침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘
Automatic Noise Removal and Peak Detection Algorithm for ECG Measured from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Recent technological advances have increased interest in personal health monitoring. Electrocardiogram(ECG) monitoring is a basic healthcare activity and can provide decisive information regarding cardiovascularsystem status. In this study, we developed a capacitive ECG measurement system that can be included within a clothmattress pad. The device permits ECG data to be obtained during sleep by using capacitive electrodes. However,it is difficult to detect R-wave peaks automatically because signals obtained from the system can include a high levelof noise from various sources. Because R-peak detection is important in ECG applications, we developed an algorithmthat can reduce noise and improve detection accuracy under noisy conditions. Algorithm reliability was evaluated bydetermining its sensitivity(Se), positive predictivity(+P), and error rate(Er) by using data from the MIT-BIH PolysomnographicDatabase and from our capacitive ECG system. The results showed that Se = 99.75%, +P = 99.77%,and Er = 0.47% for MIT-BIH Polysomnographic Database while Se = 96.47%, +P = 99.32%, and Er = 4.34% forour capacitive ECG system. Based on those results, we conclude that our R-peak detection method is capable of providinguseful ECG information, even under noisy signal conditions
Abstract
Recent technological advances have increased interest in personal health monitoring. Electrocardiogram(ECG) monitoring is a basic healthcare activity and can provide decisive information regarding cardiovascularsystem status. In this study, we developed a capacitive ECG measurement system that can be included within a clothmattress pad. The device permits ECG data to be obtained during sleep by using capacitive electrodes. However,it is difficult to detect R-wave peaks automatically because signals obtained from the system can include a high levelof noise from various sources. Because R-peak detection is important in ECG applications, we developed an algorithmthat can reduce noise and improve detection accuracy under noisy conditions. Algorithm reliability was evaluated bydetermining its sensitivity(Se), positive predictivity(+P), and error rate(Er) by using data from the MIT-BIH PolysomnographicDatabase and from our capacitive ECG system. The results showed that Se = 99.75%, +P = 99.77%,and Er = 0.47% for MIT-BIH Polysomnographic Database while Se = 96.47%, +P = 99.32%, and Er = 4.34% forour capacitive ECG system. Based on those results, we conclude that our R-peak detection method is capable of providinguseful ECG information, even under noisy signal conditions
참고문헌 (12)
- Analysis of International Competitiveness of the Korean Medical Tourism Industry and the Policy Implications, "M. G. Heo.", Korea Institute for Industrial Economics & Trade, 117~118 (2013)
- 이은미, "휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발", 의공학회지, 31(4), pp.316~320 (2010), 대한의용생체공학회
- A. R. Houghton., "Making sense of the ECG: a hands-on guide. 3rd ed", pp.1~7 (2008), Hodder Arnold
- 임용규, "Monitoring Physiological Signals Using Nonintrusive Sensors Installed in Daily Life Equipment", Biomedical Engineering Letters (BMEL), 1(1), pp.11~20 (2011), 대한의용생체공학회[DOI]
- M. S. Manikandan., "A novel method for detecting R-peaks in electrocardiogram(ECG)signal", Biomed. Signal Process. Control, 7(2), pp.118~128 (2012)
- Z. Zidelmal., "QRS detection using S-Transform and Shannon energy", Comput. Meth. Programs Biomed, 116(1), pp.1~9 (2014)
- 이진석, "Automatic Motion and Noise Artifact Detection in Holter ECG Data Using Empirical Mode Decomposition and Statistical Approaches", IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 59(6), pp.1499~1506 (2012), IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
- G. M. Friesen., "A Comparison of the Noise Sensitivity of Nine QRS Detection Algorithms", IEEE Trans. Biomed. Eng, 37(1), pp.85~98 (1990)
- V. X. Afonso., "ECG Beat Detection Using Filter Banks", IEEE Trans. Biomed. Eng, 46(2), pp.192~202 (1999)
- H. Zhu., "An R-peak detection method based on peaks of Shannon energy envelope", Biomed. Signal Pro-cess. Control, 8(5), pp.466~474 (2013)
- Z. Zidelmal., "QRS detection based on wavelet coefficients", Comput. Meth. Programs Biomed, 107(3), pp.490~496 (2012)
- M. Adnane., "Development of QRS detection algorithm designed for wearable cardiorespiratory system", Comput. Meth. Programs Biomed, 93(1), pp.20~31 (2009)
