본문 바로가기
KERD
논문KCI 등재

Fit accuracy of complete crowns fabricated by generative artificial intelligence design: a comparative clinical study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. Designing restorations remains challenging because the process is time-consuming and requires operator skill and experience. This clinical study evaluated the fit accuracy of polymerized complete crowns fabricated using a web-based 3D generative artificial intelligence design (GAID) method compared to crowns fabricated using a conventional computer-aided design (CCAD) method. MATERIALS AND METHODS. Sixty-two patients requiring complete crowns in maxillary and mandibular premolars and molars were enrolled. After tooth preparation, digital impressions were taken using an intraoral scanner. Two crowns per patient were designed: one used a web-based automatic 3D GAID software program, and the other used a standard human-driven CCAD software program. The crowns were 3D-printed and delivered to the patients. Marginal and internal discrepancies and occlusal contacts were evaluated using a digital triple scan technique. Statistical analysis used two one-sided t-tests for paired samples to assess crown accuracy in both methods (α = .05). RESULTS. Marginal gaps of crowns made by both methods showed equivalence in the buccal, mesial, and distal regions; however, in the lingual region, the GAID method produced higher marginal discrepancies (P > .001). Regarding internal gaps, no significant difference was observed between the two methods. Crowns produced by the GAID method exhibited larger occlusal discrepancies than those made by the CCAD method (P < .001). CONCLUSION. The fit accuracy of crowns fabricated using generative artificial intelligence was equivalent to those produced using the manual-input computer design method when the margins were well defined. While marginal and occlusal discrepancies were within clinically acceptable range, careful attention must be given to automated design outcomes, considering various tooth preparation shapes, anatomical structures, and clinical variations. [J Adv Prosthodont 2025;17:224-34]

Abstract

PURPOSE. Designing restorations remains challenging because the process is time-consuming and requires operator skill and experience. This clinical study evaluated the fit accuracy of polymerized complete crowns fabricated using a web-based 3D generative artificial intelligence design (GAID) method compared to crowns fabricated using a conventional computer-aided design (CCAD) method. MATERIALS AND METHODS. Sixty-two patients requiring complete crowns in maxillary and mandibular premolars and molars were enrolled. After tooth preparation, digital impressions were taken using an intraoral scanner. Two crowns per patient were designed: one used a web-based automatic 3D GAID software program, and the other used a standard human-driven CCAD software program. The crowns were 3D-printed and delivered to the patients. Marginal and internal discrepancies and occlusal contacts were evaluated using a digital triple scan technique. Statistical analysis used two one-sided t-tests for paired samples to assess crown accuracy in both methods (α = .05). RESULTS. Marginal gaps of crowns made by both methods showed equivalence in the buccal, mesial, and distal regions; however, in the lingual region, the GAID method produced higher marginal discrepancies (P > .001). Regarding internal gaps, no significant difference was observed between the two methods. Crowns produced by the GAID method exhibited larger occlusal discrepancies than those made by the CCAD method (P < .001). CONCLUSION. The fit accuracy of crowns fabricated using generative artificial intelligence was equivalent to those produced using the manual-input computer design method when the margins were well defined. While marginal and occlusal discrepancies were within clinically acceptable range, careful attention must be given to automated design outcomes, considering various tooth preparation shapes, anatomical structures, and clinical variations. [J Adv Prosthodont 2025;17:224-34]

관련 논문AI추천

Verification of the accuracy and design time of crowns designed with artificial intelligenceErika Inoue, Katsuhiko Kimoto, Kazuhide Seimiya, Koudai Nagata, Mihoko Atsumi, Noriyuki Hoshi, Shinji Kuroda, Toshifumi Nakashizu대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제1호Evaluation of the marginal and internal fit of interim crowns fabricated using AI-based dental CAD software김규리, 이규복, 손큰바다대한턱관절교합학회 · 구강회복응용과학지2025 · 제41권 제3호Comparison of marginal and internal fit of zirconia crowns fabricated by three-dimensional printing with different offset parameters: A preliminary pilot study김소연, 김욱태, 이규복, 이지민, 장경준, 손큰바다대한치과의사협회 · 대한치과의사협회지2025 · 제63권 제5호Effect of different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium crowns produced by computer-aided designing and selective laser melting processesChao-Yi Ma, Fa-Bing Tan, Hong-Wei Dai, Jin-Lin Song, Na Yu, Xue-Lu Tong대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호Marginal and internal fit of 3D printed provisional crowns according to build directions공현준, 김유리, 류지은, 장훈상, 정지혜대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Comparison of three-dimensional digital technique with twodimensional replica method for measuring marginal and internal fit of full coverage restorationsMahya Hasanzade, Marzieh Alikhasi, Naeime Moslemian, Soudabeh Koulivand대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호

이 간행물의 다른 논문 (5건)