본문 바로가기
KERD
논문KCI 등재

Analysis of midpalatal miniscrew-assisted maxillary molar distalization patterns with simultaneous use of fixed appliances: A preliminary study

6

조회

0

다운로드

7

인용

0

참고문헌

키워드

주제분류치의학

초록

Skeletal anchorage-assisted upper molar distalization has become one of the standard treatment modalities for the correction of Class II malocclusion. The purpose of this study was to analyze maxillary molar movement patterns according to appliance design, with the simultaneous use of buccal fixed orthodontic appliances. The authors devised two distinct types of midpalatal miniscrew-assisted maxillary molar distalizers, a lingual arch type and a pendulum type. Fourteen patients treated with one of the two types of distalizers were enrolled in the study, and the patterns of tooth movement associated with each type were compared. Pre- and post-treatment lateral cephalograms were analyzed. The lingual arch type was associated with relatively bodily upper molar distalization, while the pendulum type was associated with distal tipping with intrusion of the upper molar. Clinicians should be aware of the expected tooth movement associated with each appliance design. Further well designed studies with larger sample sizes are required. [Korean J Orthod 2016;46(1):55-61]

Abstract

Skeletal anchorage-assisted upper molar distalization has become one of the standard treatment modalities for the correction of Class II malocclusion. The purpose of this study was to analyze maxillary molar movement patterns according to appliance design, with the simultaneous use of buccal fixed orthodontic appliances. The authors devised two distinct types of midpalatal miniscrew-assisted maxillary molar distalizers, a lingual arch type and a pendulum type. Fourteen patients treated with one of the two types of distalizers were enrolled in the study, and the patterns of tooth movement associated with each type were compared. Pre- and post-treatment lateral cephalograms were analyzed. The lingual arch type was associated with relatively bodily upper molar distalization, while the pendulum type was associated with distal tipping with intrusion of the upper molar. Clinicians should be aware of the expected tooth movement associated with each appliance design. Further well designed studies with larger sample sizes are required. [Korean J Orthod 2016;46(1):55-61]

참고문헌 (24)

  1. Bolla E, "Evaluation of maxillary molar distalization with the distal jet : a comparison with other contemporary methods", Angle Orthod, 72, pp.481~494 (2002)
  2. Ahmad Sharafeddin Burhan, "Combined treatment with headgear and the Frog appliance for maxillary molar distalization: a randomized controlled trial", 대한치과교정학회지, 43(2), pp.101~109 (2013), 대한치과교정학회
  3. Fuziy A, "Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance", Am J Orthod Dentofacial Orthop, 130, pp.502~510 (2006)
  4. Patel MP, "Comparative distalization effects of Jones jig and pendulum appliances", Am J Orthod Dentofacial Orthop, 135, pp.336~342 (2009)
  5. Sugawara J, "Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system", Am J Orthod Dentofacial Orthop, 129, pp.723~733 (2006)
  6. Nur M, "Effects of maxillary molar distalization with Zygoma-Gear Appliance", Angle Orthod, 82, pp.596~602 (2012)
  7. Sa'aed NL, "Skeletal and dental effects of molar distalization using a modified palatal anchorage plate in adolescents", Angle Orthod, 85, pp.657~664 (2015)
  8. Kang YG, "Control of maxillary dentition with 2 midpalatal orthodontic miniscrews", Am J Orthod Dentofacial Orthop, 140, pp.879~885 (2011)
  9. Oh Y, "Treatment effects of microimplant-aided sliding mechanics on distal retraction of posterior teeth", Am J Orthod Dentofacial Orthop, 139, pp.470~481 (2011)
  10. Venkateswaran S, "Skeletal anchorage using mini-implants in the maxillary tuberosity region", J Ind Orthod Soc, 47, pp.217~224 (2013)
  11. Cozzani M, "Comparison of maxillary molar distalization with an implant-supported distal jet and a traditional tooth-supported distal jet appliance", Int J Dent, 2014, pp.937059~ (2014)
  12. Kircelli BH, "Maxillary molar distalization with a bone-anchored pendulum appliance", Angle Orthod, 76, pp.650~659 (2006)
  13. Polat-Ozsoy O, "Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage", Am J Orthod Dentofacial Orthop, 133, pp.339.e9~339.e17 (2008)
  14. Kwon HY, "Asymmetric transverse control of maxillary dentition with two midpalatal orthodontic miniscrews", Angle Orthod, 85, pp.525~534 (2015)
  15. Hilgers JJ, "The pendulum appliance for Class II noncompliance therapy", J Clin Orthod, 26, pp.706~714 (1992)
  16. Cha BK, "Skeletal anchorage for orthopedic correction of growing Class III patients", Semin Orthod, 17, pp.124~137 (2011)
  17. Kang YG, "Stability of mini-screws invading the dental roots and their impact on the paradental tissues in beagles", Angle Orthod, 79, pp.248~255 (2009)
  18. Kim YH, "Midpalatal miniscrews for orthodontic anchorage: factors affecting clinical success", Am J Orthod Dentofacial Orthop, 137, pp.66~72 (2010)
  19. Park J, "Three-dimensional evaluation of interradicular spaces and cortical bone thickness for the placement and initial stability of microimplants in adults", Am J Orthod Dentofacial Orthop, 136, pp.314~315 (2009)
  20. Jungkil Lee, "Effectiveness of en-masse retraction using midpalatal miniscrews and a modified transpalatal arch: Treatment duration and dentoskeletal changes", 대한치과교정학회지, 44(2), pp.88~95 (2014), 대한치과교정학회
  21. Onçağ G, "Osseointegrated implants with pendulum springs for maxillary molar distalization : a cephalometric study", Am J Orthod Dentofacial Orthop, 131, pp.16~26 (2007)
  22. Bussick TJ, "Dentoalveolar and skeletal changes associated with the pendulum appliance", Am J Orthod Dentofacial Orthop, 117, pp.333~343 (2000)
  23. Byloff FK, "Distal molar movement using the pendulum appliance. Part 1: Clinical and radiological evaluation", Angle Orthod, 67, pp.249~260 (1997)
  24. Sar C, "Comparison of two implant-supported molar distalization systems", Angle Orthod, 83, pp.460~467 (2013)

관련 논문AI추천

Comparative evaluation of molar distalization therapy using pendulum and distal screw appliancesAlberto Caprioglio, Alessandra Cafagna, Mattia Fontana, Mauro Cozzani대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제4호Noncompliance screw supported maxillary molar distalization in a parallel mannerAli Altuğ Biçakçi, Fatih Ozan, Ruhi Nalçaci대한치과교정학회 · 대한치과교정학회지2010 · 제40권 제4호Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal archesAbbas Moghimbeigi, Ahmad Sajedi, Amirfarhang Miresmaeili, Nasrin Farhadian대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제5호Three-dimensional evaluation of tooth movement in Class II malocclusions treated without extraction by orthodontic mini-implant anchorageDler Ali, Hnd Mohammed, Kyung-Hwa Kang, Sang-Cheol Kim, Seung-Hwan Koo대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제5호Maxillary total arch distalization using midpalatal mini-implant: Case report송창복, 임성훈치의학연구원 · Oral Biology Research2017 · 제41권 제3호Preliminary three-dimensional analysis of tooth movement and arch dimension change of the maxillary dentition in Class II division 1 malocclusion treated with first premolar extraction: conventional anchorage vs. mini-implant anchorage김병호, 박헌묵, 백승학, 양일형대한치과교정학회 · 대한치과교정학회지2012 · 제42권 제6호

이 간행물의 다른 논문 (7건)