본문 바로가기
KERD
논문KCI 등재

용량성 전극의 동잡음 측정 장치 연구

A Study on Measurement of Capacitive Electrode Motion Artifact

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

The indirect-contact bio-electric measurements using capacitive electrodes show large motion artifacts in comparison with conventional direct-contact measurements. It is necessary to measure the motion artifacts quantitatively, for the researches of reducing the motion artifacts. In this study, a device for quantitative measurement of motion artifacts was built. Using the device, an electrode was rubbed against some cloth(cotton) and the voltage variation of the electrode was measured as motion artifact in several environmental conditions(temperature and relative humidity). The measured waveforms agreed with that expected by the triboelectricity and the prior observations of the motion artifacts. Therefore, the results demonstrated the usability of the measurement system built in this study. The measurement system will be a great contribution to future research for reducing motion artifact.

Abstract

The indirect-contact bio-electric measurements using capacitive electrodes show large motion artifacts in comparison with conventional direct-contact measurements. It is necessary to measure the motion artifacts quantitatively, for the researches of reducing the motion artifacts. In this study, a device for quantitative measurement of motion artifacts was built. Using the device, an electrode was rubbed against some cloth(cotton) and the voltage variation of the electrode was measured as motion artifact in several environmental conditions(temperature and relative humidity). The measured waveforms agreed with that expected by the triboelectricity and the prior observations of the motion artifacts. Therefore, the results demonstrated the usability of the measurement system built in this study. The measurement system will be a great contribution to future research for reducing motion artifact.

참고문헌 (15)

  1. Y. G. Lim, "ECG measurement on a chair without conductive contact", Biomedical Engineering, IEEE Transactions, 53(5), pp.956~959 (2006)
  2. Y. G. Lim, "ECG recording on a bed during sleep without direct skin-contact", Biomedical Engineering, IEEE Transactions, 54(4), pp.718~725 (2007)
  3. R. Prance, "An ultra-low-noise electricalpotential probe for human-body scanning", Measurement Science and Technology, 11(3), pp.291~ (2000)
  4. J. M. Lee, "Evaluation of a Capacitively-Coupled, Non-Contact (through Clothing) Electrode or ECG Monitoring and Life Signs Detection for the Objective Force Warfighter", DTIC, ~ (2004)
  5. T. Wartzek, "Triboelectricity in capacitive biopotential measurements", Biomedical Engineering, IEEE Transactions on, 58(5), pp.1268~1277 (2011)
  6. J. Ottenbacher, "Reliable motion artifact detection for ECG monitoring systems with dry electrodes", pp.1695~1698
  7. B. Feddes, "Reducing motion artefacts of capacitive sensors", pp.1532~1532
  8. S. Beardsmore-Rust, "Quantitative measurement of tribo-electric charging phenomena of dielectric materials", pp.1~
  9. G. Peng, "Non-contact, capacitive biosensor electrodes for electrostatic charge reduction", pp.1~4
  10. G. Peng, "Non-contact ECG sensing employing gradiometer electrodes", Biomedical Engineering, IEEE Transactions, 60(1), pp.179~ (2013)
  11. B. Eilebrecht, "Motion Artifact Removal from Capacitive ECG Measurements by Means of Adaptive Filtering", 5th European Conference of the International Federation for Medical and Biological Engineering, IFMBE Proceedings, pp.902~905 (2012)
  12. J. Ottenbacher, "Motion artefacts in capacitively coupled ECG electrodes", pp.1059~1062
  13. A. Searle, "A direct comparison of wet, dry and insulating bioelectric recording electrodes", Physiological Measurement, 21(2), pp.271~ (2000)
  14. E. Spinelli, "A capacitive electrode with fast recovery feature", Physiological Measurement, 33(8), pp.1277~ (2012)
  15. N. Jonassen, "Electrostatics: Springer Science & Business Media" (2013)

관련 논문AI추천