본문 바로가기
KERD
논문KCI 등재

헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류공학일반

초록

Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

Abstract

Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

참고문헌 (9)

  1. T. R. F. Fulford-jones, "A portable, pow-power, wireless two-lead EKG system", 26th Annual International Conference of the IEEE EMBS, pp.2141~2144 (2004)
  2. H. Asada, "Wearable PPG-sensor", IEEE Eng Med Biol, 22(3), pp.28~40 (2003)
  3. H. J. Baek, "System for unconstrained ECG measurement on a toilet seat using capacitive coupled electrodes: the efficacy and practicality", Engineering in Medicine and Biology Society, pp.2326~2328 (2008)
  4. M. Koivuluoma, "EMFI as physiological signal sensor, first result in ProHe- Mon project", Proceedings of URSI XXVI convention on Radio Science and Second Finnish Wireless Communication Workshop (2004)
  5. E. M. Fong, "An indirect contact ECG monitoring with high value input impedance", International Conference on Electronics, Information and Communication, pp.504~505 (2012)
  6. T. Matsuda, "ECG monitoring of a car driver using capacitively-coupled electrodes", 30th Annual International Conference of the IEEE EMBS, pp.1315~1318 (2008)
  7. Y. S. Jeong, "Understanding of basic electrocardiogram", 4(1), pp.72~90 (2001), The Korean Society of Cardio-Vascular Interventional Technology
  8. 노윤홍, "일상생활 중 건강모니터링을 위한 착용형 심전도계측 시스템 개발", 센서학회지, 19(1), pp.43~51 (2010), 한국센서학회
  9. Y. G. Lim, "ECG measurement on a chair without conductive contact", IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 53(5), pp.956~959 (2006), IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC

관련 논문AI추천

이 간행물의 다른 논문 (11건)