의료인들이 제공하는 가슴 압박의 질에 대한 가상 연구
A Simulation Study for Quality of Chest Compression Provided by Health Personnel
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Background: Effective chest compression may improve the return of spontaneous circulation and neurologic outcome in arrest victims. For fear of rescuer’s fatigue, guidelines for cardiopulmonary resuscitation (CPR) recommended that chest compression (CC) should be switched every 2 minutes, but there is little evidence. We investigated whether health personnel could provide consistent quality of CC for 2 minutes. Methods: We recruited prospectively health personnel working on one university hospital. On the day assigned randomly, CPR performance data was collected with use of CPR recording technology. Quality of CPR was calculated every 30 seconds interval. To identify the quality decay, we used repeated measure analysis of variance with SPSS 17.0 for analysis. Results: We analyzed 8,485 CCs performed by 41 subjects. Total number of CC decayed between 90 to 120 seconds (51.6 ± 3.3 to 50.8 ± 3.5, p = 0.020) within recommended range. The ratio of correct depth CC decayed between 90 to 120 seconds, falling from 83.4 ± 24.9% to 68.3 ± 38.4% (p = 0.002). The ratio of low depth CC increased significantly over time (10.2 ± 20.7% to 31.3 ± 38.5%, p < 0.001). Conclusions: Health personnel may provide adequate number of CC for 2 minutes. But, the number of correct depth CC may decay between 90 to 120 seconds. Also the number of low depth CC may increase over time.
Abstract
Background: Effective chest compression may improve the return of spontaneous circulation and neurologic outcome in arrest victims. For fear of rescuer’s fatigue, guidelines for cardiopulmonary resuscitation (CPR) recommended that chest compression (CC) should be switched every 2 minutes, but there is little evidence. We investigated whether health personnel could provide consistent quality of CC for 2 minutes. Methods: We recruited prospectively health personnel working on one university hospital. On the day assigned randomly, CPR performance data was collected with use of CPR recording technology. Quality of CPR was calculated every 30 seconds interval. To identify the quality decay, we used repeated measure analysis of variance with SPSS 17.0 for analysis. Results: We analyzed 8,485 CCs performed by 41 subjects. Total number of CC decayed between 90 to 120 seconds (51.6 ± 3.3 to 50.8 ± 3.5, p = 0.020) within recommended range. The ratio of correct depth CC decayed between 90 to 120 seconds, falling from 83.4 ± 24.9% to 68.3 ± 38.4% (p = 0.002). The ratio of low depth CC increased significantly over time (10.2 ± 20.7% to 31.3 ± 38.5%, p < 0.001). Conclusions: Health personnel may provide adequate number of CC for 2 minutes. But, the number of correct depth CC may decay between 90 to 120 seconds. Also the number of low depth CC may increase over time.
참고문헌 (15)
- Paradis NA, "perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitation", JAMA, 263, pp.1106~1113 (1990)
- Edelson DP, "Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest", Resuscitation, 71, pp.137~145 (2006)
- Ornato JP, "The effect of applied chest compression force on systemic arterial pressure and end-tidal carbon dioxide concentration during CPR in human beings", Ann Emerg Med, 18, pp.732~737 (1989)
- ECC Committee, "Subcommittees and Task Forces of the American Heart Association: 2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care", Circulation, 112(24), pp.IV1~203 (2005)
- Abella BS, "Chest compression rates during cardiopulmonary resuscitation are suboptimal: a prospective study during in-hospital cardiac arrest", Circulation, 111, pp.428~434 (2005)
- Hightower D, "Decay in quality of closed-chest compressions over time", Ann Emerg Med, 26, pp.300~303 (1995)
- Ochoa FJ, "The effect of rescuer fatigue on the quality of chest compressions", Resuscitation, 37, pp.149~152 (1998)
- Ashton A, "Effect of rescuer fatigue on performance of continuous external chest compressions over 3 min", Resuscitation, 55, pp.151~155 (2002)
- Bjørshol CA, "Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model", Resuscitation, 77, pp.95~100 (2008)
- Riera SQ, "The physiological effect on rescuers of doing 2 min of uninterrupted chest compressions", Resuscitation, 74, pp.108~112 (2007)
- Sugerman NT, "Rescuer fatigue during actual in-hospital cardiopulmonary resuscitation with audiovisual feedback: a prospective multicenter study", Resuscitation, 80, pp.981~984 (2009)
- 박 덕, "심폐소생술 시행 시에 실시간 시청각 되먹임 감시장비의 사용이 흉부압박의 질에미치는 영향: 마네킨 모델을 이용한 무작위 시뮬레이션 연구", 대한응급의학회지, 19(1), pp.37~44 (2008), 대한응급의학회
- Neumar RW, "Part 8: adult advanced cardiovascular life support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care", Circulation, 122(3), pp.S729~767 (2010)
- Berg RA, "Part 5: adult basic life support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care", Circulation, 122(3), pp.S685~705 (2010)
- Neaton JD, "Impact of the Hawthorne effect in a longitudinal clinical study: the case of anesthesia", Control Clin Trials, 21, pp.381~382 (2000)