압축 센싱 기법을 이용한 MRI 위상 영상의 재구성
Reconstruction of Magnetic Resonance Phase Images using the Compressed Sensing Technique
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Compressed sensing can be used to reduce scan time or to enhance spatial resolution in MRI. It is now recognized that compressed sensing works well in reconstructing magnitude images if the sampling mask and the sparsifying transform are well chosen. Phase images also play important roles in MRI particularly in chemical shift imaging and magnetic resonance electrical impedance tomography (MREIT). We reconstruct MRI phase images using the compressed sensing technique. Through computer simulation and real MRI experiments, we reconstructed phase images using the compressed sensing technique and we compared them with the ones reconstructed by conventional Fourier reconstruction technique. As compared to conventional Fourier reconstruction with the same number of phase encoding steps, compressed sensing shows better performance in terms of mean squared phase error and edge preservation. We expect compressed sensing can be used to reduce the scan time or to enhance spatial resolution of MREIT.
Abstract
Compressed sensing can be used to reduce scan time or to enhance spatial resolution in MRI. It is now recognized that compressed sensing works well in reconstructing magnitude images if the sampling mask and the sparsifying transform are well chosen. Phase images also play important roles in MRI particularly in chemical shift imaging and magnetic resonance electrical impedance tomography (MREIT). We reconstruct MRI phase images using the compressed sensing technique. Through computer simulation and real MRI experiments, we reconstructed phase images using the compressed sensing technique and we compared them with the ones reconstructed by conventional Fourier reconstruction technique. As compared to conventional Fourier reconstruction with the same number of phase encoding steps, compressed sensing shows better performance in terms of mean squared phase error and edge preservation. We expect compressed sensing can be used to reduce the scan time or to enhance spatial resolution of MREIT.
참고문헌 (11)
- M.Lustig, "Sparse MRI:The application of compressed sensing for rapid MR imaging", Magn.Reson.Med., 58, pp.1182~1195 (2007)
- D.Donoho, "Stable recovery of sparse overcomplete representation in the presence of noise", IEEE Trans.Inf.Theory, 52, pp.6~18 (2006)
- D.Donoho, "Compressed sensing", IEEE Trans.Inf.Theory, 52, pp.1289~1306 (2006)
- J.C.Ye, "Projection reconstruction MR imaging using FOCUSS", Magn.Reson.Med., 57, pp.764~775 (2007)
- G.C.Scott, "Measurement of nonuniform current density by magnetic resonance", IEEE Trans.Med.Imag., 10, pp.362~374 (1989)
- I.Sersa, "Electric current density imaging of mice tumors", Magn.Reson.Med., 37, pp.404~409 (1997)
- Suk Hoon Oh, "Magnetic Resonance Imaging of a Current Density Component", 의공학회지, 25(3), pp.3~3 (2004), 대한의용생체공학회
- O.Kwon, "Magnetic resonance electrical impedance tomography(MREIT):simulation study of J-substitution algorithm", IEEE Trans.Biomed.Eng, 49, pp.160~167 (2002)
- S.H.Oh, "Magnetic resonance electrical impedance tomography at 3 Tesla field strength", Mag.Reson.Med., 51, pp.1292~1296 (2004)
- Atul S. Minhas, "Chemical Shift Artifact Correction in MREIT", 의공학회지, 30(6), pp.461~468 (2009), 대한의용생체공학회
- Hyung Joong Kim, "MREIT Conductivity Imaging of Pneumonic Canine Lungs: Preliminary Post-mortem Study", 의공학회지, 31(2), pp.94~98 (2010), 대한의용생체공학회