본문 바로가기
KERD
논문KCI 등재

Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data. Methods: Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners. Results: The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 µm, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners. Conclusions: The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.

Abstract

Objective: To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data. Methods: Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners. Results: The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 µm, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners. Conclusions: The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.

참고문헌 (19)

  1. Güth JF, "Accuracy of digital models obtained by direct and indirect data capturing", Clin Oral Investig, 17, pp.1201~1208 (2013)
  2. Boeddinghaus M, "Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients", Clin Oral Investig, 19, pp.2027~2034 (2015)
  3. Berrendero S, "Influence of conventional and digital intraoral impressions on the fit of CAD", CAM-fabricated all-ceramic crowns, 2016, pp.20, 2403~2410
  4. Atieh MA, "Accuracy evaluation of intraoral optical impressions : a clinical study using a reference appliance", J Prosthet Dent, 118, pp.400~405 (2017)
  5. Ender A, "Influence of scanning strategies on the accuracy of digital intraoral scanning systems", Int J Comput Dent, 16, pp.11~21 (2013)
  6. Kuhr F, "A new method for assessing the accuracy of full arch impressions in patients", J Dent, 55, pp.68~74 (2016)
  7. 이예규, "Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition", The Journal of Advanced of Prosthodontics, 7(6), pp.460~467 (2015), 대한치과보철학회[DOI]
  8. Sousa MV, "Accuracy and reproducibility of 3-dimensional digital model measurements", Am J Orthod Dentofacial Orthop, 142, pp.269~273 (2012)
  9. Lee KM, "Comparison of two intraoral scanners based on three-dimensional surface analysis", Prog Orthod, 19, pp.6~ (2018)
  10. Li H, "Influence of object translucency on the scanning accuracy of a powderfree intraoral scanner : a laboratory study", J Prosthet Dent, 117, pp.93~101 (2017)
  11. Goracci C, "Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions : a systematic review of the clinical evidence", Eur J Orthod, 38, pp.422~428 (2016)
  12. Ender A, "In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions", J Prosthet Dent, 115, pp.313~320 (2016)
  13. Flügge TV, "Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner", Am J Orthod Dentofacial Orthop, 144, pp.471~478 (2013)
  14. Grünheid T, "Clinical use of a direct chairside oral scanner : an assessment of accuracy, time, and patient acceptance", Am J Orthod Dentofacial Orthop, 146, pp.673~682 (2014)
  15. Ender A, "Accuracy of complete-arch dental impressions : a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)
  16. Nedelcu R, "Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions : a novel in vivo analysis method", J Dent, 69, pp.110~118 (2018)
  17. Müller P, "Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner", Quintessence Int, 47, pp.343~349 (2016)
  18. Oh KC, "Effects of scanning strategy and scanner type on the accuracy of intraoral scans : a new approach for assessing the accuracy of scanned data", J Prosthodont, 29, pp.518~523 (2020)
  19. Revilla-León M, "Intraoral digital scans-part 1 : influence of ambient scanning light conditions on the accuracy(trueness and precision)of different intraoral scanners", J Prosthet Dent, 124, pp.372~378 (2020)

관련 논문AI추천

이 간행물의 다른 논문 (7건)