본문 바로가기
KERD
논문KCI 등재

Analysis on Optimal Approach of Blind Deconvolution Algorithm in Chest CT Imaging

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The main purpose of this work was to restore the blurry chest CT images by applying a blind deconvolution algorithm. In general, image restoration is the procedure of improving the degraded image to get the true or original image. In this regard, we focused on a blind deblurring approach with chest CT imaging by using digital image processing in MATLAB, which the blind deconvolution technique performed without any whole knowledge or information as to the fundamental point spread function (PSF). For our approach, we acquired 30 chest CT images from the public source and applied three type’s PSFs for finding the true image and the original PSF. The observed image might be convolved with an isotropic gaussian PSF or motion blurring PSF and the original image. The PSFs are assumed as a black box, hence restoring the image is called blind deconvolution. For the 30 iteration times, we analyzed diverse sizes of the PSF and tried to approximate the true PSF and the original image. For improving the ringing effect, we employed the weighted function by using the sobel filter. The results was compared with the three criteria including mean squared error (MSE), root mean squared error (RMSE) and peak signal-to-noise ratio (PSNR), which all values of the optimal-sized image outperformed those that the other reconstructed two-sized images. Therefore, we improved the blurring chest CT image by using the blind deconvolutin algorithm for optimal approach.

Abstract

The main purpose of this work was to restore the blurry chest CT images by applying a blind deconvolution algorithm. In general, image restoration is the procedure of improving the degraded image to get the true or original image. In this regard, we focused on a blind deblurring approach with chest CT imaging by using digital image processing in MATLAB, which the blind deconvolution technique performed without any whole knowledge or information as to the fundamental point spread function (PSF). For our approach, we acquired 30 chest CT images from the public source and applied three type’s PSFs for finding the true image and the original PSF. The observed image might be convolved with an isotropic gaussian PSF or motion blurring PSF and the original image. The PSFs are assumed as a black box, hence restoring the image is called blind deconvolution. For the 30 iteration times, we analyzed diverse sizes of the PSF and tried to approximate the true PSF and the original image. For improving the ringing effect, we employed the weighted function by using the sobel filter. The results was compared with the three criteria including mean squared error (MSE), root mean squared error (RMSE) and peak signal-to-noise ratio (PSNR), which all values of the optimal-sized image outperformed those that the other reconstructed two-sized images. Therefore, we improved the blurring chest CT image by using the blind deconvolutin algorithm for optimal approach.

참고문헌 (20)

  1. Fokkens WJ, "EPOS 2012: European position paper on rhinosinusitis and nasal polyps 2012. A Summary for Otorhinolaryngologists", Rhinology, 50(1), pp.1~12 (2012)
  2. 구현우, "CT Radiation Dose Optimization and Estimation: an Update for Radiologists", Korean Journal of Radiology, 13(1), pp.1~11 (2012), 대한영상의학회
  3. Gunn ML, "State of the art : Technologies for computed tomography dose reduction", Emergency Radiology, 17(3), pp.209~218 (2010)
  4. Kalra MK, "Strategies for CT radiation dose optimization", Radiology, 230(3), pp.619~628 (2004)
  5. McCollough CH, "CT dose reduction and dose management tools : Overview of available options", Radiographics, 26(2), pp.503~512 (2006)
  6. Beister M, "Iterative reconstruction methods in X-ray CT", Physica Medica, 28(2), pp.94~108 (2012)
  7. Fleischmann D, "Computed tomography-old ideas and new technology", European Radiology, 21(3), pp.510~517 (2011)
  8. Kalra MK, "Radiation dose reduction with sinogram affirmed iterative reconstruction technique for abdominal computed tomography", Journal of Computer Assisted Tomography, 36(3), pp.339~346 (2012)
  9. Leipsic J, "Iterative reconstruction for coronary CT angiography : Finding its way", The International Journal of Cardiovascular Imaging, 28(3), pp.613~620 (2012)
  10. NoWl PB, "Initial performance characterization of a clinical noise–suppressing reconstruction algorithm for mdct", American Journal of Roentgenology, 197(6), pp.1404~1409 (2011)
  11. Schuler CJ, "Learning to deblur", IEEE Transactions on Pattern Analysis and Machine Intelligence, 38(7), pp.1439~1451 (2015)
  12. Chakrabarti A, "A neural approach to blind motion deblurring", European Conference on Computer Vision (2016), Springer
  13. Sun J, "Learning a convolutional neural network for non-uniform motion blur removal", Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (2015)
  14. Kundur D, "Blind image deconvolution", IEEE Signal Processing Magazine, 13(3), pp.43~64 (1996)
  15. Kundur D, "Blind image deconvolution revisited", IEEE Signal Processing Magazine, 13(6), pp.61~63 (1996)
  16. 채금주, "Application of Deconvolution Algorithm of Point Spread Function in Improving Image Quality: An Observer Preference Study on Chest Radiography", Korean Journal of Radiology, 19(1), pp.147~152 (2018), 대한영상의학회[DOI]
  17. Kaushik P, "Detection of Noise in an Image using Blind Deconvolution Method", International Journal of Scientific Research and Management, 3, pp.3411~3415 (2020)
  18. Sharma K, "Restoration of Medical Images using Blind Image Deconvolution based on Ant Colony", International Journal of Computer Applications, 84, pp.24~27 (2013)
  19. 이영준, "Comparison of Based on Histogram Equalization Techniques by Using Normalization in Thoracic Computed Tomography", 방사선기술과학, 44(5), pp.473~480 (2021), 대한방사선과학회
  20. 민정환, "차트 각도를 이용한 해상력 특성 평가", 방사선기술과학, 44(4), pp.375~380 (2021), 대한방사선과학회

관련 논문AI추천

Newly-designed adaptive non-blind deconvolution with structural similarity index in single-photon emission computed tomography김규석, 이영진한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제12호노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화김이준, 박수빈, 박수연, 서강현, 오윤지, 이영진, 이우석, 정하선대한방사선과학회 · Journal of Radiological Science and Technology2024 · 제47권 제1호X-Ray Image Enhancement Using a Boundary Division Wiener Filter and Wavelet-Based Image Fusion ApproachAmjad Khan, Chai Soo See, Sajid Ullah Khan, Wang Yin Chai한국정보처리학회 · JIPS(Journal of Information Processing Systems)2016 · 제12권 제1호Comparison of Based on Histogram Equalization Techniques by Using Normalization in Thoracic Computed Tomography민정환, 이영준대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제5호Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters : A Pilot Study강성현, 김하진, 박보민, 서유진, 심지나, 이영진, 임세원대한방사선과학회 · Journal of Radiological Science and Technology2024 · 제47권 제3호Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법권오경, 진승오대한의용생체공학회 · 의공학회지2014 · 제35권 제5호

이 간행물의 다른 논문 (9건)