A Wearable Electrocardiogram Monitoring System Robust to Motion Artifacts
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study proposes a wearable system that can measure electrocardiogram (ECG) signals reliably in an environment with high motion artifacts. This system employs a motion artifact extraction method based on a triple-axis accelerometer attached to each electrode independently to remove motion artifacts from ECG signals with high performance. Recursive Least Square (RLS) and Least Mean Square (LMS) algorithms remove extracted noise from the source signals, thereby obtaining a mean square error (MSE) of 0.0166 when using RLS and 0.0160 when using LMS. This means that the performance improved respectively by approximately 5.1% and 8.6% compared to that of the recently developed ECG monitoring system.
Abstract
This study proposes a wearable system that can measure electrocardiogram (ECG) signals reliably in an environment with high motion artifacts. This system employs a motion artifact extraction method based on a triple-axis accelerometer attached to each electrode independently to remove motion artifacts from ECG signals with high performance. Recursive Least Square (RLS) and Least Mean Square (LMS) algorithms remove extracted noise from the source signals, thereby obtaining a mean square error (MSE) of 0.0166 when using RLS and 0.0160 when using LMS. This means that the performance improved respectively by approximately 5.1% and 8.6% compared to that of the recently developed ECG monitoring system.
참고문헌 (14)
- N. V. Thakor, "Applications of adaptive filtering to ECG analysis : Noise cancellation and arrhythmia detection", IEEE Trans. Biomed. Eng., 38(8), pp.785~794 (1991)
- H. Kim, "Motion artifact removal using cascade adaptive filtering for ambulatory ECG monitoring system", Proc. IEEE Biomed. Circuits Syst. Conf, pp.160~163 (2012)
- W. Dargie, "A stochastic fusion technique for removing motion artefacts from the measurements of a wireless ECG", Proc. IEEE Int. Conf. Multisensor Fusion Integr. Intell. Syst, pp.449~454 (2016)
- P. Mithun, "A wavelet based technique for suppression of EMG noise and motion artifact in ambulatory ECG", Proc. IEEE Annu. Int. Conf. Eng. Med. Biol. Soc.,, pp.7087~7090 (2011)
- F. R. Hashim, "Wavelet based motion artifact removal for ECG signals", Proc. IEEE-EMBS Conf. Biomed. Eng. Sci.,, pp.339~342 (2012)
- F. Strasser, "Motion artifact removal in ECG signals using multi-resolution thresholding", Proc. 20th Eur. Signal Process. Conf, pp.899~903 (2012)
- S. Nagai, "Motion artefact removals for wearable ECG using stationary wavelet transform", Healthcare Technol. Lett., 4(4), pp.138~141 (2017)
- M. Milanesi, "Independent component analysis applied to the removal of motion artifacts from electrocardiographic signals", Med. Biol. Eng. Comput., 46(3), pp.251~261 (2008)
- C. Zou, "Motion artifact removal based on periodical property for ECG monitoring with wearable systems", Pervasive Mobile Computing., 40, pp.267~278 (2017)
- Xiang An, "Comparison of Motion Artifact Reduction Methods and the Implementation of Adaptive Motion Artifact Reduction in Wearable Electrocardiogram Monitoring", SENSORS (2020)
- Dilpreet Buxi, "Correlation Between ElectrodeTissue Impedance and Motion Artifact in Biopotential Recordings", IEEE SENSOR JOURNAL, 12(12) (2012)
- Mary Anne, "Adaptive Noise Cancelling of Motion Artifact in Stress ECG Signals Using Accelerometer", IEEE EMBS, 2002, 1756~1757
- Shing-Hong Liu, "Motion Artifact Reduction in Electrocardiogram Using Adaptive Filter", JMBE, 31(1), pp.67~72 (2010)
- Deepak Berwal, "Motion Artifact Removal in Ambulatory ECG Signal for Heart Rate Variability Analysis", IEEE SENSOR JOURNAL, 19(24) (2019)