지표수에서 GC/MS에 의한 25개 준휘발성유기화합물의 극미량 분석
Trace level analysis of 25 semi-volatile organic compounds in surface water by gas chromatography-mass spectrometry
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
A gas chromatography-mass spectrometric (GC-MS) method was developed for determining 25 semivolatile organic compounds in water. A 1.0 L water sample was placed in a separatory funnel and saturated with NaCl, and the solution was extracted two times with 40 mL of methylene chloride. Under the established condition, the linear quantification range was 0.02-800 ng/L and the relative standard deviation was less than 15%. The method was used to analyze 16 surface water samples collected from various regions in Gum-River. The samples revealed SVOC concentrations in the range of 0.02-96.8 ng/L. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples. The developed method may be valuable for monitoring SVOCs in water.
Abstract
A gas chromatography-mass spectrometric (GC-MS) method was developed for determining 25 semivolatile organic compounds in water. A 1.0 L water sample was placed in a separatory funnel and saturated with NaCl, and the solution was extracted two times with 40 mL of methylene chloride. Under the established condition, the linear quantification range was 0.02-800 ng/L and the relative standard deviation was less than 15%. The method was used to analyze 16 surface water samples collected from various regions in Gum-River. The samples revealed SVOC concentrations in the range of 0.02-96.8 ng/L. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples. The developed method may be valuable for monitoring SVOCs in water.
참고문헌 (17)
- R. Kamens, , Environ. Sci. & Technol, 29, pp.43~50 (1995)
- D. C. G. Muir, , Environ. Sci. & Technol, 30, pp.3609~3617 (1996)
- S. Dasgupta, , J. Chromatogr. A, 1218(38), pp.6780~6791 (2011)
- F. M. Ali, , Microchim. Acta, 172(3), pp.465~470 (2011)
- J. Wu, , J. Chromatogr. A, 1217(41), pp.6327~6333 (2010)
- Y. Li, , J. Chromatogr. A, 1176(1), pp.223~230 (2007)
- J. Hong, , J. Chromatogr. A, 1038(1), pp.27~35 (2004)
- M. V. Russo, , Chromatographia, 52(1), pp.93~98 (2000)
- P. S. H. Wong, , Anal. Chim. Acta, 310(3), pp.387~398 (1995)
- Y. Huang, , J. Chromatogr. A, 1140(1), pp.35~43 (2007)
- R. Boussahel, , Wat. Res, 36(7), pp.1909~1911 (2002)
- US Environmental Protection Agency, "Method 610", ~ (1991)
- National Recommended Water Quality Criteria, "US Environmental Protection Agency", EPA, ~, pp.EPA-822-R-02-047 (2002)
- 이인정, "낙동강 수계 배출원별 유해물질 오염실태 조사", 한국환경분석학회지, 14(3), pp.128~136 (2011), 한국환경분석학회
- W. J. G. M. Peijnenbur, , Ecotoxicol. Environ. Safe, 63, pp.204~215 (2006)
- Z. Xie, , Atmos. Environ, 39, pp.3209~3219 (2005)
- S. Y. Yuan, , Chemosphere, 49, pp.1295~1299 (2002)
