Qualitative and quantitative evaluation of root injury risk potentially burdening insertion of miniscrew implants
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: Microscrew implants (MSIs) offer many advantages, but some complications are known to occur during their insertion. One of the most commonly reported complications is root injury. Our aim was to identify factors associated with root injury and to evaluate their qualitative and quantitative values. Methods: Thirty-five orthodontists placed MSIs (AbsoAnchorⓇ, Dentos Co. Ltd, Daegu, Korea) in the upper jaw of typodonts, labially between the second premolar and the first molar, in low and high vertical positions. Root contacts were counted, and distances between MSI apices and roots were measured. Fear level of the orthodontists was surveyed before and after the experiment. Wilcoxon’s test, chi-square test, and Mann-Whitney test were used for statistical analysis. Results: Overall root contact rate of MSI insertion was 23.57%. The root contact rate was significantly higher in MSIs inserted at 90o (45.71%) than at 30o (1.43%). The distance between the dental root and MSI also increased significantly in MSIs inserted at 30o. Mean fear level before MSI insertion (4.6) significantly decreased after insertion (3.2); the causative factors were risk of injury to dental root and maxillary sinus or mandibular canal. Conclusions: Root injury is relatively rare, and oblique angulation reduces the risk of root and MSI contact.
Abstract
Objective: Microscrew implants (MSIs) offer many advantages, but some complications are known to occur during their insertion. One of the most commonly reported complications is root injury. Our aim was to identify factors associated with root injury and to evaluate their qualitative and quantitative values. Methods: Thirty-five orthodontists placed MSIs (AbsoAnchorⓇ, Dentos Co. Ltd, Daegu, Korea) in the upper jaw of typodonts, labially between the second premolar and the first molar, in low and high vertical positions. Root contacts were counted, and distances between MSI apices and roots were measured. Fear level of the orthodontists was surveyed before and after the experiment. Wilcoxon’s test, chi-square test, and Mann-Whitney test were used for statistical analysis. Results: Overall root contact rate of MSI insertion was 23.57%. The root contact rate was significantly higher in MSIs inserted at 90o (45.71%) than at 30o (1.43%). The distance between the dental root and MSI also increased significantly in MSIs inserted at 30o. Mean fear level before MSI insertion (4.6) significantly decreased after insertion (3.2); the causative factors were risk of injury to dental root and maxillary sinus or mandibular canal. Conclusions: Root injury is relatively rare, and oblique angulation reduces the risk of root and MSI contact.
참고문헌 (24)
- Kanomi R, "Mini-implant for orthodontic anchorage", J Clin Orthod, 31, pp.763~767 (1997)
- Park HS, "The skeletal cortical anchorage using titanium microscrew implants", Korean J Orthod, 29, pp.699~706 (1999)
- Melsen B, "Miniscrew implants: The Aarhus anchorage system", Semin Orthod, 11, pp.24~31 (2005)
- Papadopoulos MA, "The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 103, pp.e6~15 (2007)
- Park HS, "Nonextraction treatment of an open bite with microscrew implant anchorage", Am J Orthod Dentofacial Orthop, 130, pp.391~402 (2006)
- Park HS, "Microscrew implant anchorage sliding mechanics", World J Orthod, 6, pp.265~274 (2005)
- Kravitz ND, "Risks and complications of orthodontic miniscrews", Am J Orthod Dentofacial Orthop, 131(4), pp.S43~51 (2007)
- Cho UH, "Root contact during drilling for microimplant placement. Affect of surgery site and operator expertise", Angle Orthod, 80, pp.130~136 (2010)
- Asscherickx K, "Root repair after injury from mini-screw", Clin Oral Implants Res, 16, pp.575~578 (2005)
- Lee YK, "Root and bone response to the proximity of a mini-implant under orthodontic loading", Angle Orthod, 80, pp.452~458 (2010)
- Schnelle MA, "A radiographic evaluation of the availability of bone for placement of miniscrews", Angle Orthod, 74, pp.832~837 (2004)
- Kuroda S, "Root proximity is a major factor for screw failure in orthodontic anchorage", Am J Orthod Dentofacial Orthop, 131(4), pp.S68~73 (2007)
- Hernández LC, "‘Bone map’ for a safe placement of miniscrews generated by computed tomography", Clin Oral Implants Res, 19, pp.576~581 (2008)
- Hu KS, "Relationships between dental roots and surrounding tissues for orthodontic miniscrew installation", Angle Orthod, 79, pp.37~45 (2009)
- Hembree M, "Effects of intentional damage of the roots and surrounding structures with miniscrew implants", Am J Orthod Dentofacial Orthop, 135(280), pp.e1~9 (2009)
- Brisceno CE, "Healing of the roots and surrounding structures after intentional damage with miniscrew implants", Am J Orthod Dentofacial Orthop, 135, pp.292~301 (2009)
- Renjen R, "Root and pulp response after intentional injury from miniscrew placement", Am J Orthod Dentofacial Orthop, 136, pp.708~714 (2009)
- Andreasen JO, "The effect of limited drying or removal of the periodontal ligament. Periodontal healing after replantation of mature permanent incisors in monkeys", Acta Odontol Scand, 39, pp.1~13 (1981)
- Kang YG, "Stability of mini-screws invading the dental roots and their impact on the paradental tissues in beagles", Angle Orthod, 79, pp.248~255 (2009)
- Poggio PM, "“Safe zones”: a guide for miniscrew positioning in the maxillary and mandibular arch", Angle Orthod, 76, pp.191~197 (2006)
- Park HS, "Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion", J Clin Orthod, 35, pp.417~422 (2001)
- Park HS, "Factors affecting the clinical success of screw implants used as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 130, pp.18~25 (2006)
- Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
- Antoszewska J, "Five-year experience withorthodontic miniscrew implants: a retrospective investigation of factors influencing success rates", Am J Orthod Dentofacial Orthop, 136(158), pp.e1~10 (2009)