본문 바로가기
KERD
논문KCI 등재

Navigated versus Conventional Technique in High Tibial Osteotomy: A Meta­Analysis Focusing on Weight Bearing Effect

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: We aimed to determine whether navigated opening wedge high tibial osteotomy (HTO) is superior to the conventional technique in terms of accuracy of the coronal and sagittal alignment correction, functional outcome, and operative time. Methods: Studies comparing navigated and conventional HTO were included in this meta­analysis. We compared the incidence of radiological outliers in coronal alignment and tibial slope maintenance, mean differences in functional outcome scales, and operative time. Subgroup analyses were performed on coronal alignment accuracy based on the intraoperative method of alignment confirmation: fluoroscopy vs. gap measurement method.Results: Twelve studies were included: there were 434 knees in the navigated HTO studies and 405 knees in the conventional HTO studies. The risk of outlier was lower in navigated HTO than in conventional HTO; however, the difference was not significant when navigated HTO was compared with conventional HTO performed using the gap measurement method. Tibial slope maintenance was comparable or better in navigated HTO. No difference was found in the American Knee Society function and Lysholm scores. Navigated HTO necessitated a longer operative time of approximately 10 minutes.Conclusions: The use of navigation in HTO can improve accuracy in both coronal and sagittal alignments, but its clinical benefit is unclear.

Abstract

Purpose: We aimed to determine whether navigated opening wedge high tibial osteotomy (HTO) is superior to the conventional technique in terms of accuracy of the coronal and sagittal alignment correction, functional outcome, and operative time. Methods: Studies comparing navigated and conventional HTO were included in this meta­analysis. We compared the incidence of radiological outliers in coronal alignment and tibial slope maintenance, mean differences in functional outcome scales, and operative time. Subgroup analyses were performed on coronal alignment accuracy based on the intraoperative method of alignment confirmation: fluoroscopy vs. gap measurement method.Results: Twelve studies were included: there were 434 knees in the navigated HTO studies and 405 knees in the conventional HTO studies. The risk of outlier was lower in navigated HTO than in conventional HTO; however, the difference was not significant when navigated HTO was compared with conventional HTO performed using the gap measurement method. Tibial slope maintenance was comparable or better in navigated HTO. No difference was found in the American Knee Society function and Lysholm scores. Navigated HTO necessitated a longer operative time of approximately 10 minutes.Conclusions: The use of navigation in HTO can improve accuracy in both coronal and sagittal alignments, but its clinical benefit is unclear.

참고문헌 (39)

