본문 바로가기
KERD
논문KCI 등재

체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구

A Study of Sensing Locations for ECG Monitoring clothing based on the skin change rate

5

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류생활과학

초록

Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20’ with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

Abstract

Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20’ with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

참고문헌 (23)

  1. Catherwood, P. A., "ECG motion artefact reduction improvements of a chestbased wireless patient monitoring system", In Computing in Cardiology, pp.557~560 (2010), IEEE
  2. 조길수, "바이오 모니터링 스마트 의류와 E-textile 개발 현황", 한국의류산업학회지, 10(1), pp.1~10 (2008), 한국의류산업학회
  3. 조하경, "센서 기반형 스마트 의류의 디자인 개발을 위한 탐색적 연구", 감성과학, 9(2), pp.141~150 (2006), 한국감성과학회
  4. 조하경, "생체신호 측정을 위한 기능성 의류의 디자인 연구-심전도 센싱 의류를 중심으로-", 감성과학, 13(3), pp.467~474 (2010), 한국감성과학회
  5. "Development of the smart clothing" (2014)[URL]
  6. Fletcher, G. F., "Exercise standards for testing and training a statement for healthcare professionals from the American Heart Association", Circulation, 104(14), pp.1694~1740 (2001)
  7. Griffiths, A., "A portable system for acquiring and removing motion artefact from ECG signals", In Journal of Physics: Conference Series, 76(1) (2007), IOP Publishing
  8. 한설아, "3차원 인체형상과 3차원 동작분석에 의한 방화복 소매패턴 개발", 한국의류산업학회지, 14(1), pp.109~121 (2012), 한국의류산업학회[DOI]
  9. Jang, S. E., "Effect of fabric elasticity and body movement on performance of electrocardiogram signal monitoring clothing", master, pp.2006
  10. 정연희, "휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발", 한국의류학회지, 34(1), pp.112~125 (2010), 한국의류학회
  11. Kearney, K., "Quantification of motion artifact in ECG electrode design", In Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, pp.1533~1536 (2007), IEEE
  12. Kim, H. D., "Adaptable noise reduction of ECG signals for feature extraction", Lecture Notes in Computer Science, 3973, pp.586~591 (2006)
  13. Kishimoto, Y., "Detecting motion artifact ECG noise during sleeping by means of a tri-axis accelerometer", In Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, pp.2669~2672 (2007), IEEE
  14. Koo, S. M., "A study on the design of re-modularized smart clothing for ECG-sensing", master, pp.2008
  15. Lee, Y. J., "Analysis and comparison of textile electrical characteristics in several shapes for biopotential signals", CICS : Conference on Instrumentation and Control Systems'08, pp.371~372 (2008)
  16. Liu, S. H., "Motion artifact reduction in electrocardiogram using adaptive A portable system for acquiring and removing motion artefact from ECG signals filter", Journal of Medical and Biological Engineering, 31(1), pp.67~72 (2011)
  17. "Motion capture system" (2011)[URL]
  18. "by NTT DoCoMo" (2014)[URL]
  19. 박혜준, "3D 패턴을 이용한 노인용 u-헬스케어 의복의 심전도 측정 연구", 한국의류산업학회지, 10(5), pp.676~682 (2008), 한국의류산업학회
  20. 박선형, "인체의 사지 동작 분석에 기반한 압전 수확 의류의 탐색적 연구", 감성과학, 16(1), pp.85~94 (2013), 한국감성과학회
  21. Puurtinen, M., "Best electrode locations for a small bipolar ECG device: signal strength analysis of clinical data", Annals of biomedical engineering, 37(2), pp.331~336 (2009)
  22. Such, O., "Motion tolerance in wearable sensors-The challenge of motion artifact", In Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, pp.1542~1545 (2007), IEEE
  23. Yoon, S. W., "Adaptive motion artifacts reduction using 3-axis accelerometer in E-textile ECG measurement system", Journal of medical systems, 32(2), pp.101~106 (2008)

관련 논문AI추천