본문 바로가기
KERD
논문KCI 등재

HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류화학

초록

A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 °C in a headspace vial and adsorbed on 85 μm carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 μg/L. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

Abstract

A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 °C in a headspace vial and adsorbed on 85 μm carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 μg/L. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

참고문헌 (30)

  1. "Directive 2004", 42, 13, pp.EC[DOI]
  2. R. M. Cavalcante, , Microchem. J, 96(2), pp.337~343 (2010)
  3. F. Ruiz-Bevia, , Anal. Chim. Acta, 632(2), pp.304~314 (2009)
  4. C. V. Antoniou, , J. Chromatogr. A, 1132(1), pp.310~314 (2006)
  5. M. K. Zanjani, , J. Hazard. Mat, 136(3), pp.714~720 (2006)
  6. M. A. Mottaleb, , J. Environ. Sci, 16(3), pp.497~501 (2004)
  7. X. Li, , Int. J. Environ. Anal. Chem, 84(9), pp.633~645 (2004)
  8. H. Liu, , Talanta, 80, pp.903~908 (2009)
  9. G. J. Lee, , Bull. Kor. Chem. Soc, 22(2), pp.171~178 (2001)
  10. T. Huybrechts, , J. Chromatogr. A, 893(2), pp.367~382 (2000)
  11. V. I. Safarova, , J. Chromatogr. B, 800, pp.325~330 (2004)
  12. M. Petri, , J. Environ. Manage, 91, pp.142~148 (2009)
  13. Missaoui Inès, , J. Chromatogr. Sci, 47(4), pp.257~262 (2009)
  14. C. Aeppli, , J. Chromatogr. A, 1181, pp.116~124 (2008)
  15. P. Bocchini, , Rapid Commun. Mass Spectrom, 13, pp.2133~2139 (1999)
  16. C. V. Antoniou, , J. Chromatogr. A, 1132, pp.310~314 (2006)
  17. A. A. M. Hassan, , Toxicol. Environ. Chem, 55, pp.73~81 (1996)
  18. M. A. Stack, , Chemosphere, 41, pp.1821~1826 (2000)
  19. B. Pons, , Int. J. Environ. Anal. Chem, 83, pp.495~506 (2003)
  20. V. H. Niri, , J. Chromatogr. A, 1201, pp.222~227 (2008)
  21. G. Pecoraino, , Wat. Res, 42, pp.3563~3577 (2008)
  22. A. D. Guimaraes, , Int. J. Environ. Anal. Chem, 88, pp.151~164 (2008)
  23. N. Jakubowska, , J. Chromatogr. A, 1216, pp.422~441 (2009)
  24. N. Jakubowska, , J. Chromatogr. Sci, 47(8), pp.689~693 (2009)
  25. M. I. Cervera, , Anal. Chim. Acta, 704(1), pp.87~97 (2011)
  26. M. A. Jochmann, , Anal. Bioanal. Chem, 387(6), pp.2163~2174 (2007)
  27. S. Nakamura, , Anal. Chim. Acta, 548(1), pp.79~85 (2005)
  28. 박신영, "HS-SPME 방식에 기초한 물중 VOC 성분의 분석기법에 대한 연구 : 3가지 실험 조건의 변화와 분석감도의 관계", 분석과학, 21(2), pp.93~101 (2008), 한국분석과학회
  29. Ó. Ezquerro, , J. Chromatogr. A, 1035, pp.17~22 (2004)
  30. National Recommended Water Quality Criteria, "US Environmental Protection Agency", EPA, ~, pp.EPA-822-R-02-047 (2002)

관련 논문AI추천

이 간행물의 다른 논문 (11건)