Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.
Abstract
Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.
참고문헌 (15)
- 윤대성, "Recent Research Trends in Nanoscale Electro-mechanical Systems for Bio-medical Applications", Biomedical Engineering Letters (BMEL), 1(1), pp.7~10 (2011), 대한의용생체공학회
- D'souza, S. F., "Microbial biosensors", Biosensors and Bioelectronics, 16, pp.337~353 (2001)
- Satake, D., "A sensor for blood cell counter using MEMS technology", Sensors and Actuators B, 83, pp.77~81 (2002)
- Shafiee, Hadi, "Selective isolation of live", dead cells using contactless dielectrophoresis(cDEP), 2010, pp.10, 438~445
- Pohl, Herbert A., "The motion and precipitation of suspensoids in divergent electric fields", Journal of Applied Physics, 22, pp.869~871 (1951)
- S.H. Baek, "Dielectrophoretic technique for measurement of chemical and biological interactions", Analytical Chemistry, 81, pp.7737~7742 (2009)
- Voldman, Joel., "Electrical forces for microscale cell manipulation", Annu. Rev. Biomed. Eng, 8, pp.425~454 (2006)
- S.W. Lee, "Dielectrophoretic tweezers for examining particle-surface interactions within microfluidic devices", Applied physics letters, 90, pp.223902~223902 (2007)
- Pethig, R., "Applications of dielectrophoresis in biotechnology", Trends in biotechnology, 15(10), pp.426~432 (1997)
- Chen, J., "Electrodeformation for single cell mechanical characterization", JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 21(5), pp.054012~ (2011)
- T.W. Lee, "Numerical and Experimental Study on Dielectrophoretic and Electrohydrodynamic Traps using Micro-Particles on an Interdigitated Electrode Array System", International Journal of Nonlinear Sciences and Numerical Simulation, 11(10), pp.777~784 (2010)
- Manaresi, N., "A CMOS chip for individual cell manipulation and detection", Solid-State Circuits, IEEE Journal of vol, 38(12), pp.2297~2305 (2003)
- 곽태준, "미세유체 칩 내에서 유전영동 집게(Dielectrophoretic Tweezers) 를 이용한 단백질A와 면역 글로불린 G의 결합에 관한 연구", 의공학회지, 34(3), pp.123~128 (2013), 대한의용생체공학회
- Markx, G. H., "DEP-FFF : Field-flow fractionation using non-uniform electric fields", Journal of liquid chromatography & related technologies, 20(16-17), pp.2857~2872 (1997)
- Huang, Y., "Introducing dielectrophoresis as a new force field for field-flow fractionation", Biophysical journal, 73(2), pp.1118~1129 (1997)