In this paper, cycle performance analysis of cascade refrigeration system using natural refrigerants R744 for low temperature cycle, and R290, R600, R600a, R717 for high temperature cycle are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and condensing and evaporating temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. The COP of cascade refrigeration system using natural refrigerants is similar to the COP using freon refrigerant (R23 / R22). Points to be considered are th security, the attached facilities for natural refrigerants than COP.
Abstract
In this paper, cycle performance analysis of cascade refrigeration system using natural refrigerants R744 for low temperature cycle, and R290, R600, R600a, R717 for high temperature cycle are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and condensing and evaporating temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. The COP of cascade refrigeration system using natural refrigerants is similar to the COP using freon refrigerant (R23 / R22). Points to be considered are th security, the attached facilities for natural refrigerants than COP.
참고문헌 (12)
- Bodinus, W. S, "The rise and fall of carbon dioxide systems", pp.29~34 (1999), ASHRAE
- Donaldson, B, "Heat and cold: mastering the great indoors" (1994), ASHRAE
- Ebner, T, "Testing the Aviable Alternative - An Examination of R-134a, R-152a and R-290", IEA HPC Newsletter, 12(1) (1994)
- Liao, S, "Optimal heat rejection pressure in transcritical carbon dioxide air conditioning and heat pump system", IIF-IIR-Sections B and E-Oslo, 301~310 (1998)
- Neksa, P, "CO2 heat pump water heater: characteristics, system design and experimental results", International Journal of refrigeration, 12(3), pp.172~179 (1998)
- Hwang, Y, "Experimental Investigation of the CO2 Refrigeration cycle", pp.1219~1227 (1999)
- Brown,S.J, "Comparative analysis of an auto motive air conditioning systems operating with CO2 and R134a", International Journal of refrigeration, 25, pp.19~32 (2002)
- Park, S. N, "Performance of autocascade refrigeration system using carbon dioxide and R134a", Korea J. of Air-Conditioning and Refrigeration Eng, 11(6), pp.880~890 (1999)
- Chaichana, "Natural working fluids for solar-boosted heat pumps", Int. J. Refrigeration, 26, pp.637~643 (2003)
- Lee, T. S, "Thermodynamic analysis of optimal condensing temperature of cascade condenser in CO2", NH3 cascade refrigeration systems, 2006, pp.29, 1100~1108
- Bhattacharyya, S, "Optimization of a CO2–C3H8 cascade system for refrigeration and heating", Int. J. Refrigeration, 28, pp.1284~1292 (2005)
- Bansal,P.K, "Cascade systems: past, present, and future", Engineering Equation Solver, 113(1), pp.245~252 (2006), fChart Software Inc.