A Realtime Wearable System for Monitoring and Analyzing Physiological Signals"[URL]
  18. Y.H. Nam, "Development of remote diagnosis system integrating digital telemetry for medicine", Proceedings of the 20th Annual International Conference of the IEEE Engineering inMedicine and Biology Society (1998)
  19. N. Halin, "The LifeShirt system for wireless patient monitoring in the operating room", J . Telemed Telecare, 11(2), pp.S41~S43 (2005)
  20. K.K. Kim, "A new method for unconstrained pulse arrival time (PAT) measurement on a chair", J. Biomed. Eng. Res, 27(3), pp.83~88 (2006)
  21. K.G. Ng, "Progress on the development of the MediWatch ambulatory blood pressure monitor and related devices", Blood Press Monit, 9, pp.149~165 (2004)
  22. C. Ni Scanaill, "A review of approaches to mobility telemonitoring of the elderly in their living environment", Ann Biomed Eng, 34(4), pp.547~563 (2006)
  23. M. Karunanithi, "Monitoring technology for the elderly patient", Expert Rev Med Devices, 4(2), pp.267~277 (2007)
  24. V. Subramanian, "Clinical and research applications of ambulatory Holter ST‐segment and heart rate monitoring", Am J of Cardiol, 58(4), pp.11B~20B (1986)