"Purpose: This study aimed to assess the marginal and internal fit of interim crowns fabricated using artificial intelligence (AI)-based dental computer-aided design (CAD) software. Materials and Methods: The right maxillary first molar was prepared for an interim crown. Scan files were obtained using a desktop scanner and exported to three dental CAD software programs: a conventional software and two AI-based dental programs. A uniform cement gap of 60 μm was set across all software, and 10 interim crowns were designed. The crowns were fabricated using a 3D printer, and their marginal and internal fit was evaluated using the silicone replication technique. Statistical analysis was performed using the Kruskal-Wallis test and post hoc analysis (α = 0.05). Results: A significant difference in marginal fit was observed among the three dental CAD software programs (P < 0.05). The marginal gap produced by 3Shape was significantly greater than that of the two AI-based programs (P < 0.05). No significant differences were observed in most areas regarding internal fit (P > 0.05), although Single-Pro exhibited a significantly larger occlusal gap (P < 0.05). Conclusion: The interim crowns fabricated using Dentbird and Single-Pro demonstrated excellent marginal fit. However, further refinement is necessary, as the occlusal area of the internal fit in Single-Pro exhibited a comparatively larger gap."

Abstract

"Purpose: This study aimed to assess the marginal and internal fit of interim crowns fabricated using artificial intelligence (AI)-based dental computer-aided design (CAD) software. Materials and Methods: The right maxillary first molar was prepared for an interim crown. Scan files were obtained using a desktop scanner and exported to three dental CAD software programs: a conventional software and two AI-based dental programs. A uniform cement gap of 60 μm was set across all software, and 10 interim crowns were designed. The crowns were fabricated using a 3D printer, and their marginal and internal fit was evaluated using the silicone replication technique. Statistical analysis was performed using the Kruskal-Wallis test and post hoc analysis (α = 0.05). Results: A significant difference in marginal fit was observed among the three dental CAD software programs (P < 0.05). The marginal gap produced by 3Shape was significantly greater than that of the two AI-based programs (P < 0.05). No significant differences were observed in most areas regarding internal fit (P > 0.05), although Single-Pro exhibited a significantly larger occlusal gap (P < 0.05). Conclusion: The interim crowns fabricated using Dentbird and Single-Pro demonstrated excellent marginal fit. However, further refinement is necessary, as the occlusal area of the internal fit in Single-Pro exhibited a comparatively larger gap."

관련 논문AI추천

Fit accuracy of complete crowns fabricated by generative artificial intelligence design: a comparative clinical study타우 타우 윈, 김소연, 김종은, 이두형, 조석환, Hang-Nga Mai, Jekita Kaenploy, Viritpon Srimaneepong대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제4호Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system이규복, 이두형, 이완선대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호Verification of the accuracy and design time of crowns designed with artificial intelligenceErika Inoue, Katsuhiko Kimoto, Kazuhide Seimiya, Koudai Nagata, Mihoko Atsumi, Noriyuki Hoshi, Shinji Kuroda, Toshifumi Nakashizu대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제1호Marginal and internal fit of 3D printed provisional crowns according to build directions공현준, 김유리, 류지은, 장훈상, 정지혜대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Comparison of marginal and internal fit of zirconia crowns fabricated by three-dimensional printing with different offset parameters: A preliminary pilot study김소연, 김욱태, 이규복, 이지민, 장경준, 손큰바다대한치과의사협회 · 대한치과의사협회지2025 · 제63권 제5호Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study강신영, 김지환, 유승규, 유승민, 이범일대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호

이 간행물의 다른 논문 (9건)