초록

The object of this work is to establish an electrochemical noise(EN) measurement technique combined with a direct current potential drop(DCPD) method for monitoring of localized corrosion cracking of nickel-based alloy, and to analyze its mechanism. The electrochemical current and potential noises were measured under various conditions of applied stress to a compact tension specimen in a simulated primary water chemistry of a pressurized water reactor. The amplitude and frequency of the EN signals were evaluated in both time and frequency domains based on a shot noise theory, and then quantitatively analyzed using statistical Weibull distribution function. From the spectral analysis, the effect of the current application in DCPD was found to be effectively excluded from the EN signals generated from the localized corrosion cracking. With the aid of a microstructural analysis, the relationship between EN signals and the localized corrosion cracking mechanism was investigated by comparing the shape parameter of Weibull distribution of a mean time-to-failure.

Abstract

The object of this work is to establish an electrochemical noise(EN) measurement technique combined with a direct current potential drop(DCPD) method for monitoring of localized corrosion cracking of nickel-based alloy, and to analyze its mechanism. The electrochemical current and potential noises were measured under various conditions of applied stress to a compact tension specimen in a simulated primary water chemistry of a pressurized water reactor. The amplitude and frequency of the EN signals were evaluated in both time and frequency domains based on a shot noise theory, and then quantitatively analyzed using statistical Weibull distribution function. From the spectral analysis, the effect of the current application in DCPD was found to be effectively excluded from the EN signals generated from the localized corrosion cracking. With the aid of a microstructural analysis, the relationship between EN signals and the localized corrosion cracking mechanism was investigated by comparing the shape parameter of Weibull distribution of a mean time-to-failure.

참고문헌 (11)

  1. Expert Panel Report on Proactive Materials Degradation Assessment, "P. L. Andresen", U.S.NR, ~, pp.NUREG (2007), CR-6923
  2. Stress Corrosion Cracking in Light Water Reactors : Good Practices and Lessons Learned, "H. Fujimori", IAEA, ~, pp.NP-T-3.13 (2011)
  3. C. A. Loto, , Corrosion, 43, pp.499~ (1987)
  4. J. Stewart, , Corros. Sci., 33, pp.73~ (1992)
  5. R. A. Cottis, , Corrosion, 57, pp.265~ (2001)
  6. H. A. A. Al-Mazeedi, , Electrochim. Acta, 49, pp.2787~ (2004)
  7. J. M. Sanchez-Amaya, , Corros. Sci., 47, pp.3280~ (2005)
  8. T. Anita, , Corros. Sci., 48, pp.2689~ (2006)
  9. S. W. Kim, , Corros. Sci., 51, pp.191~ (2009)
  10. M. A. Hicks, , Int. Journ. of Fracture, 20, pp.91~ (1982)
  11. W. Nelson, "Applied Life Data Analysis" (1982), John Wiley & Sons