디지털 센서 장비를 적용한 가슴 압박의 질 변화

Changes in the quality of chest compressions applying a digital sensor device

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose : The purpose of this study is to demonstrate the effectiveness of using a digital sensor device during CPR by analyzing the results from that chest compressions with a digital sensor device are applied to cardiac arrest patients. Methods : This study analyzed the results from the experiment that 42 people were selected randomly among Korean 119 rescuers, and they divided into the experimental group using a digital sensor device and the control group only using their hands, then they had been observed to conduct chest- compressions to mannequins for 10 minutes. Results : The results were found that compression depth in both the control and experimental group was gradually decreased over time, but the experimental group not only kept the depth but also maintained the speed of chest-compressions close to 100 times a minute. In addition, due to the use of the digital sensor device, the insufficient recoil ratio of chest-compressions was significantly reduced. Conclusion : The results show that conducting chest-compressions with a digital sensor device keeps the compression-death, maintains the speed of chest-compression properly and makes the insufficient relaxation ratio of chest-compressions reduce significantly.

Abstract

Purpose : The purpose of this study is to demonstrate the effectiveness of using a digital sensor device during CPR by analyzing the results from that chest compressions with a digital sensor device are applied to cardiac arrest patients. Methods : This study analyzed the results from the experiment that 42 people were selected randomly among Korean 119 rescuers, and they divided into the experimental group using a digital sensor device and the control group only using their hands, then they had been observed to conduct chest- compressions to mannequins for 10 minutes. Results : The results were found that compression depth in both the control and experimental group was gradually decreased over time, but the experimental group not only kept the depth but also maintained the speed of chest-compressions close to 100 times a minute. In addition, due to the use of the digital sensor device, the insufficient recoil ratio of chest-compressions was significantly reduced. Conclusion : The results show that conducting chest-compressions with a digital sensor device keeps the compression-death, maintains the speed of chest-compression properly and makes the insufficient relaxation ratio of chest-compressions reduce significantly.

참고문헌 (15)

  1. Berg RA, "Part 5: Adult basic life support : 2010American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care", Circulation, 122(18 suppl 3), pp.685~705 (2010)
  2. Berg RA, "Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest", Circulation, 104(20), pp.2465~2470 (2001)
  3. Yu T, "Adverse outcomes of interrupted precordial compression during automated defibrillation", Circulation, 106(3), pp.368~372 (2002)
  4. "2013 Fire administration data and statistics" (2013)[URL]
  5. Yoo IS, "Decay in quality of closed-chest compression over time on CPR", J Korean Soc Emerg Med, 9(1), pp.34~38 (1998)
  6. 김용범, "30:2와 15:2 압박 대 환기비가 1인 구조자의 피로도와 심폐소생술의 질에 미치는영향", 대한응급의학회지, 17(6), pp.519~527 (2006), 대한응급의학회
  7. 나준호, "일반인의 심폐소생술 시 시간의 흐름에 따른 구조자의 피로에 의한 가슴압박의 질 변화와 이와 관련된 구조자의 특성; 마네킹을 이용한 가상 연구", 대한응급의학회지, 22(5), pp.431~437 (2011), 대한응급의학회
  8. Wik L, "Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest", JAMA, 293(3), pp.299~304 (2005)
  9. Chandra N, "Simultaneous chest compression and ventilation at high airway pressure during cardiopulmonary resuscitation", Lancet, 1(8161), pp.175~178 (1980)
  10. Halperin HR, "Vest inflation without simultaneous ventilation during cardiac arrest in dogs: improved survival from prolonged cardiopulmonary resuscitation", Circulation, 74(6), pp.1407~1415 (1986)
  11. Halperin HR, "A preliminary study of cardiopulmonary resuscitation by circumferential compression of the chest with use of a pneumatic vest", N Engl J Med, 329(11), pp.762~768 (1993)
  12. Timerman S, "Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest", Resuscitation, 61(3), pp.273~280 (2004)
  13. 양현모, "심페소생술 시행 시에 휴대용 압박 센서 활용이 흉부압박의 질에 미치는 영향: 마네킹 기반 시뮬레이션 연구", 한국산학기술학회논문지, 14(2), pp.744~750 (2013), 한국산학기술학회[DOI]
  14. 박덕, "심폐소생술 시행 시에 실시간 시청각 되먹임 감시장비의 사용이 흉부압박의 질에미치는 영향: 마네킨 모델을 이용한 무작위 시뮬레이션 연구", 대한응급의학회지, 19(1), pp.37~44 (2008), 대한응급의학회
  15. Abella BS, "CPR quality improvement during in hospital cardiac arrest using a real-time audiovisual feedback system", Resuscitation, 73(1), pp.54~61 (2007)

관련 논문AI추천

의료인들이 제공하는 가슴 압박의 질에 대한 가상 연구강지훈, 고재욱, 김경욱, 김인병, 여준모, 정상원, 좌민홍대한중환자의학회 · Acute and Critical Care2011 · 제26권 제2호가슴압박만 하는 심폐소생술과 30:2 표준 심폐소생술 방법에 의한 가슴압박 질의 비교류지호, 민문기사단법인 한국응급구조학회 · 한국응급구조학회지2015 · 제19권 제3호병원 전 단계 시뮬레이션 심정지 상황에서 AutoPulseTM 장치를 이용한 흉부 압박과 수기 흉부 압박에 대한 비교연구고장식, 김근희, 김수태, 김용석, 임세영, 조병준, 황성훈한국컴퓨터정보학회 · 한국컴퓨터정보학회논문지2018 · 제23권 제10호구조자 특성별 심폐소생술 지속시간에 따른 질 변화유순규, 최혜경사단법인 한국응급구조학회 · 한국응급구조학회지2012 · 제16권 제3호병원내 심폐소생술 모형에서 환자와 구조자의 거리 및 위치에 따른 가슴압박의 질 비교김건남, 류소연, 장진영, 최성우사단법인 한국응급구조학회 · 한국응급구조학회지2014 · 제18권 제1호가슴압박소생술과 표준심폐소생술의 가슴압박 품질, 심폐소생술 수행 의지 및 자신감 비교 분석안신, 김미영, 김수현, 박주현, 송재관, 신인선, 오윤희, 오정민, 조은희한국간호시뮬레이션학회 · 한국간호시뮬레이션학회지2020 · 제8권 제2호

이 간행물의 다른 논문 (8건)