본문 바로가기
KERD
논문KCI 등재

Stability and Intra-Individual Variation of Urinary Malondialdehyde and 2-Naphthol

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Objectives : Malondialdehyde (MDA), a lipid peroxidation by-product, has been widely used as an indicator of oxidative stress. Urinary 2-naphthol, a urinary PAH metabolite, is used as a marker of ambient particulate exposure and is associated with lung cancer and chronic obstructive pulmonary disease. However, the stability and intra-individual variation associated with urinary MDA and 2-naphthol have not been thoroughly addressed. The objective of this study was to assess the stability and intraindividual variation associated with urinary MDA and 2- naphthol. Methods : Urine samples were collected from 10 healthy volunteers (mean age 34, range 27~42 years old). Each sample was divided into three aliquots and stored under three different conditions. The levels of urinary MDA and 2- naphthol were analyzed 1) just after sampling, 2) after storage at room temperature (21!) for 16 hours, and 3) after storage in a -20! freezer for 16 hours. In addition, an epidemiological study was conducted in 44 Chinese subjects over a period of 3 weeks. The urinary MDA and 2- naphthol were measured by HPLC three times. Results : There was no difference in the levels of urinary MDA and 2-naphthol between the triplicate measurements (n=10, p=0.84 and p=0.83, respectively). The intra-class correlation coefficients (ICC) for urinary MDA and 2- naphthol were 0.74 and 0.42, respectively. However, the levels of PM2.5 in the air were well correlated with the levels of both MDA and 2-naphthol in the epidemiological study. Conclusions : These results suggest that urinary MDA and 2-naphthol remain stable under variable storage conditions, even at room temperature for 16 hours, and indicate that these markers can be used in epidemiological studies involving various sample storage conditions. The intra-CC of urinary 2-naphthol and MDA were acceptable for application to epidemiological studies.

Abstract

Objectives : Malondialdehyde (MDA), a lipid peroxidation by-product, has been widely used as an indicator of oxidative stress. Urinary 2-naphthol, a urinary PAH metabolite, is used as a marker of ambient particulate exposure and is associated with lung cancer and chronic obstructive pulmonary disease. However, the stability and intra-individual variation associated with urinary MDA and 2-naphthol have not been thoroughly addressed. The objective of this study was to assess the stability and intraindividual variation associated with urinary MDA and 2- naphthol. Methods : Urine samples were collected from 10 healthy volunteers (mean age 34, range 27~42 years old). Each sample was divided into three aliquots and stored under three different conditions. The levels of urinary MDA and 2- naphthol were analyzed 1) just after sampling, 2) after storage at room temperature (21!) for 16 hours, and 3) after storage in a -20! freezer for 16 hours. In addition, an epidemiological study was conducted in 44 Chinese subjects over a period of 3 weeks. The urinary MDA and 2- naphthol were measured by HPLC three times. Results : There was no difference in the levels of urinary MDA and 2-naphthol between the triplicate measurements (n=10, p=0.84 and p=0.83, respectively). The intra-class correlation coefficients (ICC) for urinary MDA and 2- naphthol were 0.74 and 0.42, respectively. However, the levels of PM2.5 in the air were well correlated with the levels of both MDA and 2-naphthol in the epidemiological study. Conclusions : These results suggest that urinary MDA and 2-naphthol remain stable under variable storage conditions, even at room temperature for 16 hours, and indicate that these markers can be used in epidemiological studies involving various sample storage conditions. The intra-CC of urinary 2-naphthol and MDA were acceptable for application to epidemiological studies.

참고문헌 (30)

