Imageless Navigation Versus Conventional Open Wedge High Tibial Osteotomy: A Meta-Analysis of Comparative Studies
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
purpose: To summarize and compare radiological and clinical outcomes of open wedge high tibial osteotomy (HTO) using imageless computer-assisted navigation with conventional HTO.methods: A literature search of online register databases was conducted. The risk ratio (RR) of radiological outliers and mean differences in clinical outcomes were compared between navigated and conventional HTOs. Radiological results were evaluated by subgroup analyses according to the study period (concurrent/consecutive) and the use of locking fixation device.results: Seven comparative studies with a total sample size of 406 knees were included in this review. Radiographically, the mechanical axis [MA] was within the acceptable range (0°–6°) in 83.7% of the navigation HTO group, showing significant difference from 62.1% of the conventional HTO group. Clinically, despite the forest plot demonstrating a general trend of favoring the navigation system, there were not sufficient studies to determine statistical significance in the meta-analysis. None of the subgroup analyses demonstrated significant differences in the RR of MA outliers. conclusions: The present meta-analysis indicates that the use of navigation in open wedge HTO improves the precision of mechanical alignment by decreasing the incidence of outliers; however, the clinical benefit is not conclusive. Additionally, none of the subgroup analyses demonstrated significant difference in the RR of MA outliers.
Abstract
purpose: To summarize and compare radiological and clinical outcomes of open wedge high tibial osteotomy (HTO) using imageless computer-assisted navigation with conventional HTO.methods: A literature search of online register databases was conducted. The risk ratio (RR) of radiological outliers and mean differences in clinical outcomes were compared between navigated and conventional HTOs. Radiological results were evaluated by subgroup analyses according to the study period (concurrent/consecutive) and the use of locking fixation device.results: Seven comparative studies with a total sample size of 406 knees were included in this review. Radiographically, the mechanical axis [MA] was within the acceptable range (0°–6°) in 83.7% of the navigation HTO group, showing significant difference from 62.1% of the conventional HTO group. Clinically, despite the forest plot demonstrating a general trend of favoring the navigation system, there were not sufficient studies to determine statistical significance in the meta-analysis. None of the subgroup analyses demonstrated significant differences in the RR of MA outliers. conclusions: The present meta-analysis indicates that the use of navigation in open wedge HTO improves the precision of mechanical alignment by decreasing the incidence of outliers; however, the clinical benefit is not conclusive. Additionally, none of the subgroup analyses demonstrated significant difference in the RR of MA outliers.
참고문헌 (28)
- Coventry MB, "Osteotomy of the upper portion of the tibia for degenerative arthritis of the knee : a preliminary report", J Bone Joint Surg Am, 47, pp.984~990 (1965)
- Brouwer RW, "Osteotomy for treating knee osteoarthritis. Cochrane Database Syst Rev", 12, pp.CD004019~ (2014)
- Rampersaud YR, "Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation:a CT analysis", Spine (Phila Pa 1976), 30, pp.E183~E190 (2005)
- Stockle U, "Clinical applications:pelvis.", Injury, 35(Suppl 1), pp.A46~A56 (2004)
- Amiot LP, "Computed tomography-based navigation for hip, knee, and spine surgery", Clin Orthop Relat Res, (421), pp.77~86 (2004)
- Wang G, "Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy", Comput Aided Surg, 10, pp.73~85 (2005)
- Cheng T, "Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A metaanalysis of randomized controlled trials?", Knee Surg Sports Traumatol Arthrosc, 20, pp.1307~1322 (2012)
- Fu D, "Comparison of high tibial osteotomy and unicompartmental knee arthroplasty in the treatment of unicompartmental osteoarthritis : a meta-analysis", J Arthroplasty, 28, pp.759~765 (2013)
- Fu Y, "Alignment outcomes in navigated total knee arthroplasty : a meta-analysis", Knee Surg Sports Traumatol Arthrosc, 20, pp.1075~1082 (2012)
- Weber P, "Improved accuracy in computer-assisted unicondylar knee arthroplasty : a metaanalysis", Knee Surg Sports Traumatol Arthrosc, 21, pp.2453~2461 (2013)
- Bae DK, "Closed-wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique", J Bone Joint Surg Br, 91, pp.1164~1171 (2009)
- Higgins JP, "Measuring inconsistency in meta-analyses", BMJ, 327, pp.557~560 (2003)
- Akamatsu Y, "Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method", Knee Surg Sports Traumatol Arthrosc, 20, pp.586~593 (2012)
- Iorio R, "Open-wedge high tibial osteotomy : comparison between manual and computerassisted techniques", Knee Surg Sports Traumatol Arthrosc, 21, pp.113~119 (2013)
- Kim SJ, "Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method : a 1-year retrospective, comparative study", Knee Surg Sports Traumatol Arthrosc, 17, pp.128~134 (2009)
- Maurer F, "High tibial osteotomy: does navigation improve results?", Orthopedics, 29(10 Suppl), pp.S130~S132 (2006)
- Reising K, "Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique", Knee Surg Sports Traumatol Arthrosc, 21, pp.181~188 (2013)
- Ribeiro CH, "Opening wedge high tibial osteotomy : navigation system compared to the conventional technique in a controlled clinical study", Int Orthop, 38, pp.1627~1631 (2014)
- Saragaglia D, "Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum", Orthopedics, 28(10 Suppl), pp.s1269~s1274 (2005)
- "The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses" (2011)[URL]
- Hankemeier S, "Navigated open-wedge high tibial osteotomy : advantages and disadvantages compared to the conventional technique in a cadaver study", Knee Surg Sports Traumatol Arthrosc, 14, pp.917~921 (2006)
- Fujisawa Y, "The effect of high tibial osteotomy on osteoarthritis of the knee : an arthroscopic study of 54 knee joints", Orthop Clin North Am, 10, pp.585~608 (1979)
- Niemeyer P, "Two-year results of open-wedge high tibial osteotomy with fixation by medial plate fixator for medial compartment arthritis with varus malalignment of the knee", Arthroscopy, 24, pp.796~804 (2008)
- Niemeyer P, "Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment : 3-year results with regard to preoperative arthroscopic and radiographic findings", Arthroscopy, 26, pp.1607~1616 (2010)
- Miniaci A, "Proximal tibial osteotomy: a new fixation device. Clin Orthop Relat Res", Clin Orthop Relat Res, (246), pp.250~259 (1989)
- Dugdale TW, "Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length", Clin Orthop Relat Res, (274), pp.248~264 (1992)
- Coventry MB, "Osteotomy about the knee for degenerative and rheumatoid arthritis", J Bone Joint Surg Am, 55, pp.23~48 (1973)
- Insall JN, "High tibial osteotomy for varus gonarthrosis : a long-term follow-up study", J Bone Joint Surg Am, 66, pp.1040~1048 (1984)
