본문 바로가기
KERD
논문KCI 등재

Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: To compare navigation and weight bearing radiographic measurements of mechanical axis (MA) before and after closed wedge high tibial osteotomy (HTO) and to evaluate post­osteotomy changes in MA assessed during application of external varus or valgus force.Materials and Methods: Data from 30 consecutive patients (30 knees) who underwent computer­assisted closed­wedge HTO were prospectively analyzed. Pre­ and postoperative weight bearing radiographic evaluation of MA was performed. Under navigation guidance, pre­ and post­osteotomy MA values were measured in an unloaded position. Any change in the post­osteotomy MA in response to external varus or valgus force, which was named as dynamic range, was evaluated with the navigation system. The navigation and weight bearing radiographic measurements were compared. Results: Although there was a positive correlation between navigation and radiographic measurements, the reliability of navigation measurements of coronal alignment was reduced after osteotomy and wedge closing. The mean post­osteotomy MA value measured with the navigation was 3.5°±0.8° valgus in an unloaded position. It was 1.3°±0.8° valgus under varus force and 5.8°±1.1° valgus under valgus force. The average dynamic range was >±2°.Conclusions: Poten tial differences between the postoperative MAs assessed by weight bearing radiographs and the navigation system in unloaded position should be con sidered during computer­assisted closed wedge HTO. Care should be taken to keep the dynamic range within the permissible range of alignment goal in HTO.

Abstract

Purpose: To compare navigation and weight bearing radiographic measurements of mechanical axis (MA) before and after closed wedge high tibial osteotomy (HTO) and to evaluate post­osteotomy changes in MA assessed during application of external varus or valgus force.Materials and Methods: Data from 30 consecutive patients (30 knees) who underwent computer­assisted closed­wedge HTO were prospectively analyzed. Pre­ and postoperative weight bearing radiographic evaluation of MA was performed. Under navigation guidance, pre­ and post­osteotomy MA values were measured in an unloaded position. Any change in the post­osteotomy MA in response to external varus or valgus force, which was named as dynamic range, was evaluated with the navigation system. The navigation and weight bearing radiographic measurements were compared. Results: Although there was a positive correlation between navigation and radiographic measurements, the reliability of navigation measurements of coronal alignment was reduced after osteotomy and wedge closing. The mean post­osteotomy MA value measured with the navigation was 3.5°±0.8° valgus in an unloaded position. It was 1.3°±0.8° valgus under varus force and 5.8°±1.1° valgus under valgus force. The average dynamic range was >±2°.Conclusions: Poten tial differences between the postoperative MAs assessed by weight bearing radiographs and the navigation system in unloaded position should be con sidered during computer­assisted closed wedge HTO. Care should be taken to keep the dynamic range within the permissible range of alignment goal in HTO.

참고문헌 (22)