  1. Sram, R.J., "Molecular epidemiology studies on occupational and environmental exposure to mutagens and carcinogens, 1997- 1999", Environ Health Perspect, 108(1), pp.57~70 (2000)
  2. Pembrey, M., "Genetic epidemiology: Some special contributions of birth cohorts", Paediatr Perinat Epidemiol, 18(1), pp.3~7 (2004)
  3. Landi, M.T., "Sample collection, processing and storage", IARC Sci Publ, (142), pp.223~236 (1997)
  4. Kato, I., "Intra- and inter-individual variability in measurements of biomarkers for oxidative damage in vivo: Nutrition and Breast Health Study", Biomarkers, 11(2), pp.143~152 (2006)
  5. Rundle, A.G., "Design options for molecular epidemiology research within Figure 2. Levels of urinary malondialdehyde (A) and levels of urinary 2-naphthol (B) compared to air pollutant levels such as PM2.5 in Changchun, China, A Bcohort studies", Cancer Epidemiol Biomarkers Prev, 14(8), pp.1899~1907 (2005)
  6. Vineis, P., "Husgafvel-Pursiainen K. Air pollution and cancer: Biomarker studies in human populations", Carcinogenesis, 26(11), pp.1846~1855 (2005)
  7. Kang, D., "Design issues in crosssectional biomarkers studies: Urinary biomarkers of PAH exposure and oxidative stress", Mutat Res, 592(1-2), pp.138~146 (2005)
  8. Meeker, J.D., "Utility of urinary 1-naphthol and 2- naphthol levels to assess environmental carbaryl and naphthalene exposure in an epidemiology study", J Expo Sci Environ Epidemiol, 17(4), pp.314~320 (2007)
  9. Boojar, M.M., "Development and reduction of hypertension and oxidative stress among detergent industry workers", Arch Environ Health, 59(12), pp.700~710 (2004)
  10. Serdar, B., "Urinary biomarkers of exposure to jet fuel (JP-8)", Environ Health Perspect, 111(14), pp.1760~1764 (2003)
  11. Buratti, M., "Urinary hydroxylated metabolites of polycyclic aromatic hydrocarbons as biomarkers of exposure in asphalt workers", Biomarkers, 12(3), pp.221~239 (2007)
  12. Kato, M., "Urinary biomarkers in charcoal workers exposed to wood smoke in Bahia State, Brazil", Cancer Epidemiol Biomarkers Prev, 13(6), pp.1005~1012 (2004)
  13. 김정희, "Effects of Air Pollutants on Childhood Asthma", Yonsei Medical Journal, 46(2), pp.239~244 (2005), 연세대학교의과대학
  14. Klaunig, J.E., "The role of oxidative stress in carcinogenesis", Annu Rev Pharmacol Toxicol, 44, pp.239~267 (2004)
  15. Basu, A.K., "Unequivocal demonstration that malondialdehyde is a mutagen", Carcinogenesis, 4(3), pp.331~333
  16. Del Rio, D., "review of recent studies on malondialdehyde as toxic molecule and biological marker of oxidative stress", Nutr Metab Cardiovasc Dis, 15(4), pp.316~328 (2005)
  17. Zhou, H., "Urinary marker for oxidative stress in kidneys in cisplatin-induced acute renal failure in rats", Nephrol Dial Transplant, 21(3), pp.616~623 (2006)
  18. Orhan, H., "Evaluation of a multi-parameter biomarker set for oxidative damage in man: Increased urinary excretion of lipid, protein and DNA oxidation products after one hour of exercise", Free Radic Res, 38(12), pp.1269~1279 (2004)
  19. Grotto, D., "Rapid quantification of malondialdehyde in plasma by high performance liquid chromatographyvisible detection", J Pharm Biomed Anal, 43(2), pp.619~624 (2007)
  20. Pilz, J.g., "Measurement of free and bound malondialdehyde in plasma by high-performance liquid chromatography as the 2,4-dinitrophenylhydrazine derivative", J Chromatogr B Biomed Sci Appl, 742(2), pp.315~325 (2000)
  21. Kim, H., "Assay of 2-naphthol in human urine by high-performance liquid chromatography", J Chromatogr B Biomed Sci Appl, 734(2), pp.211~217 (1999)
  22. Hong, Y.C., "Genetic susceptibility of term pregnant women to oxidative damage", Toxicol Lett, 129(3), pp.255~262 (2002)
  23. Armstrong, B.K., "Principles of Exposure Measurement in Epidemiology" (1994), Oxford University Press
  24. Gika, H.G., "Within-day reproducibility of an HPLC-MS-Based method for metabonomic analysis: Application to human urine", J Proteome Res, 6(8), pp.3291~3303 (2007)
  25. Feldmann, J., "Sample preparation and storage can change arsenic speciation in human urine", Clin Chem, 45(11), pp.1998~1997 (1999)
  26. Dunn, W.B., "A GC-TOF-MS study of the stability of serum and urine metabolomes during the UK Biobank sample collection and preparation protocols", Int J Epidemiol, 37(1), pp.23~30 (2008)
  27. Wu, T., "Stability of measurements of biomarkers of oxidative stress in blood over 36 hours", Cancer Epidemiol Biomarkers Prev, 13(8), pp.1399~1402 (2004)
  28. Kang, J.W., "Correlation of urinary 1-hydroxypyrene and 2- naphthol with total suspended particulates in ambient air in municipal middle-school students in Korea", Arch Environ Health, 57(4), pp.377~382 (2002)
  29. Sirensen, M., "Linking exposure to environmental pollutants with biological effects", Mutat Res, 544(2-3), pp.255~271 (2003)
  30. Yilmaz, G., "Are preservatives necessary in 24-hour urine measurements?", Clin Biochem