간접접촉 심전도 측정용 전극의 주파수 특성

Frequency Response of the electrode for Indirect-contact ECG

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

Abstract

The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

참고문헌 (11)

  1. Y. G. Lim, "ECG measurement on a chair without conductive contact", IEEE Trans Biomed Eng, 53, pp.956~959 (2006)
  2. Ko Keun kim, "A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair", 의공학회지, 27(3), pp.83~88 (2006), 대한의용생체공학회
  3. J. Kim, "Development of a nonintrusive blood pressure estimation system for computer users", Telemed J E Health, 13, pp.57~64 (2007)
  4. Y. G. Lim, "ECG recording on a bed during sleep without direct skin-contact", IEEE Trans Biomed Eng, 54, pp.718~725 (2007)
  5. K. K. Kim, "Effect of missing RR-interval data on heart rate variability analysis in the time domain", Physiol Meas, 28, pp.1485~1494 (2007)
  6. S.Boutros and A.A.Hanna, "Some Electrical Properties of Wood Pulp", J. of Polymer Science, 16, pp.1443~1448 (1978)
  7. E.H.Jones, "A Moisture Meter for Textile Materials", J. Sci. Instrum, 17, pp.55~62 (1940)
  8. A. Searle, "A direct comparison of wet,dry and insulating bioelectric recording electrodes", Physiol Meas, 21, pp.271~283 (2000)
  9. R. M. David, "Insulated electrocardiogram electrodes", Med Biol Eng, 10, pp.742~751 (1972)
  10. M. E. Griffith, "Improved capacitive electrocardiogram electrodes for burn applications", Med Biol Eng Comput, 17, pp.641~646 (1979)
  11. C. H. Lagow, "Anodic insulated tantalum oxide electrocardiograph electrodes", IEEE Trans Biomed Eng, 18, pp.162~164 (1971)

관련 논문AI추천

이 간행물의 다른 논문 (10건)