본문 바로가기
KERD
논문KCI 등재

High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose : Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. Materials and Methods : In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. Results : The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. Conclusion : From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography.

Abstract

Purpose : Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. Materials and Methods : In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. Results : The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. Conclusion : From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography.

참고문헌 (19)

  1. B. Urban, "Three-dimensional Volume-rendered CT Angiography of the Renal Arteries and Veins: Normal Anatomy, Variants, and Clinical Application 1", Radiographics, 21(2), pp.373~386 (2001)
  2. P. Zanzonico, "Radiation Exposure of Computed Tomography and Direct Intracoronary Angiography Risk has its Reward", Journal of the American College of Cardiology, 47(9), pp.1846~1849 (2006)
  3. V. S. Lee, "Cardiovascular MRI: Physical principles to practical protocols" (2006), Lippincott Williams & Wilkins
  4. K. P. Pruessmann, "SENSE: Sensitivity encoding for fast MRI", Magn. Reson. Med,, 42(5), pp.952~962 (1999)
  5. D. K. Sodickwon, "Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays", Magn. Reson. Med,, 38(4), pp.591~603 (1997)
  6. M. A. Griswold, "eralized autocalibrating partially parallel acquisitions (GRAPPA)", Magn. Reson. Med, 47(6), pp.1202~1210 (2002)
  7. D. Sodickson, "Contrast-enhanced 3D MR Angiography with Simultaneous Acquisition of Spatial Harmonics: A Pilot Study 1", Radiology, 217(1), pp.284~289 (2000)
  8. G. Wilson, "Parallel Imaging in MR Angiography", Topics in Magnetic Resonance Imaging, 15(3), pp.169~185 (2004)
  9. M. Lustig, "Sparse MRI: The application of compressed sensing for rapid MR imaging", Magn. Reson. Med, 58(6), pp.1182~1195 (2007)
  10. D. L. Donoho, "Compressed sensing", IEEE Trans. on Information Theory, 52(5), pp.1289~1306 (2006)
  11. H. Jung, "Improved k-t BLAST and k-t SENSE using FOCUSS", Physics in Medicine and Biology, 52(11), pp.3201~3226 (2007)
  12. H. Jung, "k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI", Magn. Reson. Med,, 61, pp.103~116 (2009)
  13. S. Winkelmann, "An optimal radial profile order based on the Golden Ratio for time-resolved MRI", IEEE Transactions on Medical Imaging, 26(1), pp.68~76 (2007)
  14. H. V. Poor, "An Introduction of Signal Detection and Estimation" (1994), Springer-Verlag
  15. Z. Liang, "Spatiotemporal Imaging with Partially Separable Functions", in 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp.988~991 (2007)
  16. C. Mistretta, "Highly constrained backprojection for time-resolved MRI", Magn. Reson. Med, 55(1), pp.30~40 (2006)
  17. R. O’Halloran, "Iterative projection reconstruction of time-resolved images using highly-constrained back-proejction (HYPR)", Magn. Reson. Med, 59(1), pp.132~139 (2008)
  18. J. Wild, "Dynamic radial projection MRI of inhaled hyperpolarized 3 He gas", Magn. Reson. Med, 49(6), pp.991~997 (2003)
  19. Z. P. Liang, "Principles of magnetic resonance imaging: A signal processing perspectiv" (2000), IEEE press

관련 논문AI추천

이 간행물의 다른 논문 (9건)