무구속적 방법으로 측정된 심전도의 신뢰도 판별
Quality Level Classification of ECG Measured using Non-Constraint Approach
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Recent technological advances in sensor fabrication and bio-signal processing enabled non-constraint and non-intrusive measurement of human bio-signals. Especially, non-constraint measurement of ECG makes it available to estimate various human health parameters such as heart rate. Additionally, non-constraint ECG measurement of wheelchair user provides real-time health parameter information for emergency response. For accurate emergency response with low false alarm rate, it is necessary to discriminate quality levels of ECG measured using non-constraint approach. Health parameters acquired from low quality ECG results in inaccurate information. Thus, in this study, a machine learning based approach for three-class classification of ECG quality level is suggested. Three sensors are embedded in the back seat, chest belt, and handle of automatic wheelchair. For the two sensors embedded in back seat and chest belt, capacitively coupled electrodes were used. The accuracy of quality level classification was estimated using Monte Carlo cross validation. The proposed approach demonstrated accuracy of 94.01%, 95.57%, and 96.94% for each channel of three sensors. Furthermore, the implemented algorithm enables classification of user posture by detection of contacted electrodes. The accuracy for posture estimation was 94.57%. The proposed algorithm will contribute to non-constraint and robust estimation of health parameter of wheelchair users.
Abstract
Recent technological advances in sensor fabrication and bio-signal processing enabled non-constraint and non-intrusive measurement of human bio-signals. Especially, non-constraint measurement of ECG makes it available to estimate various human health parameters such as heart rate. Additionally, non-constraint ECG measurement of wheelchair user provides real-time health parameter information for emergency response. For accurate emergency response with low false alarm rate, it is necessary to discriminate quality levels of ECG measured using non-constraint approach. Health parameters acquired from low quality ECG results in inaccurate information. Thus, in this study, a machine learning based approach for three-class classification of ECG quality level is suggested. Three sensors are embedded in the back seat, chest belt, and handle of automatic wheelchair. For the two sensors embedded in back seat and chest belt, capacitively coupled electrodes were used. The accuracy of quality level classification was estimated using Monte Carlo cross validation. The proposed approach demonstrated accuracy of 94.01%, 95.57%, and 96.94% for each channel of three sensors. Furthermore, the implemented algorithm enables classification of user posture by detection of contacted electrodes. The accuracy for posture estimation was 94.57%. The proposed algorithm will contribute to non-constraint and robust estimation of health parameter of wheelchair users.
참고문헌 (18)
- K. Kräuchi, "Circadian clues to sleep onset mechanisms", Neuropsychopharmacology, 25(S5), pp.S92~S96 (2001)
- S.Y. Sim, "Estimation of circadian body temperature rhythm based on heart rate in healthy, ambulatory subjects", IEEE J. Biomed. Health Inform
- Y. J. Kim, "Proposition of novel classification approach and features for improved realtime arrhythmia monitoring", Comput. Biol. Med, 75, pp.190~202 (2016)
- M. G. Tsipouras, "Automatic arrhythmia detection based on time and time-frequency analysis of heart rate variability", Comput. Methods Prog. Biomed, 74(2), pp.95~108 (2004)
- L. A. Geddes, "Pulse Transit Time as an Indicator of Arterial Blood Pressure", Psychophysiology, 18(1), pp.71~74 (1981)
- R. McCraty, "The effects of emotions on short-term power spectrum analysis of heart rate variability", Am. J. Cardiol, 76(14), pp.1089~1093 (1995)
- M. T. La Rovere, "Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarction", The Lancet, 351(9101), pp.478~484 (1998)
- 이원규, "침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘", 의공학회지, 35(4), pp.87~94 (2014), 대한의용생체공학회[DOI]
- 이정수, "패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극", 의공학회지, 35(6), pp.203~210 (2014), 대한의용생체공학회[DOI]
- J. S. Paul, "A Transform Domain SVD Filter for Suppression of Muscle Noise Artefacts in Exercise ECG’s", IEEE Trans. Biomed. Eng, 47(5), pp.654~663 (2000)
- J. L. Talmon, "Adaptive Gaussian Filtering in Routine ECG", VCG Analysis, 1986, pp.ASSP-34(3), 527~534
- N. V. Thakor, "Applications of Adaptive Filtering to ECG Analysis : Noise Cancellation and Arrhythmia Detection", IEEE Trans. Biomed. Eng, 38(8), pp.785~794 (1991)
- C. Vaz, "An Adaptive Estimation of Periodic Signals Using a Fourier Linear Combiner", IEEE Trans. Biomed. Eng, 42(1), pp.1~10 (1994)
- J. O. Wisbeck, "Application of Neural Networks to Separate Interferences and ECG Signals", Proceedings of IEEE international Caracas conference on devices, circuits and systems, pp.291~294 (1998)
- Q. Li, "A machine learning approach to multi-level ECG signal quality classification", Comput. Methods Programs Biomed, 117(3), pp.435~447 (2014)
- G. D. Clifford, "Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms", Physiol. Meas, 33(9), pp.1419~1433 (2012)
- J. Behar, "ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction", IEEE Trans. Biomed. Eng, 60(6), pp.1660~1666 (2013)
- Y. G. Lim, "Capacitive Measurement of ECG for Ubiquitous Healthcare", Ann. Biomed. Eng, 42(11), pp.2218~2227 (2014)