  1. Amendola A, "Results of high tibial osteotomy:review of the literature", Int Orthop, 34, pp.155~160 (2010)
  2. El-Azab HM, "Limb alignment after open-wedge high tibial osteotomy and its effect on the clinical outcome", Orthopedics, 34, pp.e622~e628 (2011)
  3. Dugdale TW, "Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length", Clin Orthop Relat Res, (274), pp.248~264 (1992)
  4. Hernigou P, "Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study", J Bone Joint Surg Am, 69, pp.332~354 (1987)
  5. Coventry MB, "Osteotomy about the knee for degenerative and rheumatoid arthritis", J Bone Joint Surg Am, 55, pp.23~48 (1973)
  6. Wang G, "Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy", Comput Aided Surg, 10, pp.73~85 (2005)
  7. Keppler P, "Computer aided high tibial open wedge osteotomy", Injury, 35(Suppl 1), pp.S-A68~S-A78 (2004)
  8. Hyun-Jung Kim, "Imageless Navigation Versus Conventional Open Wedge High Tibial Osteotomy: A Meta-Analysis of Comparative Studies", Knee Surgery and Related Research, 28(1), pp.16~26 (2016), 대한슬관절학회
  9. Van den Bempt M, "How accurately does high tibial osteotomy correct the mechanical axis of an arthritic varus knee? A systematic review", Knee, 23, pp.925~935 (2016)
  10. Yan J, "Outcome reporting following navigated high tibial osteotomy of the knee : a systematic review", Knee Surg Sports Traumatol Arthrosc, 24, pp.3529~3555 (2016)
  11. Lee DH, "The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy", Knee, 21, pp.451~455 (2014)
  12. Akamatsu Y, "Comparative study of opening-wedge high tibial osteotomy with and without a combined computed tomographybased and image-free navigation system", Arthroscopy, 32, pp.2072~2081 (2016)
  13. Akamatsu Y, "Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method", Knee Surg Sports Traumatol Arthrosc, 20, pp.586~593 (2012)
  14. Na YG, "The use of navigation in medial opening wedge high tibial osteotomy can improve tibial slope maintenance and reduce radiation exposure", Int Orthop, 40, pp.499~507 (2016)
  15. Schröter S, "Surgical accuracy in high tibial osteotomy : coronal equivalence of computer navigation and gap measurement", Knee Surg Sports Traumatol Arthrosc, 24, pp.3410~3417 (2016)
  16. Stanley JC, "Computer assisted alignment of opening wedge high tibial osteotomy provides limited improvement of radiographic outcomes compared to flouroscopic alignment", Knee, 23, pp.289~294 (2016)
  17. Iorio R, "Open-wedge high tibial osteotomy : comparison between manual and computerassisted techniques", Knee Surg Sports Traumatol Arthrosc, 21, pp.113~119 (2013)
  18. Kim SJ, "Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method : a 1-year retrospective, comparative study", Knee Surg Sports Traumatol Arthrosc, 17, pp.128~134 (2009)
  19. Reising K, "Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique", Knee Surg Sports Traumatol Arthrosc, 21, pp.181~188 (2013)
  20. Saragaglia D, "Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum", Orthopedics, 28(10 Suppl), pp.s1269~s1274 (2005)
  21. Jang KM, "Intraoperative fluoroscopic assessment of limb alignment is a reliable predictor for postoperative limb alignment in biplanar medial opening-wedge high tibial osteotomy", J Arthroplasty, 32, pp.756~760 (2017)
  22. Lee DH, "Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy", Arthroscopy, 28, pp.1842~1850 (2012)
  23. Specogna AV, "Radiographic measures of knee alignment in patients with varus gonarthrosis : effect of weightbearing status and associations with dynamic joint load", Am J Sports Med, 35, pp.65~70 (2007)
  24. Maurer F, "High tibial osteotomy: does navigation improve results?", Orthopedics, 29(10Suppl), pp.S130~S132 (2006)
  25. Beldame J, "Pin track induced fractures around computer-assisted TKA", Orthop Traumatol Surg Res, 96, pp.249~255 (2010)
  26. Brown MJ, "Low incidence of postoperative complications with navigated total knee arthroplasty", J Arthroplasty, 32, pp.2120~2126 (2017)
  27. Kamara E, "Pin site complications associated with computer-assisted navigation in hip and knee arthroplasty", J Arthroplasty, 32, pp.2842~2846 (2017)
  28. Higgins JPT, "Cochrane handbook for systematic reviews of interventions" (2011), Wiley-Blackwell
  29. "The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses"[URL]
  30. Sim JA, "Effect of weight-bearing on the alignment after open wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 18, pp.874~878 (2010)
  31. Ribeiro CH, "Opening wedge high tibial osteotomy : navigation system compared to the conventional technique in a controlled clinical study", Int Orthop, 38, pp.1627~1631 (2014)
  32. Brouwer RW, "The whole leg radiograph : standing versus supine for determining axial alignment", Acta Orthop Scand, 74, pp.565~568 (2003)
  33. Amis AA, "Biomechanics of high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 21, pp.197~205 (2013)
  34. Nha KW, "Change in posterior tibial slope after open-wedge and closed-wedge high tibial osteotomy : a meta-analysis", Am J Sports Med, 44, pp.3006~3013 (2016)
  35. 이동철, "High Tibial Osteotomy", Knee Surgery and Related Research, 24(2), pp.61~69 (2012), 대한슬관절학회[DOI]
  36. Brouwer RW, "Patellar height and the inclination of the tibial plateau after high tibial osteotomy. The open versus the closedwedge technique", J Bone Joint Surg Br, 87, pp.1227~1232 (2005)
  37. Rodner CM, "Medial opening wedge tibial osteotomy and the sagittal plane : the effect of increasing tibial slope on tibiofemoral contact pressure", Am J Sports Med, 34, pp.1431~1441 (2006)
  38. Giffin JR, "Effects of increasing tibial slope on the biomechanics of the knee", Am J Sports Med, 32, pp.376~382 (2004)
  39. Lee YS, "Serial assessment of weight-bearing lower extremity alignment radiographs after open-wedge high tibial osteotomy", Arthroscopy, 30, pp.319~325 (2014)

관련 논문AI추천

Imageless Navigation Versus Conventional Open Wedge High Tibial Osteotomy: A Meta-Analysis of Comparative Studies양재혁, Gi Won Choi, Hyun-Jung Kim, Jung-Ro Yoon대한슬관절학회 · Knee Surgery and Related Research2016 · 제28권 제1호Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy배대경, 송상준, 이종환, 조성진대한슬관절학회 · Knee Surgery and Related Research2017 · 제29권 제3호Surgical accuracy of coronal and sagittal alignment in conventional closed-wedge high tibial osteotomy after computer-assisted surgery experienceCheol Hee Park, Dae Kyung Bae, Sang Jun Song, Se Hwan Park대한슬관절학회 · Knee Surgery and Related Research2023 · 제35권 The influence of computer-assisted surgery experience on the accuracy and precision of the postoperative mechanical axis during computer-assisted lateral closingwedge high tibial osteotomyCheol Hee Park, Dae Kyung Bae, Hyun Woo Lee, Sang Jun Song대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제1호Disparity between Preoperative Target Correction Amount and Postoperative Correction Amount in Open Wedge High Tibial Osteotomy이용석, Eui Soo Lee, O-­Sung Lee대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제2호Is Bone Grafting Necessary in Opening Wedge High Tibial Osteotomy? A Meta-Analysis of Radiological Outcomes양재혁, Aldrich Raymund Fernandez, Hyung Jun Park, Hyun Jung Kim, Jae-Gwang Song, Jae-Hwi Han, Kyung-Wook Nha, Nikhl N Bhandare대한슬관절학회 · Knee Surgery and Related Research2015 · 제27권 제4호

이 간행물의 다른 논문 (8건)