디지털 센서 장비를 적용한 가슴 압박의 질 변화
Changes in the quality of chest compressions applying a digital sensor device
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose : The purpose of this study is to demonstrate the effectiveness of using a digital sensor device during CPR by analyzing the results from that chest compressions with a digital sensor device are applied to cardiac arrest patients. Methods : This study analyzed the results from the experiment that 42 people were selected randomly among Korean 119 rescuers, and they divided into the experimental group using a digital sensor device and the control group only using their hands, then they had been observed to conduct chest- compressions to mannequins for 10 minutes. Results : The results were found that compression depth in both the control and experimental group was gradually decreased over time, but the experimental group not only kept the depth but also maintained the speed of chest-compressions close to 100 times a minute. In addition, due to the use of the digital sensor device, the insufficient recoil ratio of chest-compressions was significantly reduced. Conclusion : The results show that conducting chest-compressions with a digital sensor device keeps the compression-death, maintains the speed of chest-compression properly and makes the insufficient relaxation ratio of chest-compressions reduce significantly.
Abstract
Purpose : The purpose of this study is to demonstrate the effectiveness of using a digital sensor device during CPR by analyzing the results from that chest compressions with a digital sensor device are applied to cardiac arrest patients. Methods : This study analyzed the results from the experiment that 42 people were selected randomly among Korean 119 rescuers, and they divided into the experimental group using a digital sensor device and the control group only using their hands, then they had been observed to conduct chest- compressions to mannequins for 10 minutes. Results : The results were found that compression depth in both the control and experimental group was gradually decreased over time, but the experimental group not only kept the depth but also maintained the speed of chest-compressions close to 100 times a minute. In addition, due to the use of the digital sensor device, the insufficient recoil ratio of chest-compressions was significantly reduced. Conclusion : The results show that conducting chest-compressions with a digital sensor device keeps the compression-death, maintains the speed of chest-compression properly and makes the insufficient relaxation ratio of chest-compressions reduce significantly.
참고문헌 (15)
- Berg RA, "Part 5: Adult basic life support : 2010American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care", Circulation, 122(18 suppl 3), pp.685~705 (2010)
- Berg RA, "Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest", Circulation, 104(20), pp.2465~2470 (2001)
- Yu T, "Adverse outcomes of interrupted precordial compression during automated defibrillation", Circulation, 106(3), pp.368~372 (2002)
- "2013 Fire administration data and statistics" (2013)[URL]
- Yoo IS, "Decay in quality of closed-chest compression over time on CPR", J Korean Soc Emerg Med, 9(1), pp.34~38 (1998)
- 김용범, "30:2와 15:2 압박 대 환기비가 1인 구조자의 피로도와 심폐소생술의 질에 미치는영향", 대한응급의학회지, 17(6), pp.519~527 (2006), 대한응급의학회
- 나준호, "일반인의 심폐소생술 시 시간의 흐름에 따른 구조자의 피로에 의한 가슴압박의 질 변화와 이와 관련된 구조자의 특성; 마네킹을 이용한 가상 연구", 대한응급의학회지, 22(5), pp.431~437 (2011), 대한응급의학회
- Wik L, "Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest", JAMA, 293(3), pp.299~304 (2005)
- Chandra N, "Simultaneous chest compression and ventilation at high airway pressure during cardiopulmonary resuscitation", Lancet, 1(8161), pp.175~178 (1980)
- Halperin HR, "Vest inflation without simultaneous ventilation during cardiac arrest in dogs: improved survival from prolonged cardiopulmonary resuscitation", Circulation, 74(6), pp.1407~1415 (1986)
- Halperin HR, "A preliminary study of cardiopulmonary resuscitation by circumferential compression of the chest with use of a pneumatic vest", N Engl J Med, 329(11), pp.762~768 (1993)
- Timerman S, "Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest", Resuscitation, 61(3), pp.273~280 (2004)
- 양현모, "심페소생술 시행 시에 휴대용 압박 센서 활용이 흉부압박의 질에 미치는 영향: 마네킹 기반 시뮬레이션 연구", 한국산학기술학회논문지, 14(2), pp.744~750 (2013), 한국산학기술학회[DOI]
- 박덕, "심폐소생술 시행 시에 실시간 시청각 되먹임 감시장비의 사용이 흉부압박의 질에미치는 영향: 마네킨 모델을 이용한 무작위 시뮬레이션 연구", 대한응급의학회지, 19(1), pp.37~44 (2008), 대한응급의학회
- Abella BS, "CPR quality improvement during in hospital cardiac arrest using a real-time audiovisual feedback system", Resuscitation, 73(1), pp.54~61 (2007)