배관 침부식 손상 연속모사 장비 개발 및 실증
Development and demonstration of an erosion-corrosion damage simulation apparatus
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Pipe wall thinning caused by erosion and corrosion can adversely affect the operation of aged nuclear power plants. Some injured workers owing to pipe rupture has been reported and power reduction caused by unexpected pipe damage has been occurred consistently. Therefore, it is important to develop erosion-corrosion damage prediction model and investigate its mechanisms. Especially, liquid droplet impingement erosion(LDIE) is regarded as the main issue of pipe wall thinning management. To investigate LDIE mechanism with corrosion environment, we developed erosion-corrosion damage simulation apparatus and its capability has been verified through the preliminary damage experiment of 6061-Al alloy. The apparatus design has been based on ASTM standard test method, G73-10, that use high-speed rotator and enable to simulate water hammering and droplet impingement. The preliminary test results showed mass loss of 3.2% in conditions of peripheral speed of 110m/s, droplet size of 1mm-diameter, and accumulated time of 3 hours. In this study, the apparatus design revealed feasibility of LDIE damage simulation and provided possibility of accelerated erosion-corrosion damage test by controlling water chemistry.
Abstract
Pipe wall thinning caused by erosion and corrosion can adversely affect the operation of aged nuclear power plants. Some injured workers owing to pipe rupture has been reported and power reduction caused by unexpected pipe damage has been occurred consistently. Therefore, it is important to develop erosion-corrosion damage prediction model and investigate its mechanisms. Especially, liquid droplet impingement erosion(LDIE) is regarded as the main issue of pipe wall thinning management. To investigate LDIE mechanism with corrosion environment, we developed erosion-corrosion damage simulation apparatus and its capability has been verified through the preliminary damage experiment of 6061-Al alloy. The apparatus design has been based on ASTM standard test method, G73-10, that use high-speed rotator and enable to simulate water hammering and droplet impingement. The preliminary test results showed mass loss of 3.2% in conditions of peripheral speed of 110m/s, droplet size of 1mm-diameter, and accumulated time of 3 hours. In this study, the apparatus design revealed feasibility of LDIE damage simulation and provided possibility of accelerated erosion-corrosion damage test by controlling water chemistry.
참고문헌 (11)
- Technical Report, "EPRI", ~, pp.Technical Report 1011231 (2004)
- I. Nishiguchi, , E-journal of Advanced Maintenance, 2, pp.14~24 (2010)
- F. J. Heymann, "ASM handbook 18", 221~ (1992)
- F. J. Heymann, , ASTM Spec. Tech. Publ., 408, pp.70~ (1967)
- P. A. Coulon, , Lubr. Eng., 42(6), pp.357~ (1986)
- "ASTM test standard G32-09", ASTM, ~ (1972)
- "ASTM test standard G73-10", ASTM, ~ (1982)
- "ASTM test standard G134-95", ASTM, ~ (1995)
- "ASME Sec. VIII Div.1", ASME, ~ (1992)
- G. Bertollini, , Opt. Eng., 24, pp.464~ (1985)
- J. F. Ripken, , ASTM Spec. Tech. Publ., 408, pp.3~ (1967)