Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system
Abstract
To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system
참고문헌 (16)
- 하휘운, "Optimal design of passive containment cooling system for innovative PWR", Nuclear Engineering and Technology, 49(5), pp.941~952 (2017), 한국원자력학회
- S. Kim, "An experimental study on the validation of cooling capability for the Passive Auxiliary Feedwater System (PAFS) condensation heat exchanger", Nuclear Engineering and Design, 260, pp.54~63 (2013)
- B. U. Bae, "Integral effect test and code analysis on the cooling performance of the PAFS (passive auxiliary feedwater system) during an FLB (feedwater line break) accident", Nuclear Engineering and Design, 275, pp.249~263 (2014)
- S. Kim, "Experimental validation of cooling performance for the passive auxiliary feedwater system", Korea Society of Fluid Machinery Summer Meeting (2022)
- B. U. Bae, "Experimental investigation on condensation heat transfer for bundle tube heat exchanger of the PCCS (Passive Containment Cooling System)", Annals of Nuclear Energy, 139, pp.107285~ (2020)
- 이상원, "The concept of the innovative power reactor", Nuclear Engineering and Technology, 49(7), pp.1431~1441 (2017), 한국원자력학회
- W. P. Baek, "KAERI integral effect test program and ATLAS design", Nuclear Technology, 152, pp.183~ (2005)
- M. Ishii, "The three-level scaling approach with application to the purdue university multi-dimensional integral test assembly(PUMA)", Nuclear Engineering and Design, 186, pp.177~211 (1998)
- 배병언, "Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility", Nuclear Engineering and Technology, 53(8), pp.2477~2487 (2021), 한국원자력학회[DOI]
- Description Report of ATLAS Facility and Instrumentation (Third Revision), "J. B. Lee", Korea Atomic Energy Research Institute, ~, pp.KAERI (2020), TR-8106[DOI]
- 박현식, "APR1400 모의를 위한 ATLAS 안전주입탱크의 주입 성능에 관한 특성 시험", 에너지공학, 17(2), pp.67~76 (2008), 한국에너지학회
- K. Y. Choi, "Recent achievement and future prospects of the ATLAS program", Nuclear Engineering and Design, 354, pp.110168~ (2019)
- S. Cho, "Experiment on passive emergency core cooling system using ATLAS test facility", The 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19) (2022)
- Test Report on the OECD-ATLAS3 C2.2 Test : Intermediate Break Loss-of-Coolant-Accident (IBLOCA) Test with Passive Emergency Core Cooling System (PECCS) in ATLAS Facility, "B. U. Bae", OECD, ~, pp.ATLAS3-TR-22-01 (2022)
- Decay Energy release rates following shutdown of uranium fueled thermal reactors, "American Nuclear Society", ~, pp.Draft ANS-5.1 (1973), N18.5
- Final Report - Conceptual Design of Innovative Safe PWR, "Korea Hydro & Nuclear Power Co", ~, pp.2019-50003339-A16LP06 (2019)
