본문 바로가기
KERD
논문KCI 등재

A Study on the Estimation of Continuous Blood Pressure using PTT and Biometric Parameters

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

In this paper, we propose a subject-independent regression model to estimate systolic blood pressures (SBP) conveniently and continuously. There have been several researches on estimating SBP with pulse transit time (PTT) and they showed promising results. However, previous studies used only PTT as the estimation parameter, and their models were generated with just one person’s PTT data which is not applicable to estimating other person’s SBP. Therefore, we collected several additional biometric parameters with 202 healthy subjects. After statistical analysis of measured biometric parameters with SBP, we chose final estimating parameters including PTT to generate a multiple linear regression model for estimating SBP. Comparing the results of our study with approvable standards of automated sphygmomanometers developed by Association for the Advancement of Medical Instrumentation and approved by American National Standards Institute (ANSI/AAMI) indicates that our proposed method for continuously blood pressures monitoring gives an acceptable error.

Abstract

In this paper, we propose a subject-independent regression model to estimate systolic blood pressures (SBP) conveniently and continuously. There have been several researches on estimating SBP with pulse transit time (PTT) and they showed promising results. However, previous studies used only PTT as the estimation parameter, and their models were generated with just one person’s PTT data which is not applicable to estimating other person’s SBP. Therefore, we collected several additional biometric parameters with 202 healthy subjects. After statistical analysis of measured biometric parameters with SBP, we chose final estimating parameters including PTT to generate a multiple linear regression model for estimating SBP. Comparing the results of our study with approvable standards of automated sphygmomanometers developed by Association for the Advancement of Medical Instrumentation and approved by American National Standards Institute (ANSI/AAMI) indicates that our proposed method for continuously blood pressures monitoring gives an acceptable error.

참고문헌 (18)

  1. "Medical Instrument: Application and decision", pp.287~331 (1998), WILEY
  2. "Introduction to Biomedical Equipment Technology", pp.234~304 (2001), Prentice Hall
  3. "Pulse transit time as an indicator of Arterial Blood Pressure", 18, pp.71~75 (1981)
  4. "The rela- tionship between arterial blood pressure and pulse transit time during dynamic and static exercise", 21, pp.521~527 (1984)
  5. "Non-invasive blood pressure data acquisition employing pulse transit time detection", 3, pp.1308~1309 (1996)
  6. "Continuous blood pressure monitoring using pulse wave delay", 4, pp.3171~3174 (2001)
  7. "Aortic-radial pulse transit time and ECG Q-wave to radial pulse wave interval as indices of beat by beat blood pressure change", 20, pp.21~28 (1983)
  8. "A Clinical evaluation of continuous noninvasive blood pressure monitoring: Accuracy and tracking capability", 11, pp.245~252 (1995)
  9. "The velocity of the pulse wave in man", pp.298~306 (1922), Proceedings of the Royal Society
  10. "A Study on Estimation of Systolic Blood Pressure using PTT", 25(6), pp.431~438 (2004)
  11. "Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger", 19, pp.139~145 (1985)
  12. "Effect of peripheral vasoconstriction on the beat-to-beat measurement of finger blood pressure" (2000)
  13. "Influence of height, leg and trunk length on pulse pressure, systolic and diastolic blood pressure", (21), pp.527~543 (2003)
  14. "Age effects upon the harmonic structure of human blood pressure in clinical health", pp.238~243 (1989), Minneapolis
  15. "Pulse Transit Time and Blood Pressure: An Intensive Analysis", 20(1), pp.45~49 (1983)
  16. "Multivariate Analysis by Korean SPSS 10.0" (2003), Hyung- Seol Press
  17. "Medical Statistical Analysis" (2002), SPSS Aca- demy
  18. "Manual, electronic, or automated sphygmo-manometers" (2003), Association for the Advancement of Medical Instru- mentation

관련 논문AI추천