Micro computed tomography (micro-CT) has been used for in vivo animal study owing to its noninvasive and high spatial resolution capability. However, the sizes of existing detectors for micro-CT systems are too small to obtain whole-body images of a small animal object with ~10 micron resolution and a part of its bones or other organs should be extracted. So, we have introduced the zoom-in micro-tomography technique which can obtain high-resolution images of a local region of an live animal object without extracting samples. In order to verify our zoom-in technique, we performed in vivo animal bone study. We prepared some SD (Sprague-Dawley) rats for making osteoporosis models. They were divided into control and ovariectomized groups. Again, the ovariectomized group is divided into two groups fed with normal food and with calcium-free food. And we took 3D tomographic images of their femurs with 20 micron resolution using our zoom-in tomography technique and observed the bone changes for 12 weeks. We selected ROI (region of interest) of a femur image and applied 2D FDT (fuzzy distance transform) to measure the trabecular bone thickness. The measured results showed obvious bone changes and big differences between control and ovariectomized groups. However, we found that the reliability of the measurement depended on the selection of ROI in a bone image for thickness calculation. So, we extended the method to 3D FDT technique. We selected 3D VOI (volume of interest) in the obtained 3D tomographic images and applied 3D FDT algorithm. The results showed that the 3D technique could give more accurate and reliable measurement.

Abstract

Micro computed tomography (micro-CT) has been used for in vivo animal study owing to its noninvasive and high spatial resolution capability. However, the sizes of existing detectors for micro-CT systems are too small to obtain whole-body images of a small animal object with ~10 micron resolution and a part of its bones or other organs should be extracted. So, we have introduced the zoom-in micro-tomography technique which can obtain high-resolution images of a local region of an live animal object without extracting samples. In order to verify our zoom-in technique, we performed in vivo animal bone study. We prepared some SD (Sprague-Dawley) rats for making osteoporosis models. They were divided into control and ovariectomized groups. Again, the ovariectomized group is divided into two groups fed with normal food and with calcium-free food. And we took 3D tomographic images of their femurs with 20 micron resolution using our zoom-in tomography technique and observed the bone changes for 12 weeks. We selected ROI (region of interest) of a femur image and applied 2D FDT (fuzzy distance transform) to measure the trabecular bone thickness. The measured results showed obvious bone changes and big differences between control and ovariectomized groups. However, we found that the reliability of the measurement depended on the selection of ROI in a bone image for thickness calculation. So, we extended the method to 3D FDT technique. We selected 3D VOI (volume of interest) in the obtained 3D tomographic images and applied 3D FDT algorithm. The results showed that the 3D technique could give more accurate and reliable measurement.

참고문헌 (18)

  1. "A new method for the model-independent assessment of thickness in three-dimensional images", 185(1), pp.67~75 (1997)
  2. "Stereological measures of trabecular bone structure comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies", 218, pp.171~2 179 (2005)
  3. "Three-dimensional methods for quantification of cancellous bone architecture", 20(4), pp.315~328 (1997)
  4. "The visualization and evaluation of bone architecture in the rat using three-dimensional X-ray microcomputed tomography", 17, pp.37~44 (1999)
  5. "A microtomographic system for the nondestructive evaluation of bone architecture" (1996)
  6. "three-dimensional microscopy of trabecular bone", 10, pp.264~270 (1995)
  7. "X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability", 49, pp.3889~3902 (2004)
  8. "standardization of nomenclature", 2 (1987)
  9. "The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone", 25(1), pp.55~60 (1999)
  10. "In vivo trabecular thickness measurement in cancellous bones:longitudinal rat imaging studies", 27, pp.695~702 (2006)
  11. "Trabecular thickness measurement in cancellous bones postmortem rat studies with the zoom-in micro-tomography technique", 26, pp.667~676 (2005)
  12. "A flat panel detector based micro-CT system:performance evaluation for small-animal imaging", 48, pp.4173~4185 (2003)
  13. "Practical cone-beam algorithm", 1, pp.6612~619 (1984)
  14. "Measurement of trabecular bone thickness in the limited resolution region of in vivo MRI by fuzzy distance transform", 23, pp.53~62 (2004)
  15. "Wehrli"Fuzzy distance transform : theory, algorithms, and applications" Comput. Vis.", 88, pp.171~190 (2002)
  16. "The Euclidean distance transform in arbitrary dimensions", 14, pp.883~888 (1993)
  17. "A fully parallel 3D thinning algorithm and its applications", 64(3), pp.420~433 (1996)
  18. "Marching cube algorithm:review and trilinear interpolation adaptation for image-based dosimetric modes", 27, pp.411~435 (2003)

관련 논문AI추천

이 간행물의 다른 논문 (6건)