Coapresta 2000을 이용한 혈액응고검사의 평가
Evaluation of an Automated Coagulation Analyzer Coapresta 2000
4
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: The Coapresta 2000 (Sekisui Medical CO., LTD, Japan) is a fully automated random-access multiparameter hemostasis coagulation analyzer, which is equipped with a photo-optical clot detection unit and a cap-piercing system. It is able to perform clotting time assays as well as colorimetric assays (synthetic substrate method and latex turbidimetric method). In this study, we evaluated the analytical performance of the Coapresta 2000 for coagulation test items and compared with that of the ACL-TOP (Instrumentation Laboratory, Lexingtion, MA, USA) analyzer, which is currently used for routine coagulation test items in our hospital. Methods: The Coapresta 2000 was evaluated with respect to its technical characteristics in the determination of 8 routine coagulation test items:prothrombin time, activated partial thromboplastin time, fibrinogen, fibrin-degradation product (FDP) antithrombin III, D-dimer, factors VIII and IX. Analyse-it (Analyse-it Software Ltd, UK) and SigmaStat (Systat Software, Inc., USA) were used for statistical analysis between items on the Coapresta 2000 and the ACL-TOP analyzer. Results: The intra-assay and inter-assay coefficients of variation (CV) were below 5% for both groups of samples having values within the reference interval and outside the reference interval. Significant interference was observed with hemolytic and icteric samples. Carryover was not detected. The results obtained by Coapresta 2000 were well correlated with those obtained by the ACL-TOP analyzer (r2 in the range from 0.781 to 0.969). Conclusions: We concluded that Coapresta 2000 analyzer was well correlated with ACL-TOP analyzer for the routine coagulation test items tested.
Abstract
Background: The Coapresta 2000 (Sekisui Medical CO., LTD, Japan) is a fully automated random-access multiparameter hemostasis coagulation analyzer, which is equipped with a photo-optical clot detection unit and a cap-piercing system. It is able to perform clotting time assays as well as colorimetric assays (synthetic substrate method and latex turbidimetric method). In this study, we evaluated the analytical performance of the Coapresta 2000 for coagulation test items and compared with that of the ACL-TOP (Instrumentation Laboratory, Lexingtion, MA, USA) analyzer, which is currently used for routine coagulation test items in our hospital. Methods: The Coapresta 2000 was evaluated with respect to its technical characteristics in the determination of 8 routine coagulation test items:prothrombin time, activated partial thromboplastin time, fibrinogen, fibrin-degradation product (FDP) antithrombin III, D-dimer, factors VIII and IX. Analyse-it (Analyse-it Software Ltd, UK) and SigmaStat (Systat Software, Inc., USA) were used for statistical analysis between items on the Coapresta 2000 and the ACL-TOP analyzer. Results: The intra-assay and inter-assay coefficients of variation (CV) were below 5% for both groups of samples having values within the reference interval and outside the reference interval. Significant interference was observed with hemolytic and icteric samples. Carryover was not detected. The results obtained by Coapresta 2000 were well correlated with those obtained by the ACL-TOP analyzer (r2 in the range from 0.781 to 0.969). Conclusions: We concluded that Coapresta 2000 analyzer was well correlated with ACL-TOP analyzer for the routine coagulation test items tested.
참고문헌 (11)
- Walenga JM, "Automation and quality control in the coagulation laboratory", Clin Lab Med, 14, pp.709~728 (1994)
- Amiral J, "Application of enzyme immunoassays to coagulation testing", Clin Chem, 30, pp.1512~1516 (1984)
- Fischer F, "Evaluation of the automated coagulation analyzer Sysmex CA-7000", Thromb Res, 117, pp.721~729 (2006)
- Appert-Flory A, "Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP", Thromb Res, 120, pp.733~743 (2007)
- Kim YA, "Measurement of PT, aPTT, and fibrinogen by automatic coagulation analyzer, ACL9000", J Lab Med Qual Assur, 24, pp.201~207 (2002)
- Kim HS, "Measurement of PT, APTT, and fibrinogen by automatic coagulation analyzer, Sysmex CA-540", J Clin Pathol Qual Control, 23, pp.247~252 (2001)
- Lee YW, "Laboratory evaluation of automated coagulation analyzers sysmex CA-1500TM and CA-7000TM", J Clin Pathol Qual Control, 23, pp.253~258 (2001)
- Clinical and Laboratory Standards Institute, "One-stage prothrombin time (PT) test and activated partial thromboplastin time (APTT) test;approved guideline. CLSI Document H47-A2. Wayne" (2008), Clinical and Laboratory Standards Institute
- National Committee for Clinical Laboratory Standards, "Procedure for the determination of fibrinogen in plasma; approved guideline-second edition. NCCLS Document H30-A2" (2001), National Committee for Clinical Laboratory Standards
- Milos M, "Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer-HemosIL reagents", Int J Lab Hematol, 31, pp.26~35 (2009)
- Eschwege V, "Evaluation of the automated coagulation analyser ACL TOP (instrumentation laboratory)", Ann Biol Clin (Paris), 64, pp.259~264 (2006)