초록

Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

Abstract

Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

참고문헌 (26)

  1. N. Zhang, "Zhang,Electrical Impedance Tomography based on Current Density Imaging,Toronto", 석사, pp.1992
  2. E.J. Woo, "Impedance tomography using internal current density distribution measured by nuclear magnetic resonance", SPIE, 2299, pp.377~385 (1994)
  3. O. Birgul, "Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography", Proc. IXth Int. Conf. Elec. Bio-Impedance Heidelberg Germany, pp.418~419 (1995)
  4. E.J. Woo, "Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging", Physiol. Meas, 29, pp.R1~R26 (2008)
  5. G.C. Scott, "Measurement of nonuniform current density by magnetic resonance", IEEE Trans. Med. Imag, 10, pp.362~374 (1991)
  6. E.M. Haacke, "Magnetic Resonance Imaging: Physical Principles and Sequence Design" (1999), John Wiley and Sons Inc
  7. W. H. Dixon, "Simple proton spectroscopic imaging", Radiology, 153, pp.189~194 (1984)
  8. J. Ma, "Dixon techniques for water and fat imaging", Mag. Res. Med, 28, pp.543~558 (2008)
  9. B.D. Coombs, "Two-point Dixon technique for water-fat signal decomposition with inhomogeneity correction", Mag. Res. Med, 38, pp.884~889 (1997)
  10. C.C. Lodes, "Proton MR chemical shift imaging using double and triple phase contrast acquisition methods", J. Comp. Ass. Tomo, 13(5), pp.855~861 (1989)
  11. G. H. Glover, "Three-point Dixon technique for true water", fat decomposition with inhomogeneity correction, 1991, pp.18, 371~383
  12. P.A. Hardy, "Separation of fat and water in fast spin-echo MR imaging with the three-point Dixon technique", J. Mag. Reson. Imaging, 5, pp.181~185 (1995)
  13. Q.S. Xiang, "Water-fat imaging with direct phase encoding", J. Mag. Reson. Imaging, 7, pp.1002~1015 (1997)
  14. J. Ma, "Method of efficient fast spin-echo Dixon imaging", Mag. Res. Med, 48, pp.1021~1027 (2002)
  15. A.R. Pineda, "Cramaer-Rao bounds for three-point decomposition of water and fat", Mag. Res. Med, 54, pp.625~635 (2005)
  16. S.B. Reeder, "Multi-coil Dixon chemical species separation with an iterative least-squares estimation method", Mag. Res. Med, 51, pp.35~45 (2004)
  17. C. Park, "Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT", Physiol. Meas, 28, pp.117~127 (2007)
  18. H.J. Kim, "Conductivity imaging of canine brain using a 3 T MREIT system: postmortem experiments", Physiol. Meas, 28, pp.1341~1353 (2007)
  19. J.K. Seo, "Reconstruction of conductivity and current density images using only one component of magnetic field measurements", IEEE Trans. Biomed. Eng, 50, pp.1121~1124 (2003)
  20. S.H. Oh, "Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography", Phys. Med. Biol, 48, pp.3101~3116 (2003)
  21. J.K. Seo, "Local harmonic Bz algorithm with domain decomposition in MREIT: computer simulation study", IEEE Trans. Med. Imag, 27(12), pp.1754~1761 (2008)
  22. K. Jeon, "CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)", J. Biomed. Eng. Res (2009)
  23. G.C. Scott, "Sensitivity of magnetic-resonance current density imaging", J. Mag. Res, 97, pp.235~254 (1992)
  24. R. Sadleir, "Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths", Physiol. Meas, 26, pp.875~884 (2005)
  25. M.J. Hamamura, "Correction of chemical shift artifact in magnetic resonance electrical impedance tomography", Proc. Intl. Soc. Mag. Reson. Med. Conf, 통권 : 17, pp.18~24 (2009)
  26. A.S. Minhas, "Chemical shift artifact correction in MREIT using 3-point Dixon technique", Proc. 10th Conf. EIT, pp.16~19 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (11건)