Disparity between Preoperative Target Correction Amount and Postoperative Correction Amount in Open Wedge High Tibial Osteotomy
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to evaluate the disparity between the preoperative target correction amount and the postoperative correction amount in open wedge high tibial osteotomy (OWHTO) in patients divided according to the planned osteotomy gap.Materials and Methods: Seventytwo patients were divided into two groups (group 1 with the planned opening gap lager than the mean opening gap length of total patients and group 2 with a smaller opening gap). The opening gap was determined according to the target weight bearing line (WBL) ratio on the preoperative whole leg radiograph. Absolute and relative values of the disparity between the target and postoperative WBL ratios were compared between groups in order to clarify whether the disparity was deviated toward over or undercorrection.Results: The absolute value of disparity between the target and postoperative WBL ratios in group 1 was significantly larger than that in group 2 (6.01%±5.68% vs. 3.32%±3.38%; p=0.02). However, there was no statistically significant difference in relative values between groups (p=0.54). Conclusions: The postoperative WBL ratio after OWHTO was different from the preoperative target WBL ratio if the planned osteotomy gap was large. This mismatch was not deviated toward one side, either over or undercorrection.
Abstract
Purpose: The purpose of this study was to evaluate the disparity between the preoperative target correction amount and the postoperative correction amount in open wedge high tibial osteotomy (OWHTO) in patients divided according to the planned osteotomy gap.Materials and Methods: Seventytwo patients were divided into two groups (group 1 with the planned opening gap lager than the mean opening gap length of total patients and group 2 with a smaller opening gap). The opening gap was determined according to the target weight bearing line (WBL) ratio on the preoperative whole leg radiograph. Absolute and relative values of the disparity between the target and postoperative WBL ratios were compared between groups in order to clarify whether the disparity was deviated toward over or undercorrection.Results: The absolute value of disparity between the target and postoperative WBL ratios in group 1 was significantly larger than that in group 2 (6.01%±5.68% vs. 3.32%±3.38%; p=0.02). However, there was no statistically significant difference in relative values between groups (p=0.54). Conclusions: The postoperative WBL ratio after OWHTO was different from the preoperative target WBL ratio if the planned osteotomy gap was large. This mismatch was not deviated toward one side, either over or undercorrection.
참고문헌 (29)
- El-Azab H, "The effect of closed-and open-wedge high tibial osteotomy on tibial slope : a retrospective radiological review of 120 cases", J Bone Joint Surg Br, 90, pp.1193~1197 (2008)
- Staubli AE, "TomoFix:a new LCP-concept for open wedge osteotomy of the medial proximal tibia--early results in 92 cases", Injury, 34(Suppl 2), pp.B55~B62 (2003)
- Schröter S, "High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate(Position HTO plate)without bone substitute", Arthroscopy, 27, pp.644~652 (2011)
- 한승범, "Biomechanical Properties of a New Anatomical Locking Metal Block Plate for Opening Wedge High Tibial Osteotomy: Uniplane Osteotomy", Knee Surgery and Related Research, 26(3), pp.155~161 (2014), 대한슬관절학회
- Fan JC, "Open wedge high tibial osteotomy : cause of patellar descent", J Orthop Surg Res, 7, pp.3~ (2012)
- Lee YS, "Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs", Knee Surg Sports Traumatol Arthrosc, 21, pp.2542~2547 (2013)
- Hernigou P, "Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study", J Bone Joint Surg Am, 69, pp.332~354 (1987)
- Dugdale TW, "Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length", Clin Orthop Relat Res, (274), pp.248~264 (1992)
- Miniaci A, "Proximal tibial osteotomy. A new fixation device", Clin Orthop Relat Res, (246), pp.250~259 (1989)
- Schröter S, "Digital planning of high tibial osteotomy. Interrater reliability by using two different software", Knee Surg Sports Traumatol Arthrosc, 21, pp.189~196 (2013)
- Pape D, "Preoperative planning for high tibial osteotomies", Oper Tech Orthop, 17, pp.2~11 (2007)
- Amis AA, "Biomechanics of high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 21, pp.197~205 (2013)
- 배대경, "CAS를 이용한 개방형 경골 근위부 절골술에서 네비게이션 장치상 계측치와 방사선 학적 계측치의 비교", 대한정형외과학회지, 43(3), pp.301~307 (2008), 대한정형외과학회
- Hankemeier S, "Navigated open-wedge high tibial osteotomy : advantages and disadvantages compared to the conventional technique in a cadaver study", Knee Surg Sports Traumatol Arthrosc, 14, pp.917~921 (2006)
- Lee DH, "Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy", Arthroscopy, 28, pp.1842~1850 (2012)
- Schröter S, "Precision in the planning of open wedge HTO", Z Orthop Unfall, 150, pp.368~373 (2012)
- Akamatsu Y, "Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method", Knee Surg Sports Traumatol Arthrosc, 20, pp.586~593 (2012)
- Gebhard F, "Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy", Arch Orthop Trauma Surg, 131, pp.297~302 (2011)
- Agneskirchner JD, "The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee : a biomechanical study", Arthroscopy, 23, pp.852~861 (2007)
- Marti CB, "Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy", Arthroscopy, 20, pp.366~372 (2004)
- Seong-Dae Yoon, "Comparison of Cable Method and Miniaci Method Using Picture Archiving and Communication System in Preoperative Planning for Open Wedge High Tibial Osteotomy", Knee Surgery and Related Research, 28(4), pp.283~288 (2016), 대한슬관절학회
- Kim HJ, "Preoperative planning using the picture archiving and communication system technique in high tibial osteotomy", J Orthop Surg(Hong Kong), 25, pp.2309499016684701~ (2017)
- Kim HJ, "More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 26, pp.3452~3458 (2018)
- Lee YS, "Serial assessment of weight-bearing lower extremity alignment radiographs after open-wedge high tibial osteotomy", Arthroscopy, 30, pp.319~325 (2014)
- Lee YS, "Comparative analysis of osteotomy accuracy between the conventional and devised technique using a protective cutting system in medial open-wedge high tibial osteotomy", J Orthop Sci, 20, pp.129~136 (2015)
- Fujisawa Y, "The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints", Orthop Clin North Am, 10, pp.585~608 (1979)
- Jung WH, "Second-look arthroscopic assessment of cartilage regeneration after medial opening-wedge high tibial osteotomy", Arthroscopy, 30, pp.72~79 (2014)
- Marx RG, "Reliability of lower extremity alignment measurement using radiographs and PACS", Knee Surg Sports Traumatol Arthrosc, 19, pp.1693~1698 (2011)
- Hee-June Kim, "Evaluation of Accuracy of a Three-Dimensional Printed Model in Open-Wedge High Tibial Osteotomy", The Journal of Knee Surgery, 32(09), pp.841~846 (2019), Georg Thieme Verlag KG[DOI]
