본문 바로가기
KERD
논문KCI 등재

Solvent-free determination of BTEX in water using repetitive membrane extraction followed by GC-MS

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류화학

초록

An analytical method for solvent-free determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using repetitive membrane extractions coupled to cryofocusing and GC-MS was derived. BTEX compounds that permeated through a nonporous silicone membrane from the aqueous phase and evaporated into the acceptor phase were purged into a cryofocusing trap (-100 ℃) with helium gas. The BTEX compounds,thus enriched in the trap, were thermally desorbed into a capillary column GC and detected using an MS. The flow rate of the donor phase (30 mL water) was set at 10 mL/min, and membrane extractions, accomplished by returning the water drained from the extraction module to the sample container, were repeated three times at 20 ± 2 ℃. Although recoveries (%) were variable, from the highest for benzene (approximately 80%) to the lowest for ethylbenzene and xylenes (3.5-10%), the method showed satisfactory precision (RSD 2.2-10%)with good-linearity calibration curves (r^2 0.9976-0.9997 in 1-100 μg/L range) for all of the compounds. The method detection limits (MDLs) ranged from 0.16 to 1.8 μg/L. The results showed the method’s advantages such as short analysis time and overall simplicity without solvent compared to the conventional techniques.

Abstract

An analytical method for solvent-free determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using repetitive membrane extractions coupled to cryofocusing and GC-MS was derived. BTEX compounds that permeated through a nonporous silicone membrane from the aqueous phase and evaporated into the acceptor phase were purged into a cryofocusing trap (-100 ℃) with helium gas. The BTEX compounds,thus enriched in the trap, were thermally desorbed into a capillary column GC and detected using an MS. The flow rate of the donor phase (30 mL water) was set at 10 mL/min, and membrane extractions, accomplished by returning the water drained from the extraction module to the sample container, were repeated three times at 20 ± 2 ℃. Although recoveries (%) were variable, from the highest for benzene (approximately 80%) to the lowest for ethylbenzene and xylenes (3.5-10%), the method showed satisfactory precision (RSD 2.2-10%)with good-linearity calibration curves (r^2 0.9976-0.9997 in 1-100 μg/L range) for all of the compounds. The method detection limits (MDLs) ranged from 0.16 to 1.8 μg/L. The results showed the method’s advantages such as short analysis time and overall simplicity without solvent compared to the conventional techniques.

참고문헌 (22)

  1. Hylton, K., , J. Chromatogr. A, 1152, pp.199~214 (2007)
  2. Biziuk, M., , J. Chromatogr. A, 733, pp.417~448 (1996)
  3. Kolb, B., , J. Chromatogr. A, 842, pp.163~205 (1999)
  4. Louter, A. J. H., , J. Chromatogr. A, 842, pp.391~426 (1999)
  5. Ouyanga, G., , Trends Anal. Chem, 25, pp.692~703 (2006)
  6. David, F., , J. Chromatogr. A, 1152, pp.54~69 (2007)
  7. Cordero, B. M., , J. Chromatogr. A, 902, pp.195~204 (2000)
  8. Blanchard, R. D., , Anal. Chem, 56, pp.1621~1624 (1984)
  9. Zhang, G.-Z., , J. Environ. Sci. Health, A24, pp.279~295 (1989)
  10. Blanchard, R. D., , Anal. Chem, 57, pp.2349~2351 (1985)
  11. Zhang, G.-Z., , J. Environ. Sci. Health, A24, pp.1011~1024 (1989)
  12. Frantz, D. D., , J. Environ. Sci. Health, A34, pp.695~704 (1999)
  13. Köller, G., , Chromatographia, 57, pp.S-229~S-233 (2003)
  14. Pratt, K. F., , Anal. Chem, 64, pp.2107~2110 (1992)
  15. Xu, Y. H., , J. Chromatogr. A, 688, pp.171~180 (1994)
  16. Hauser, B., , J. Chromatogr. A, 909, pp.3~21 (2001)
  17. Sae-Khow, O., , J. Chromatogr. A, 1217, pp.2736~2746 (2010)
  18. Maden, A. J., , Anal. Chem, 68, pp.1805~1811 (1996)
  19. Hauser, B., , J. High Resol. Chromatogr, 22, pp.205~212 (1999)
  20. Yang, M. J., , Anal. Chem, 66, pp.1339~1346 (1994)
  21. "40 Code of Federal Register Appendix B to Part 136: Definition and Procedure for the Determination of the Method Detection Limit - Revision 1.11", ~ (1994)
  22. "United States Environmental Protection Agency Method 524.3: Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography", Mass Spectrometry – Version 1.0, 2009

관련 논문AI추천

이 간행물의 다른 논문 (9건)