본문 바로가기
KERD
논문KCI 등재

도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS)

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection

1

조회

0

다운로드

0

인용

0

참고문헌

초록

Abstract

In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

참고문헌 (11)

  1. A. J. Surowiec, "Dielectric properties of breast carcinoma and the surrounding tissues", 35, pp.257~263 (1988)
  2. J. Jossinet, "A review of parameters for the bioelectrical characterization of breast tissue", 873, pp.30~41 (1999)
  3. J. E. Silva, "Classification of breast tissue by electrical impedance spectroscopy", 38, pp.26~30 (2000)
  4. D. Holder, "Electrical Impedance Tomography: Methods, History and Applications" (2005), Bristol, UK, IOP Publishing
  5. M.Assenheimer, "The T-Scan technology: electrical impedance as a disgnostic tool for breast cancer detection", 22, pp.1~8 (2001)
  6. C. Perlet, "Electrical impedance measurement of the breast effect of hormonal changes associated with the menstrual cycle", 10, pp.1550~1554 (2000)
  7. H. Ammari, "T-Scan electrical impedance imaging system for anomaly detection" (2004), SIAM J. Appl.Math., in press
  8. J. K. Seo, "Mathematical framework and anomaly estimation algorithm for breast cancer det- ection: electrical impedance technique using TS2000 configuration", 51, pp.1898~1906 (2004)
  9. J. W. Lee, "Development of trans-admittance scanner (TAS) for breast cancer detection", 25, pp.335~342 (2004)
  10. T. I. Oh, "256-Channel Trans-Admittance Scanner with Lesion Estimation Algorithm for Breast Cancer Detection", 26, pp.207~214 (2005)
  11. S. Franco, "Design with Operational Amplifiers and Analog Integrated Circuits, 3rd. ed." (2002), McGraw-Hill, NY, USA