  1. Coventry MB, "Proximal tibial osteotomy : a critical long-term study of eighty-seven cases", J Bone Joint Surg Am, 75, pp.196~201 (1993)
  2. 이동철, "High Tibial Osteotomy", Knee Surgery and Related Research, 24(2), pp.61~69 (2012), 대한슬관절학회
  3. Maurer F, "High tibial osteotomy: does navigation improve results?", Orthopedics, 29(10 Suppl), pp.S130~S132 (2006)
  4. Bae DK, "Closed-wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique", J Bone Joint Surg Br, 91, pp.1164~1171 (2009)
  5. Kim SJ, "Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method : a 1-year retrospective, comparative study", Knee Surg Sports Traumatol Arthrosc, 17, pp.128~134 (2009)
  6. Reising K, "Computer-assisted navigation for the intraoperative assessment of lower limb alignment in high tibial osteotomy can avoid outliers compared with the conventional technique", Knee Surg Sports Traumatol Arthrosc, 21, pp.181~188 (2013)
  7. Hofmann AA, "High tibial osteotomy: use of an osteotomy jig, rigid fixation, and early motion versus conventional surgical technique and cast immobilization", Clin Orthop Relat Res, (271), pp.212~217 (1991)
  8. Heijens E, "The role of navigation in high tibial osteotomy: a study of 50 patients", Orthopedics, 32(10 Suppl), pp.40~43 (2009)
  9. Kendoff D, "Navigated lower limb axis measurements : influence of mechanical weight-bearing simulation", J Orthop Res, 26, pp.553~561 (2008)
  10. Lutzner J, "Reliability of limb alignment measurement for high tibial osteotomy with a navigation system", Eur J Med Res, 14, pp.447~450 (2009)
  11. Yamamoto Y, "Validation of computer-assisted open-wedge high tibial osteotomy using three-dimensional navigation", Orthopedics, 31(10 Suppl 1) (2008)
  12. Kyung BS, "Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs", Am J Sports Med, 41, pp.2368~2374 (2013)
  13. Lee DH, "Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy", Arthroscopy, 28, pp.1842~1850 (2012)
  14. Shaw JA, "Recurrent varus angulation after high tibial osteotomy: an anatomic analysis", Clin Orthop Relat Res, (420), pp.205~212 (2004)
  15. Bae DK, "A newly designed miniplate staple for high tibial osteotomy", Bull Hosp Jt Dis, 56, pp.167~170 (1997)
  16. Fowler JR, "The accuracy of digital radiography in orthopaedic applications", Clin Orthop Relat Res, 469, pp.1781~1784 (2011)
  17. Lachin JM, "The role of measurement reliability in clinical trials", Clin Trials, 1, pp.553~566 (2004)
  18. Chan YH, "Biostatistics 104 : correlational analysis", Singapore Med J, 44, pp.614~619 (2003)
  19. Fujisawa Y, "The effect of high tibial osteotomy on osteoarthritis of the knee : an arthroscopic study of 54 knee joints", Orthop Clin North Am, 10, pp.585~608 (1979)
  20. Ogata K, "Standing radiographs cannot determine the correction in high tibial osteotomy", J Bone Joint Surg Br, 73, pp.927~931 (1991)
  21. Gaasbeek RD, "Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy : a one-year randomised controlled study", Int Orthop, 34, pp.201~207 (2010)
  22. Jakob RP, "Closing wedge osteotomy of the tibial head in treatment of single compartment arthrosis", Orthopade, 33, pp.143~152 (2004)

관련 논문AI추천

Navigated versus Conventional Technique in High Tibial Osteotomy: A Meta­Analysis Focusing on Weight Bearing Effect심재앙, Hyuk Min Kwon, Kyung Wook Nha, Young Gon Na, Young­Soo Shin대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제2호Imageless Navigation Versus Conventional Open Wedge High Tibial Osteotomy: A Meta-Analysis of Comparative Studies양재혁, Gi Won Choi, Hyun-Jung Kim, Jung-Ro Yoon대한슬관절학회 · Knee Surgery and Related Research2016 · 제28권 제1호The influence of computer-assisted surgery experience on the accuracy and precision of the postoperative mechanical axis during computer-assisted lateral closingwedge high tibial osteotomyCheol Hee Park, Dae Kyung Bae, Hyun Woo Lee, Sang Jun Song대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제1호Disparity between Preoperative Target Correction Amount and Postoperative Correction Amount in Open Wedge High Tibial Osteotomy이용석, Eui Soo Lee, O-­Sung Lee대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제2호Surgical accuracy of coronal and sagittal alignment in conventional closed-wedge high tibial osteotomy after computer-assisted surgery experienceCheol Hee Park, Dae Kyung Bae, Sang Jun Song, Se Hwan Park대한슬관절학회 · Knee Surgery and Related Research2023 · 제35권 Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs박용범, 이한준, Jung­Won Lim, Min­Ku Song, Seong Hwan Kim대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제4호

이 간행물의 다른 논문 (12건)