본문 바로가기
KERD
논문KCI 등재

B-Scan 초음파 측정장비를 이용한 원전 배관 침식손상 검사법 개발

Development of Inspection Methodology for a Nuclear Piping Wall Thinning Caused by Erosion Using Ultrasonic B-Scan Measurement Device

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류금속공학

초록

U.S. Electric Power Research Institute (EPRI) has developed CHECWORKS program and applied it to power plant piping lines since some lines were ruptured by flow-accelerated corrosion (FAC) in 1978. Nowadays the CHECWORKS program has been used to manage pipe wall thinning phenomena caused by FAC. However, various erosion mechanisms can occur in carbon-steel piping. Most common forms of erosion are cavitation, flashing,liquid droplet impingement erosion (LDIE), and Solid Particle Erosion (SPE). Those erosion mechanisms cause pipe wall thinning, leaking, rupturing, and even result in unplanned shutdowns of utilities. Especially, in two phase condition, LDIE damages a wide scope of plant pipelines. Furthermore, LDIE is the major culprit to cause such as power runback by pipe leaking. This paper describes the methodologies that manage wall thinning and also predict LDIE wall thinning area. For this study, current properties of two-phase condition are investigated and LDIE areas are selected. The areas are checked by B-Scan method to detect the effect of wall thinning phenomena.

Abstract

U.S. Electric Power Research Institute (EPRI) has developed CHECWORKS program and applied it to power plant piping lines since some lines were ruptured by flow-accelerated corrosion (FAC) in 1978. Nowadays the CHECWORKS program has been used to manage pipe wall thinning phenomena caused by FAC. However, various erosion mechanisms can occur in carbon-steel piping. Most common forms of erosion are cavitation, flashing,liquid droplet impingement erosion (LDIE), and Solid Particle Erosion (SPE). Those erosion mechanisms cause pipe wall thinning, leaking, rupturing, and even result in unplanned shutdowns of utilities. Especially, in two phase condition, LDIE damages a wide scope of plant pipelines. Furthermore, LDIE is the major culprit to cause such as power runback by pipe leaking. This paper describes the methodologies that manage wall thinning and also predict LDIE wall thinning area. For this study, current properties of two-phase condition are investigated and LDIE areas are selected. The areas are checked by B-Scan method to detect the effect of wall thinning phenomena.

참고문헌 (4)

  1. Recommendations for Controlling Cavitation, Flashing, Flquid Droplet Impingement, and Solid Particl Erosion in Nuclear Power Piping Systems, "Jeffrey Horowitz", EPRI, 3-2~, pp.1011231 (2004)
  2. G. W. Vickers, , Int. J. Mech. Sci, 14, pp.765~ (1972)
  3. Olympus, "EPOCH XT User's Manual, 910-260-EN, Rev. G", 185~ (2011)
  4. Jeffrey Horowitz, "Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R3)", EPRI, 4~ (2006)

관련 논문AI추천